Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography

Motion analysis of the thumb and the four fingers during human gripping of a cylindrical object is a prerequisite for designing motion mechanisms in electronic arm prostheses and robotic hands. Conventional measurement methods include the use of angle sensors or multiple video recording of markers....

Descripción completa

Detalles Bibliográficos
Autores principales: Shimawaki, Satoshi, Murai, Takuma, Nakabayashi, Masataka, Sugimoto, Hideharu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6339738/
https://www.ncbi.nlm.nih.gov/pubmed/30723529
http://dx.doi.org/10.1155/2019/2839648
_version_ 1783388681167437824
author Shimawaki, Satoshi
Murai, Takuma
Nakabayashi, Masataka
Sugimoto, Hideharu
author_facet Shimawaki, Satoshi
Murai, Takuma
Nakabayashi, Masataka
Sugimoto, Hideharu
author_sort Shimawaki, Satoshi
collection PubMed
description Motion analysis of the thumb and the four fingers during human gripping of a cylindrical object is a prerequisite for designing motion mechanisms in electronic arm prostheses and robotic hands. Conventional measurement methods include the use of angle sensors or multiple video recording of markers. In the present study, we performed X-ray computed tomography (CT) imaging on fingers gripping cylinders of three different diameters (10, 60, and 120 mm) and constructed a bone model based on these CT images to directly measure the flexion angle of each finger joint. We then compared the results with the flexion angles of joints measured using other methods. The subjects comprised 10 Japanese men with no hand injuries or diseases. Our results showed that smaller cylinder diameters were associated with significant increases in the flexion angle of all the joints of the four fingers. When focusing on the distal interphalangeal joint (DIP), there was no significant difference between any of the fingers for each of the cylinders, except between the index and middle fingers for the 10 mm-diameter cylinder. When focusing on the 10 mm-diameter cylinder, the flexion angle of the proximal interphalangeal joint (PIP) of each finger was significantly larger than that of the DIP and metacarpophalangeal joint (MP). However, no such significant difference was noted for the 120 mm-diameter cylinder. The coupling ratio (CR), which is the ratio of the flexion angles of the DIP and PIP, was significantly smaller for the 10 mm-diameter cylinder than for the 60 mm-diameter cylinder. However, there were no significant differences in CR between any of the fingers. A comparison of our study results with those derived using other methods indicated quantitative consistency for the DIP and PIP. However, for the MP, we noted differences that may be explained by the difficulty in determining the longitudinal axis of the metacarpal using other methods.
format Online
Article
Text
id pubmed-6339738
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-63397382019-02-05 Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography Shimawaki, Satoshi Murai, Takuma Nakabayashi, Masataka Sugimoto, Hideharu Appl Bionics Biomech Research Article Motion analysis of the thumb and the four fingers during human gripping of a cylindrical object is a prerequisite for designing motion mechanisms in electronic arm prostheses and robotic hands. Conventional measurement methods include the use of angle sensors or multiple video recording of markers. In the present study, we performed X-ray computed tomography (CT) imaging on fingers gripping cylinders of three different diameters (10, 60, and 120 mm) and constructed a bone model based on these CT images to directly measure the flexion angle of each finger joint. We then compared the results with the flexion angles of joints measured using other methods. The subjects comprised 10 Japanese men with no hand injuries or diseases. Our results showed that smaller cylinder diameters were associated with significant increases in the flexion angle of all the joints of the four fingers. When focusing on the distal interphalangeal joint (DIP), there was no significant difference between any of the fingers for each of the cylinders, except between the index and middle fingers for the 10 mm-diameter cylinder. When focusing on the 10 mm-diameter cylinder, the flexion angle of the proximal interphalangeal joint (PIP) of each finger was significantly larger than that of the DIP and metacarpophalangeal joint (MP). However, no such significant difference was noted for the 120 mm-diameter cylinder. The coupling ratio (CR), which is the ratio of the flexion angles of the DIP and PIP, was significantly smaller for the 10 mm-diameter cylinder than for the 60 mm-diameter cylinder. However, there were no significant differences in CR between any of the fingers. A comparison of our study results with those derived using other methods indicated quantitative consistency for the DIP and PIP. However, for the MP, we noted differences that may be explained by the difficulty in determining the longitudinal axis of the metacarpal using other methods. Hindawi 2019-01-06 /pmc/articles/PMC6339738/ /pubmed/30723529 http://dx.doi.org/10.1155/2019/2839648 Text en Copyright © 2019 Satoshi Shimawaki et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Shimawaki, Satoshi
Murai, Takuma
Nakabayashi, Masataka
Sugimoto, Hideharu
Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography
title Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography
title_full Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography
title_fullStr Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography
title_full_unstemmed Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography
title_short Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography
title_sort measurement of flexion angle of the finger joint during cylinder gripping using a three-dimensional bone model built by x-ray computed tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6339738/
https://www.ncbi.nlm.nih.gov/pubmed/30723529
http://dx.doi.org/10.1155/2019/2839648
work_keys_str_mv AT shimawakisatoshi measurementofflexionangleofthefingerjointduringcylindergrippingusingathreedimensionalbonemodelbuiltbyxraycomputedtomography
AT muraitakuma measurementofflexionangleofthefingerjointduringcylindergrippingusingathreedimensionalbonemodelbuiltbyxraycomputedtomography
AT nakabayashimasataka measurementofflexionangleofthefingerjointduringcylindergrippingusingathreedimensionalbonemodelbuiltbyxraycomputedtomography
AT sugimotohideharu measurementofflexionangleofthefingerjointduringcylindergrippingusingathreedimensionalbonemodelbuiltbyxraycomputedtomography