Cargando…

Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test

Laboratory testing for thrombophilia is complicated but essential for diagnosis. In 2017, the cobas® Factor II and Factor V Test (cobas F2F5 test) was launched for use with the cobas z 480 analyzer. This qualitative polymerase chain reaction test enables multiplex Factor II and Factor V testing with...

Descripción completa

Detalles Bibliográficos
Autores principales: Longshore, John W., DeMartin, Kelli, Yu, Karen, Das, Partha, Zhang, Guili, Rehage, Taraneh Tamaddon, Jethwaney, Deepa, Karwowska, Sylwia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6336749/
https://www.ncbi.nlm.nih.gov/pubmed/30284176
http://dx.doi.org/10.1007/s11239-018-1745-8
_version_ 1783388108913377280
author Longshore, John W.
DeMartin, Kelli
Yu, Karen
Das, Partha
Zhang, Guili
Rehage, Taraneh Tamaddon
Jethwaney, Deepa
Karwowska, Sylwia
author_facet Longshore, John W.
DeMartin, Kelli
Yu, Karen
Das, Partha
Zhang, Guili
Rehage, Taraneh Tamaddon
Jethwaney, Deepa
Karwowska, Sylwia
author_sort Longshore, John W.
collection PubMed
description Laboratory testing for thrombophilia is complicated but essential for diagnosis. In 2017, the cobas® Factor II and Factor V Test (cobas F2F5 test) was launched for use with the cobas z 480 analyzer. This qualitative polymerase chain reaction test enables multiplex Factor II and Factor V testing with flexible reporting and workflow efficiency. Here, we report the results from studies investigating the performance of the cobas F2F5 test. Technical performance verification, clinical validation, external laboratory performance, and workflow comparison studies were performed. Fresh and frozen whole-blood and genomic DNA (gDNA) samples were tested, and several manual and automated DNA isolation methods were used. Bidirectional Sanger sequencing was used to verify genotypes identified by the cobas F2F5 test. One hundred percent agreement between the cobas F2F5 test and Sanger sequencing was observed for all genotypes. An external laboratory using remnant clinical samples also yielded 100% agreement between cobas F2F5 test results and their routine testing method. The cobas F2F5 test reduced the total sample processing time compared with the LightCycler® 1.2 platform (98.6 vs 420.2 min; 96 samples). Hemoglobin, extraction buffer, and ethanol contamination of the gDNA sample can lead to invalid results. The cobas F2F5 test has a high degree of accuracy for identification of Factor II and Factor V genotypes. This multiplex testing with short sample processing time can reduce handling errors and increase efficiency. Both manual and automated DNA isolation methods can be used with the cobas F2F5 test. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11239-018-1745-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6336749
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-63367492019-02-01 Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test Longshore, John W. DeMartin, Kelli Yu, Karen Das, Partha Zhang, Guili Rehage, Taraneh Tamaddon Jethwaney, Deepa Karwowska, Sylwia J Thromb Thrombolysis Article Laboratory testing for thrombophilia is complicated but essential for diagnosis. In 2017, the cobas® Factor II and Factor V Test (cobas F2F5 test) was launched for use with the cobas z 480 analyzer. This qualitative polymerase chain reaction test enables multiplex Factor II and Factor V testing with flexible reporting and workflow efficiency. Here, we report the results from studies investigating the performance of the cobas F2F5 test. Technical performance verification, clinical validation, external laboratory performance, and workflow comparison studies were performed. Fresh and frozen whole-blood and genomic DNA (gDNA) samples were tested, and several manual and automated DNA isolation methods were used. Bidirectional Sanger sequencing was used to verify genotypes identified by the cobas F2F5 test. One hundred percent agreement between the cobas F2F5 test and Sanger sequencing was observed for all genotypes. An external laboratory using remnant clinical samples also yielded 100% agreement between cobas F2F5 test results and their routine testing method. The cobas F2F5 test reduced the total sample processing time compared with the LightCycler® 1.2 platform (98.6 vs 420.2 min; 96 samples). Hemoglobin, extraction buffer, and ethanol contamination of the gDNA sample can lead to invalid results. The cobas F2F5 test has a high degree of accuracy for identification of Factor II and Factor V genotypes. This multiplex testing with short sample processing time can reduce handling errors and increase efficiency. Both manual and automated DNA isolation methods can be used with the cobas F2F5 test. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11239-018-1745-8) contains supplementary material, which is available to authorized users. Springer US 2018-10-03 2019 /pmc/articles/PMC6336749/ /pubmed/30284176 http://dx.doi.org/10.1007/s11239-018-1745-8 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Longshore, John W.
DeMartin, Kelli
Yu, Karen
Das, Partha
Zhang, Guili
Rehage, Taraneh Tamaddon
Jethwaney, Deepa
Karwowska, Sylwia
Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test
title Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test
title_full Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test
title_fullStr Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test
title_full_unstemmed Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test
title_short Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test
title_sort multiplex testing for factor ii and factor v mutations in thrombophilia: technical verification and clinical validation of the cobas® factor ii and factor v test
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6336749/
https://www.ncbi.nlm.nih.gov/pubmed/30284176
http://dx.doi.org/10.1007/s11239-018-1745-8
work_keys_str_mv AT longshorejohnw multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest
AT demartinkelli multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest
AT yukaren multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest
AT daspartha multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest
AT zhangguili multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest
AT rehagetaranehtamaddon multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest
AT jethwaneydeepa multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest
AT karwowskasylwia multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest