Cargando…

Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems

Full-field transmission X-ray microscopy (TXM) is a well established technique, available at various synchrotron beamlines around the world as well as by laboratory benchtop devices. One of the major TXM challenges, due to its nanometre-scale resolution, is the overall instrument stability during th...

Descripción completa

Detalles Bibliográficos
Autores principales: Larsson, Emanuel, Gürsoy, Doğa, De Carlo, Francesco, Lilleodden, Erica, Storm, Malte, Wilde, Fabian, Hu, Kaixiong, Müller, Martin, Greving, Imke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6337890/
https://www.ncbi.nlm.nih.gov/pubmed/30655485
http://dx.doi.org/10.1107/S1600577518015242
_version_ 1783388353858633728
author Larsson, Emanuel
Gürsoy, Doğa
De Carlo, Francesco
Lilleodden, Erica
Storm, Malte
Wilde, Fabian
Hu, Kaixiong
Müller, Martin
Greving, Imke
author_facet Larsson, Emanuel
Gürsoy, Doğa
De Carlo, Francesco
Lilleodden, Erica
Storm, Malte
Wilde, Fabian
Hu, Kaixiong
Müller, Martin
Greving, Imke
author_sort Larsson, Emanuel
collection PubMed
description Full-field transmission X-ray microscopy (TXM) is a well established technique, available at various synchrotron beamlines around the world as well as by laboratory benchtop devices. One of the major TXM challenges, due to its nanometre-scale resolution, is the overall instrument stability during the acquisition of the series of tomographic projections. The ability to correct for vertical and horizontal distortions of each projection image during acquisition is necessary in order to achieve the effective 3D spatial resolution. The effectiveness of such an image alignment is also heavily influenced by the absorption properties and strong contrast of specific features in the scanned sample. Here it is shown that nanoporous gold (NPG) can be used as an ideal 3D test pattern for evaluating and optimizing the performance of a TXM instrument for hard X-rays at a synchrotron beamline. Unique features of NPG, such as hierarchical structures at multiple length scales and high absorbing capabilities, makes it an ideal choice for characterization, which involves a combination of a rapid-alignment algorithm applied on the acquired projections followed by the extraction of a set of both 2D- and 3D-descriptive image parameters. This protocol can be used for comparing the efficiency of TXM instruments at different synchrotron beamlines in the world or benchtop devices, based on a reference library of scanned NPG samples, containing information about the estimated horizontal and vertical alignment values, 2D qualitative parameters and quantitative 3D parameters. The possibility to tailor the ligament sizes of NPG to match the achievable resolution in combination with the high electron density of gold makes NPG an ideal 3D test pattern for evaluating the status and performance of a given synchrotron-based or benchtop-based TXM setup.
format Online
Article
Text
id pubmed-6337890
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-63378902019-02-01 Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems Larsson, Emanuel Gürsoy, Doğa De Carlo, Francesco Lilleodden, Erica Storm, Malte Wilde, Fabian Hu, Kaixiong Müller, Martin Greving, Imke J Synchrotron Radiat Research Papers Full-field transmission X-ray microscopy (TXM) is a well established technique, available at various synchrotron beamlines around the world as well as by laboratory benchtop devices. One of the major TXM challenges, due to its nanometre-scale resolution, is the overall instrument stability during the acquisition of the series of tomographic projections. The ability to correct for vertical and horizontal distortions of each projection image during acquisition is necessary in order to achieve the effective 3D spatial resolution. The effectiveness of such an image alignment is also heavily influenced by the absorption properties and strong contrast of specific features in the scanned sample. Here it is shown that nanoporous gold (NPG) can be used as an ideal 3D test pattern for evaluating and optimizing the performance of a TXM instrument for hard X-rays at a synchrotron beamline. Unique features of NPG, such as hierarchical structures at multiple length scales and high absorbing capabilities, makes it an ideal choice for characterization, which involves a combination of a rapid-alignment algorithm applied on the acquired projections followed by the extraction of a set of both 2D- and 3D-descriptive image parameters. This protocol can be used for comparing the efficiency of TXM instruments at different synchrotron beamlines in the world or benchtop devices, based on a reference library of scanned NPG samples, containing information about the estimated horizontal and vertical alignment values, 2D qualitative parameters and quantitative 3D parameters. The possibility to tailor the ligament sizes of NPG to match the achievable resolution in combination with the high electron density of gold makes NPG an ideal 3D test pattern for evaluating the status and performance of a given synchrotron-based or benchtop-based TXM setup. International Union of Crystallography 2019-01-01 /pmc/articles/PMC6337890/ /pubmed/30655485 http://dx.doi.org/10.1107/S1600577518015242 Text en © Emanuel Larsson et al. 2019 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.http://creativecommons.org/licenses/by/2.0/uk/
spellingShingle Research Papers
Larsson, Emanuel
Gürsoy, Doğa
De Carlo, Francesco
Lilleodden, Erica
Storm, Malte
Wilde, Fabian
Hu, Kaixiong
Müller, Martin
Greving, Imke
Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems
title Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems
title_full Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems
title_fullStr Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems
title_full_unstemmed Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems
title_short Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems
title_sort nanoporous gold: a hierarchical and multiscale 3d test pattern for characterizing x-ray nano-tomography systems
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6337890/
https://www.ncbi.nlm.nih.gov/pubmed/30655485
http://dx.doi.org/10.1107/S1600577518015242
work_keys_str_mv AT larssonemanuel nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems
AT gursoydoga nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems
AT decarlofrancesco nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems
AT lilleoddenerica nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems
AT stormmalte nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems
AT wildefabian nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems
AT hukaixiong nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems
AT mullermartin nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems
AT grevingimke nanoporousgoldahierarchicalandmultiscale3dtestpatternforcharacterizingxraynanotomographysystems