Cargando…

Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions

AIM: The aim of this in vitro study was to comparatively evaluate the effect of chemical disinfectants on the surface detail reproduction, dimensional stability and surface texture of polyvinyl siloxane (PVS) impressions. MATERIALS AND METHODS: The impressions were then divided into five groups (fif...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahalakshmi, A. S., Jeyapalan, Vidhya, Mahadevan, Vallabh, Krishnan, Chitra Shankar, Azhagarasan, N. S., Ramakrishnan, Hariharan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6340083/
https://www.ncbi.nlm.nih.gov/pubmed/30745752
http://dx.doi.org/10.4103/jips.jips_72_18
_version_ 1783388735460605952
author Mahalakshmi, A. S.
Jeyapalan, Vidhya
Mahadevan, Vallabh
Krishnan, Chitra Shankar
Azhagarasan, N. S.
Ramakrishnan, Hariharan
author_facet Mahalakshmi, A. S.
Jeyapalan, Vidhya
Mahadevan, Vallabh
Krishnan, Chitra Shankar
Azhagarasan, N. S.
Ramakrishnan, Hariharan
author_sort Mahalakshmi, A. S.
collection PubMed
description AIM: The aim of this in vitro study was to comparatively evaluate the effect of chemical disinfectants on the surface detail reproduction, dimensional stability and surface texture of polyvinyl siloxane (PVS) impressions. MATERIALS AND METHODS: The impressions were then divided into five groups (fifteen samples per group) and subjected to a ten minutes immersion with 2% glutaraldehyde (Group I), 1% sodium hypochlorite (Group II), freshly prepared electrolyzed oxidizing water (EOW) with different pH values - acidic (Group III), alkali (Group IV) and neutral (Group V). The samples were examined pre and post-immersion under visual observation for surface detail reproduction, travelling microscope for measurement of dimensional stability and surface profilometer (3D) for evaluation of surface texture. A standardized master die was fabricated and seventy-five PVS test samples were made. The samples were subjected to immersion disinfection and studied for surface detail reproduction, dimensional stability and surface texture. Post-hoc test, paired t test and ANOVA were used to analyze dimensional stability statistically both within and between the test groups. RESULTS: The surface detail reproduction was satisfactory with both pre and post-immersion test samples. A statistically significant dimensional change was observed post-immersion in Groups II, III and V test samples and a statistically insignificant dimensional change was observed in Groups I and IV test samples. There was a negligible change in surface texture post-immersion in Groups I, III, IV and V test samples with a slight increase in surface roughness post-immersion in Group II samples. CONCLUSION: In this study, all the test disinfectants produced satisfactory surface detail reproduction on Polyvinyl siloxane impressions. 2% glutaraldehyde and electrolyzed oxidizing water (alkali) have resulted in statistically insignificant dimensional change, while 1% sodium hypochlorite, electrolyzed oxidizing water (acidic) and electrolyzed oxidizing water (neutral) have resulted in statistically significant dimensional changes. All the test disinfectants except 1% sodium hypochlorite showed a reduction in surface roughness (Ra) values.
format Online
Article
Text
id pubmed-6340083
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-63400832020-01-01 Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions Mahalakshmi, A. S. Jeyapalan, Vidhya Mahadevan, Vallabh Krishnan, Chitra Shankar Azhagarasan, N. S. Ramakrishnan, Hariharan J Indian Prosthodont Soc Original Article AIM: The aim of this in vitro study was to comparatively evaluate the effect of chemical disinfectants on the surface detail reproduction, dimensional stability and surface texture of polyvinyl siloxane (PVS) impressions. MATERIALS AND METHODS: The impressions were then divided into five groups (fifteen samples per group) and subjected to a ten minutes immersion with 2% glutaraldehyde (Group I), 1% sodium hypochlorite (Group II), freshly prepared electrolyzed oxidizing water (EOW) with different pH values - acidic (Group III), alkali (Group IV) and neutral (Group V). The samples were examined pre and post-immersion under visual observation for surface detail reproduction, travelling microscope for measurement of dimensional stability and surface profilometer (3D) for evaluation of surface texture. A standardized master die was fabricated and seventy-five PVS test samples were made. The samples were subjected to immersion disinfection and studied for surface detail reproduction, dimensional stability and surface texture. Post-hoc test, paired t test and ANOVA were used to analyze dimensional stability statistically both within and between the test groups. RESULTS: The surface detail reproduction was satisfactory with both pre and post-immersion test samples. A statistically significant dimensional change was observed post-immersion in Groups II, III and V test samples and a statistically insignificant dimensional change was observed in Groups I and IV test samples. There was a negligible change in surface texture post-immersion in Groups I, III, IV and V test samples with a slight increase in surface roughness post-immersion in Group II samples. CONCLUSION: In this study, all the test disinfectants produced satisfactory surface detail reproduction on Polyvinyl siloxane impressions. 2% glutaraldehyde and electrolyzed oxidizing water (alkali) have resulted in statistically insignificant dimensional change, while 1% sodium hypochlorite, electrolyzed oxidizing water (acidic) and electrolyzed oxidizing water (neutral) have resulted in statistically significant dimensional changes. All the test disinfectants except 1% sodium hypochlorite showed a reduction in surface roughness (Ra) values. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6340083/ /pubmed/30745752 http://dx.doi.org/10.4103/jips.jips_72_18 Text en Copyright: © 2019 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Mahalakshmi, A. S.
Jeyapalan, Vidhya
Mahadevan, Vallabh
Krishnan, Chitra Shankar
Azhagarasan, N. S.
Ramakrishnan, Hariharan
Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions
title Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions
title_full Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions
title_fullStr Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions
title_full_unstemmed Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions
title_short Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions
title_sort comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and surface texture of poly vinyl siloxane impressions
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6340083/
https://www.ncbi.nlm.nih.gov/pubmed/30745752
http://dx.doi.org/10.4103/jips.jips_72_18
work_keys_str_mv AT mahalakshmias comparativeevaluationoftheeffectofelectrolyzedoxidizingwateronsurfacedetailreproductiondimensionalstabilityandsurfacetextureofpolyvinylsiloxaneimpressions
AT jeyapalanvidhya comparativeevaluationoftheeffectofelectrolyzedoxidizingwateronsurfacedetailreproductiondimensionalstabilityandsurfacetextureofpolyvinylsiloxaneimpressions
AT mahadevanvallabh comparativeevaluationoftheeffectofelectrolyzedoxidizingwateronsurfacedetailreproductiondimensionalstabilityandsurfacetextureofpolyvinylsiloxaneimpressions
AT krishnanchitrashankar comparativeevaluationoftheeffectofelectrolyzedoxidizingwateronsurfacedetailreproductiondimensionalstabilityandsurfacetextureofpolyvinylsiloxaneimpressions
AT azhagarasanns comparativeevaluationoftheeffectofelectrolyzedoxidizingwateronsurfacedetailreproductiondimensionalstabilityandsurfacetextureofpolyvinylsiloxaneimpressions
AT ramakrishnanhariharan comparativeevaluationoftheeffectofelectrolyzedoxidizingwateronsurfacedetailreproductiondimensionalstabilityandsurfacetextureofpolyvinylsiloxaneimpressions