Cargando…
Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study
BACKGROUND: To determine and compare the force-deflection values of different types of nickel-titanium (NiTi) wires during unloading phase at varying deflections, that is 1 mm, 1.5 mm, 2 mm, and 2.5 mm, with the use of self-ligating ceramic brackets using modified bending test on a typodont under co...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6340216/ https://www.ncbi.nlm.nih.gov/pubmed/30745911 |
_version_ | 1783388761917227008 |
---|---|
author | Tikku, Tripti Khanna, Rohit Agarwal, Akhil Srivastava, Kamna Shekhar, Shashank Shukla, Ivy |
author_facet | Tikku, Tripti Khanna, Rohit Agarwal, Akhil Srivastava, Kamna Shekhar, Shashank Shukla, Ivy |
author_sort | Tikku, Tripti |
collection | PubMed |
description | BACKGROUND: To determine and compare the force-deflection values of different types of nickel-titanium (NiTi) wires during unloading phase at varying deflections, that is 1 mm, 1.5 mm, 2 mm, and 2.5 mm, with the use of self-ligating ceramic brackets using modified bending test on a typodont under controlled temperature conditions. MATERIALS AND METHODS: In this in vitro study total of 45 wires of ovoid shape of three different NiTi wires – pseudoelastic NiTi (Group I), heat activated NiTi (Group II), and esthetic coated NiTi (Group III) for maxillary arch were tested after insertion in ceramic self-ligating brackets bonded to plastic teeth of phantom jaw. The maxillary left lateral incisor was removed to simulate a malpositioned tooth which acted as the load site, and load-deflection characteristics were measured during unloading using Instron, and data analyzed statically by two-way analysis of variance, Tukey's post hoc test, intraclass correlation coefficient and Pearson correlation coefficient. A two-sided (α = 2) P < 0.05 was considered statistically significant. RESULTS: When wires were compared at each deflection statistically significant difference was observed between the three groups of wires (Group I > Group II > Group III) at all the four levels of deflection except for Group II versus Group III at 1 mm, 1.5 mm, and 2 mm of deflection. Statistically significant difference was noted in mean load values for comparisons made at different deflections for each wire except for the comparison made at 1.5 versus 2 mm for Group II and Group III. CONCLUSION: Overall comparison showed esthetic coated Ni-Ti wires gave significantly lower mean load values, followed by heat activated and pseudoelastic NiTi wires. Thus, heat activated NiTi wires are best suited in patients with severe malpositions/periodontitis, while for esthetically conscious patients esthetic coated NiTi can be used. |
format | Online Article Text |
id | pubmed-6340216 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-63402162019-02-11 Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study Tikku, Tripti Khanna, Rohit Agarwal, Akhil Srivastava, Kamna Shekhar, Shashank Shukla, Ivy Dent Res J (Isfahan) Original Article BACKGROUND: To determine and compare the force-deflection values of different types of nickel-titanium (NiTi) wires during unloading phase at varying deflections, that is 1 mm, 1.5 mm, 2 mm, and 2.5 mm, with the use of self-ligating ceramic brackets using modified bending test on a typodont under controlled temperature conditions. MATERIALS AND METHODS: In this in vitro study total of 45 wires of ovoid shape of three different NiTi wires – pseudoelastic NiTi (Group I), heat activated NiTi (Group II), and esthetic coated NiTi (Group III) for maxillary arch were tested after insertion in ceramic self-ligating brackets bonded to plastic teeth of phantom jaw. The maxillary left lateral incisor was removed to simulate a malpositioned tooth which acted as the load site, and load-deflection characteristics were measured during unloading using Instron, and data analyzed statically by two-way analysis of variance, Tukey's post hoc test, intraclass correlation coefficient and Pearson correlation coefficient. A two-sided (α = 2) P < 0.05 was considered statistically significant. RESULTS: When wires were compared at each deflection statistically significant difference was observed between the three groups of wires (Group I > Group II > Group III) at all the four levels of deflection except for Group II versus Group III at 1 mm, 1.5 mm, and 2 mm of deflection. Statistically significant difference was noted in mean load values for comparisons made at different deflections for each wire except for the comparison made at 1.5 versus 2 mm for Group II and Group III. CONCLUSION: Overall comparison showed esthetic coated Ni-Ti wires gave significantly lower mean load values, followed by heat activated and pseudoelastic NiTi wires. Thus, heat activated NiTi wires are best suited in patients with severe malpositions/periodontitis, while for esthetically conscious patients esthetic coated NiTi can be used. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6340216/ /pubmed/30745911 Text en Copyright: © 2019 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Tikku, Tripti Khanna, Rohit Agarwal, Akhil Srivastava, Kamna Shekhar, Shashank Shukla, Ivy Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study |
title | Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study |
title_full | Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study |
title_fullStr | Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study |
title_full_unstemmed | Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study |
title_short | Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study |
title_sort | load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6340216/ https://www.ncbi.nlm.nih.gov/pubmed/30745911 |
work_keys_str_mv | AT tikkutripti loaddeflectioncharacteristicsofcoatedandnoncoatednickeltitaniumwiresinselfligatingbracketsusingamodifiedbendingtestaninvitrostudy AT khannarohit loaddeflectioncharacteristicsofcoatedandnoncoatednickeltitaniumwiresinselfligatingbracketsusingamodifiedbendingtestaninvitrostudy AT agarwalakhil loaddeflectioncharacteristicsofcoatedandnoncoatednickeltitaniumwiresinselfligatingbracketsusingamodifiedbendingtestaninvitrostudy AT srivastavakamna loaddeflectioncharacteristicsofcoatedandnoncoatednickeltitaniumwiresinselfligatingbracketsusingamodifiedbendingtestaninvitrostudy AT shekharshashank loaddeflectioncharacteristicsofcoatedandnoncoatednickeltitaniumwiresinselfligatingbracketsusingamodifiedbendingtestaninvitrostudy AT shuklaivy loaddeflectioncharacteristicsofcoatedandnoncoatednickeltitaniumwiresinselfligatingbracketsusingamodifiedbendingtestaninvitrostudy |