Cargando…

Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool

This paper proposes a system utilizing a Renishaw XL80 positioning error measuring interferometer and sensitivity analysis design to measure six-degree-of-freedom (6 DOF) geometric errors of a machine tool’s linear guide. Each error is characterized by high independence with significantly reduced cr...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Chien-Sheng, Lai, Jia-Jun, Luo, Yong-Tai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6339122/
https://www.ncbi.nlm.nih.gov/pubmed/30577462
http://dx.doi.org/10.3390/s19010005
_version_ 1783388565430861824
author Liu, Chien-Sheng
Lai, Jia-Jun
Luo, Yong-Tai
author_facet Liu, Chien-Sheng
Lai, Jia-Jun
Luo, Yong-Tai
author_sort Liu, Chien-Sheng
collection PubMed
description This paper proposes a system utilizing a Renishaw XL80 positioning error measuring interferometer and sensitivity analysis design to measure six-degree-of-freedom (6 DOF) geometric errors of a machine tool’s linear guide. Each error is characterized by high independence with significantly reduced crosstalk, and error calculations are extremely fast and accurate. Initially, the real light path was simulated using Zemax. Then, Matlab’s skew ray tracing method was used to perform mathematical modeling and ray matching. Each error’s sensitivity to the sensor was then analyzed, and curve fitting was used to simplify and speed up the mathematical model computations. Finally, Solidworks was used to design the set of system modules, bringing the proposed system closer to a product. This system measured actual 6 DOF geometric errors of a machine tool’s linear guide, and a comparison is made with the Renishaw XL-80 interferometer measurements. The resulting pitch, yaw, horizontal straightness, and vertical straightness error deviation ranges are ±0.5 arcsec, ±3.6 arcsec, ±2.1 μm, and ±2.3 μm, respectively. The maximum repeatability deviations for the measured guide’s pitch, yaw, roll, horizontal straightness, vertical straightness, and positioning errors are 0.4 arcsec, 0.2 arcsec, 4.2 arcsec, 1.5 μm, 0.3 μm, and 3 μm, respectively.
format Online
Article
Text
id pubmed-6339122
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63391222019-01-23 Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool Liu, Chien-Sheng Lai, Jia-Jun Luo, Yong-Tai Sensors (Basel) Article This paper proposes a system utilizing a Renishaw XL80 positioning error measuring interferometer and sensitivity analysis design to measure six-degree-of-freedom (6 DOF) geometric errors of a machine tool’s linear guide. Each error is characterized by high independence with significantly reduced crosstalk, and error calculations are extremely fast and accurate. Initially, the real light path was simulated using Zemax. Then, Matlab’s skew ray tracing method was used to perform mathematical modeling and ray matching. Each error’s sensitivity to the sensor was then analyzed, and curve fitting was used to simplify and speed up the mathematical model computations. Finally, Solidworks was used to design the set of system modules, bringing the proposed system closer to a product. This system measured actual 6 DOF geometric errors of a machine tool’s linear guide, and a comparison is made with the Renishaw XL-80 interferometer measurements. The resulting pitch, yaw, horizontal straightness, and vertical straightness error deviation ranges are ±0.5 arcsec, ±3.6 arcsec, ±2.1 μm, and ±2.3 μm, respectively. The maximum repeatability deviations for the measured guide’s pitch, yaw, roll, horizontal straightness, vertical straightness, and positioning errors are 0.4 arcsec, 0.2 arcsec, 4.2 arcsec, 1.5 μm, 0.3 μm, and 3 μm, respectively. MDPI 2018-12-20 /pmc/articles/PMC6339122/ /pubmed/30577462 http://dx.doi.org/10.3390/s19010005 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Chien-Sheng
Lai, Jia-Jun
Luo, Yong-Tai
Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool
title Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool
title_full Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool
title_fullStr Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool
title_full_unstemmed Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool
title_short Design of a Measurement System for Six-Degree-of-Freedom Geometric Errors of a Linear Guide of a Machine Tool
title_sort design of a measurement system for six-degree-of-freedom geometric errors of a linear guide of a machine tool
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6339122/
https://www.ncbi.nlm.nih.gov/pubmed/30577462
http://dx.doi.org/10.3390/s19010005
work_keys_str_mv AT liuchiensheng designofameasurementsystemforsixdegreeoffreedomgeometricerrorsofalinearguideofamachinetool
AT laijiajun designofameasurementsystemforsixdegreeoffreedomgeometricerrorsofalinearguideofamachinetool
AT luoyongtai designofameasurementsystemforsixdegreeoffreedomgeometricerrorsofalinearguideofamachinetool