Cargando…

Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn’s Disease?

PURPOSE: Monitoring Crohn’s disease (CD) activity has a crucial importance, especially for evaluating treatment efficacy. Magnetic resonance enterography (MRE) and diffusion-weighted imaging (DWI) or their combination may represent potential non-invasive tools for this purpose. This study aimed to e...

Descripción completa

Detalles Bibliográficos
Autores principales: Soydan, Levent, Demir, Ali Aslan, Ozer, Serhat, Ozkara, Selvinaz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ubiquity Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6337050/
https://www.ncbi.nlm.nih.gov/pubmed/30671568
http://dx.doi.org/10.5334/jbsr.1521
_version_ 1783388155180744704
author Soydan, Levent
Demir, Ali Aslan
Ozer, Serhat
Ozkara, Selvinaz
author_facet Soydan, Levent
Demir, Ali Aslan
Ozer, Serhat
Ozkara, Selvinaz
author_sort Soydan, Levent
collection PubMed
description PURPOSE: Monitoring Crohn’s disease (CD) activity has a crucial importance, especially for evaluating treatment efficacy. Magnetic resonance enterography (MRE) and diffusion-weighted imaging (DWI) or their combination may represent potential non-invasive tools for this purpose. This study aimed to examine DWI and MRE for their potential to differentiate between different grades of ileocolonic CD activity. MATERIALS AND METHODS: This retrospective study included 54 adult patients with a diagnosis of CD who underwent ileocolonoscopy and MRE including the DWI sequence. The severity of CD inflammation was categorized by Simple Endoscopic Score for Crohn’s Disease (SES-CD) as inactive, mild, moderate and severe. In addition, following conventional MRE and DWI parameters were examined: bowel wall thickness, mural T2 hyperintensity, contrast enhancement, DWI signal intensity, and apparent diffusion coefficient (ADC) values. RESULTS: In patients with moderate to severe disease based on SES-CD, T2 hyperintensity score [1.68 ± 0.77 (1–3) vs. 2.19 ± 0.69 (1–3); p = 0.013] and mean DWI score [2.42 ± 0.58 (1–3) vs. 2.04 ± 0.69 (1–3); p = 0.037 ] were higher and mean ADC values [1.5 ± 0.4 (0.9–2.5) vs. 1.2 ± 0.3 (0.6–1.8)] were lower compared to patients with inactive to mild CD. ADC had a moderate diagnostic accuracy in predicting moderate to severe disease (AUC = 0.729, 95% CI = 0.591–0.841, p = 0.001), with a cut-off value of ≤1.47 × 10(–3) mm(2)/sec yielded 88.5% (23/26) sensitivity, 57.1% (16/28) specificity. CONCLUSION: DWI, ADC and T2 signal appear to differentiate moderate to severe CD from inactive to mildly active CD, based on SES-CD evaluation and may be useful in monitoring disease activity, particularly when evaluating treatment response.
format Online
Article
Text
id pubmed-6337050
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Ubiquity Press
record_format MEDLINE/PubMed
spelling pubmed-63370502019-01-22 Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn’s Disease? Soydan, Levent Demir, Ali Aslan Ozer, Serhat Ozkara, Selvinaz J Belg Soc Radiol Original Article PURPOSE: Monitoring Crohn’s disease (CD) activity has a crucial importance, especially for evaluating treatment efficacy. Magnetic resonance enterography (MRE) and diffusion-weighted imaging (DWI) or their combination may represent potential non-invasive tools for this purpose. This study aimed to examine DWI and MRE for their potential to differentiate between different grades of ileocolonic CD activity. MATERIALS AND METHODS: This retrospective study included 54 adult patients with a diagnosis of CD who underwent ileocolonoscopy and MRE including the DWI sequence. The severity of CD inflammation was categorized by Simple Endoscopic Score for Crohn’s Disease (SES-CD) as inactive, mild, moderate and severe. In addition, following conventional MRE and DWI parameters were examined: bowel wall thickness, mural T2 hyperintensity, contrast enhancement, DWI signal intensity, and apparent diffusion coefficient (ADC) values. RESULTS: In patients with moderate to severe disease based on SES-CD, T2 hyperintensity score [1.68 ± 0.77 (1–3) vs. 2.19 ± 0.69 (1–3); p = 0.013] and mean DWI score [2.42 ± 0.58 (1–3) vs. 2.04 ± 0.69 (1–3); p = 0.037 ] were higher and mean ADC values [1.5 ± 0.4 (0.9–2.5) vs. 1.2 ± 0.3 (0.6–1.8)] were lower compared to patients with inactive to mild CD. ADC had a moderate diagnostic accuracy in predicting moderate to severe disease (AUC = 0.729, 95% CI = 0.591–0.841, p = 0.001), with a cut-off value of ≤1.47 × 10(–3) mm(2)/sec yielded 88.5% (23/26) sensitivity, 57.1% (16/28) specificity. CONCLUSION: DWI, ADC and T2 signal appear to differentiate moderate to severe CD from inactive to mildly active CD, based on SES-CD evaluation and may be useful in monitoring disease activity, particularly when evaluating treatment response. Ubiquity Press 2019-01-18 /pmc/articles/PMC6337050/ /pubmed/30671568 http://dx.doi.org/10.5334/jbsr.1521 Text en Copyright: © 2019 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC-BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. See http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Soydan, Levent
Demir, Ali Aslan
Ozer, Serhat
Ozkara, Selvinaz
Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn’s Disease?
title Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn’s Disease?
title_full Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn’s Disease?
title_fullStr Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn’s Disease?
title_full_unstemmed Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn’s Disease?
title_short Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn’s Disease?
title_sort can mr enterography and diffusion-weighted imaging predict disease activity assessed by simple endoscopic score for crohn’s disease?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6337050/
https://www.ncbi.nlm.nih.gov/pubmed/30671568
http://dx.doi.org/10.5334/jbsr.1521
work_keys_str_mv AT soydanlevent canmrenterographyanddiffusionweightedimagingpredictdiseaseactivityassessedbysimpleendoscopicscoreforcrohnsdisease
AT demiraliaslan canmrenterographyanddiffusionweightedimagingpredictdiseaseactivityassessedbysimpleendoscopicscoreforcrohnsdisease
AT ozerserhat canmrenterographyanddiffusionweightedimagingpredictdiseaseactivityassessedbysimpleendoscopicscoreforcrohnsdisease
AT ozkaraselvinaz canmrenterographyanddiffusionweightedimagingpredictdiseaseactivityassessedbysimpleendoscopicscoreforcrohnsdisease