Cargando…
Evaluation of Polyvinyl Alcohol/Pectin-Based Hydrogel Disks as Extraction Phase for Determination of Steroidal Hormones in Aqueous Samples by GC-MS/MS
A new extraction phase based on hydrogel disks of polyvinyl alcohol (PVOH) and pectin was proposed, characterized and evaluated for the extraction of six steroidal hormones (estriol, estrone, 17β-estradiol, 17α-ethinylestradiol, progesterone, and testosterone) in aqueous samples with subsequent dete...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6337582/ https://www.ncbi.nlm.nih.gov/pubmed/30583505 http://dx.doi.org/10.3390/molecules24010040 |
_version_ | 1783388288385548288 |
---|---|
author | M. F. M. Sampaio, Naiara D. B. Castilhos, Natara C. da Silva, Bruno C. Riegel-Vidotti, Izabel J. G. Silva, Bruno |
author_facet | M. F. M. Sampaio, Naiara D. B. Castilhos, Natara C. da Silva, Bruno C. Riegel-Vidotti, Izabel J. G. Silva, Bruno |
author_sort | M. F. M. Sampaio, Naiara |
collection | PubMed |
description | A new extraction phase based on hydrogel disks of polyvinyl alcohol (PVOH) and pectin was proposed, characterized and evaluated for the extraction of six steroidal hormones (estriol, estrone, 17β-estradiol, 17α-ethinylestradiol, progesterone, and testosterone) in aqueous samples with subsequent determination by gas chromatography-tandem mass spectrometry (GC-MS/MS) after the derivatization procedure. The developed extraction procedure was based on the solid phase extraction (SPE) technique, but employed hydrogel as the sorbent phase. The effects of several parameters, including the amount and composition of the sorbent phase, pH, sample volume, flow rate, and gel swelling over the extraction efficiency, were evaluated. Gels with lower swelling indexes and larger amounts of sorbent ensured higher extraction yields of analytes. The main benefits of using the PVOH/pectin-based hydrogel as the extraction phase are the ease of synthesis, low-cost preparation, and the possibility of reusing the extraction disks. Limits of quantification of 0.5 μg L(−1) for estrone and 17β-estradiol, and 1 μg L(−1) for testosterone, 17α-ethinylestradiol, progesterone, and estriol were obtained. Accuracy values ranged from 80% to 110%, while the inter-assay precision ranged from 0.23% to 22.2% and the intra-assay from 0.55% to 12.3%. Since the sorbent phase has an amphiphilic character, the use of hydrogels is promising for the extraction of medium-to-high polarity compounds. |
format | Online Article Text |
id | pubmed-6337582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63375822019-01-25 Evaluation of Polyvinyl Alcohol/Pectin-Based Hydrogel Disks as Extraction Phase for Determination of Steroidal Hormones in Aqueous Samples by GC-MS/MS M. F. M. Sampaio, Naiara D. B. Castilhos, Natara C. da Silva, Bruno C. Riegel-Vidotti, Izabel J. G. Silva, Bruno Molecules Article A new extraction phase based on hydrogel disks of polyvinyl alcohol (PVOH) and pectin was proposed, characterized and evaluated for the extraction of six steroidal hormones (estriol, estrone, 17β-estradiol, 17α-ethinylestradiol, progesterone, and testosterone) in aqueous samples with subsequent determination by gas chromatography-tandem mass spectrometry (GC-MS/MS) after the derivatization procedure. The developed extraction procedure was based on the solid phase extraction (SPE) technique, but employed hydrogel as the sorbent phase. The effects of several parameters, including the amount and composition of the sorbent phase, pH, sample volume, flow rate, and gel swelling over the extraction efficiency, were evaluated. Gels with lower swelling indexes and larger amounts of sorbent ensured higher extraction yields of analytes. The main benefits of using the PVOH/pectin-based hydrogel as the extraction phase are the ease of synthesis, low-cost preparation, and the possibility of reusing the extraction disks. Limits of quantification of 0.5 μg L(−1) for estrone and 17β-estradiol, and 1 μg L(−1) for testosterone, 17α-ethinylestradiol, progesterone, and estriol were obtained. Accuracy values ranged from 80% to 110%, while the inter-assay precision ranged from 0.23% to 22.2% and the intra-assay from 0.55% to 12.3%. Since the sorbent phase has an amphiphilic character, the use of hydrogels is promising for the extraction of medium-to-high polarity compounds. MDPI 2018-12-22 /pmc/articles/PMC6337582/ /pubmed/30583505 http://dx.doi.org/10.3390/molecules24010040 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article M. F. M. Sampaio, Naiara D. B. Castilhos, Natara C. da Silva, Bruno C. Riegel-Vidotti, Izabel J. G. Silva, Bruno Evaluation of Polyvinyl Alcohol/Pectin-Based Hydrogel Disks as Extraction Phase for Determination of Steroidal Hormones in Aqueous Samples by GC-MS/MS |
title | Evaluation of Polyvinyl Alcohol/Pectin-Based Hydrogel Disks as Extraction Phase for Determination of Steroidal Hormones in Aqueous Samples by GC-MS/MS |
title_full | Evaluation of Polyvinyl Alcohol/Pectin-Based Hydrogel Disks as Extraction Phase for Determination of Steroidal Hormones in Aqueous Samples by GC-MS/MS |
title_fullStr | Evaluation of Polyvinyl Alcohol/Pectin-Based Hydrogel Disks as Extraction Phase for Determination of Steroidal Hormones in Aqueous Samples by GC-MS/MS |
title_full_unstemmed | Evaluation of Polyvinyl Alcohol/Pectin-Based Hydrogel Disks as Extraction Phase for Determination of Steroidal Hormones in Aqueous Samples by GC-MS/MS |
title_short | Evaluation of Polyvinyl Alcohol/Pectin-Based Hydrogel Disks as Extraction Phase for Determination of Steroidal Hormones in Aqueous Samples by GC-MS/MS |
title_sort | evaluation of polyvinyl alcohol/pectin-based hydrogel disks as extraction phase for determination of steroidal hormones in aqueous samples by gc-ms/ms |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6337582/ https://www.ncbi.nlm.nih.gov/pubmed/30583505 http://dx.doi.org/10.3390/molecules24010040 |
work_keys_str_mv | AT mfmsampaionaiara evaluationofpolyvinylalcoholpectinbasedhydrogeldisksasextractionphasefordeterminationofsteroidalhormonesinaqueoussamplesbygcmsms AT dbcastilhosnatara evaluationofpolyvinylalcoholpectinbasedhydrogeldisksasextractionphasefordeterminationofsteroidalhormonesinaqueoussamplesbygcmsms AT cdasilvabruno evaluationofpolyvinylalcoholpectinbasedhydrogeldisksasextractionphasefordeterminationofsteroidalhormonesinaqueoussamplesbygcmsms AT criegelvidottiizabel evaluationofpolyvinylalcoholpectinbasedhydrogeldisksasextractionphasefordeterminationofsteroidalhormonesinaqueoussamplesbygcmsms AT jgsilvabruno evaluationofpolyvinylalcoholpectinbasedhydrogeldisksasextractionphasefordeterminationofsteroidalhormonesinaqueoussamplesbygcmsms |