Cargando…
Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test
Laboratory testing for thrombophilia is complicated but essential for diagnosis. In 2017, the cobas® Factor II and Factor V Test (cobas F2F5 test) was launched for use with the cobas z 480 analyzer. This qualitative polymerase chain reaction test enables multiplex Factor II and Factor V testing with...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6336749/ https://www.ncbi.nlm.nih.gov/pubmed/30284176 http://dx.doi.org/10.1007/s11239-018-1745-8 |
_version_ | 1783388108913377280 |
---|---|
author | Longshore, John W. DeMartin, Kelli Yu, Karen Das, Partha Zhang, Guili Rehage, Taraneh Tamaddon Jethwaney, Deepa Karwowska, Sylwia |
author_facet | Longshore, John W. DeMartin, Kelli Yu, Karen Das, Partha Zhang, Guili Rehage, Taraneh Tamaddon Jethwaney, Deepa Karwowska, Sylwia |
author_sort | Longshore, John W. |
collection | PubMed |
description | Laboratory testing for thrombophilia is complicated but essential for diagnosis. In 2017, the cobas® Factor II and Factor V Test (cobas F2F5 test) was launched for use with the cobas z 480 analyzer. This qualitative polymerase chain reaction test enables multiplex Factor II and Factor V testing with flexible reporting and workflow efficiency. Here, we report the results from studies investigating the performance of the cobas F2F5 test. Technical performance verification, clinical validation, external laboratory performance, and workflow comparison studies were performed. Fresh and frozen whole-blood and genomic DNA (gDNA) samples were tested, and several manual and automated DNA isolation methods were used. Bidirectional Sanger sequencing was used to verify genotypes identified by the cobas F2F5 test. One hundred percent agreement between the cobas F2F5 test and Sanger sequencing was observed for all genotypes. An external laboratory using remnant clinical samples also yielded 100% agreement between cobas F2F5 test results and their routine testing method. The cobas F2F5 test reduced the total sample processing time compared with the LightCycler® 1.2 platform (98.6 vs 420.2 min; 96 samples). Hemoglobin, extraction buffer, and ethanol contamination of the gDNA sample can lead to invalid results. The cobas F2F5 test has a high degree of accuracy for identification of Factor II and Factor V genotypes. This multiplex testing with short sample processing time can reduce handling errors and increase efficiency. Both manual and automated DNA isolation methods can be used with the cobas F2F5 test. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11239-018-1745-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6336749 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-63367492019-02-01 Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test Longshore, John W. DeMartin, Kelli Yu, Karen Das, Partha Zhang, Guili Rehage, Taraneh Tamaddon Jethwaney, Deepa Karwowska, Sylwia J Thromb Thrombolysis Article Laboratory testing for thrombophilia is complicated but essential for diagnosis. In 2017, the cobas® Factor II and Factor V Test (cobas F2F5 test) was launched for use with the cobas z 480 analyzer. This qualitative polymerase chain reaction test enables multiplex Factor II and Factor V testing with flexible reporting and workflow efficiency. Here, we report the results from studies investigating the performance of the cobas F2F5 test. Technical performance verification, clinical validation, external laboratory performance, and workflow comparison studies were performed. Fresh and frozen whole-blood and genomic DNA (gDNA) samples were tested, and several manual and automated DNA isolation methods were used. Bidirectional Sanger sequencing was used to verify genotypes identified by the cobas F2F5 test. One hundred percent agreement between the cobas F2F5 test and Sanger sequencing was observed for all genotypes. An external laboratory using remnant clinical samples also yielded 100% agreement between cobas F2F5 test results and their routine testing method. The cobas F2F5 test reduced the total sample processing time compared with the LightCycler® 1.2 platform (98.6 vs 420.2 min; 96 samples). Hemoglobin, extraction buffer, and ethanol contamination of the gDNA sample can lead to invalid results. The cobas F2F5 test has a high degree of accuracy for identification of Factor II and Factor V genotypes. This multiplex testing with short sample processing time can reduce handling errors and increase efficiency. Both manual and automated DNA isolation methods can be used with the cobas F2F5 test. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11239-018-1745-8) contains supplementary material, which is available to authorized users. Springer US 2018-10-03 2019 /pmc/articles/PMC6336749/ /pubmed/30284176 http://dx.doi.org/10.1007/s11239-018-1745-8 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Article Longshore, John W. DeMartin, Kelli Yu, Karen Das, Partha Zhang, Guili Rehage, Taraneh Tamaddon Jethwaney, Deepa Karwowska, Sylwia Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test |
title | Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test |
title_full | Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test |
title_fullStr | Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test |
title_full_unstemmed | Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test |
title_short | Multiplex testing for Factor II and Factor V mutations in thrombophilia: technical verification and clinical validation of the cobas® Factor II and Factor V test |
title_sort | multiplex testing for factor ii and factor v mutations in thrombophilia: technical verification and clinical validation of the cobas® factor ii and factor v test |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6336749/ https://www.ncbi.nlm.nih.gov/pubmed/30284176 http://dx.doi.org/10.1007/s11239-018-1745-8 |
work_keys_str_mv | AT longshorejohnw multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest AT demartinkelli multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest AT yukaren multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest AT daspartha multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest AT zhangguili multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest AT rehagetaranehtamaddon multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest AT jethwaneydeepa multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest AT karwowskasylwia multiplextestingforfactoriiandfactorvmutationsinthrombophiliatechnicalverificationandclinicalvalidationofthecobasfactoriiandfactorvtest |