Analytical Model for Load–Slip Relationship of Perfobond Shear Connector Based on Push-Out Test
In composite structures, the perfobond connector is an alternative type of shear connector which consists of a steel plate with a certain number of holes. The load–slip relationship is critical for structural analysis and numerical simulation of composite structures using perfobond connectors. In th...
Autores principales: | Zheng, Shuangjie, Zhao, Chen, Liu, Yangqing |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6337733/ https://www.ncbi.nlm.nih.gov/pubmed/30577672 http://dx.doi.org/10.3390/ma12010029 |
Ejemplares similares
-
Experimental and Numerical Study on Shear Resistance of Notched Perfobond Shear Connector
por: Zheng, Shuangjie, et al.
Publicado: (2019) -
Experimental and Numerical Evaluation on the Performance of Perfobond Leiste Shear Connectors in Steel–SFRCC Composite Beams
por: Peng, Kai, et al.
Publicado: (2022) -
Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
por: Kim, Sang-Hyo, et al.
Publicado: (2017) -
Experimental Study on the Mechanical Properties of Perfobond Rib Shear Connectors with Steel Fiber High Strength Concrete
por: Wu, Fangwen, et al.
Publicado: (2021) -
A Trilinear Model for the Load–Slip Behavior of Headed Stud Shear Connectors
por: Meng, Hao, et al.
Publicado: (2023)