Cargando…

Analysis of reciprocating system real-time torque variation during root canal preparation

OBJECTIVE: This study monitored real-time torque variation of the WaveOne Gold (WOG) and Reciproc Blue (RB) during root canal preparation of mandibular molars. Thirty-six mandibular molars were prepared with WOG Primary 25.07 (WOGP, n = 36) and the RB R25 25.08 (RBR25, n = 36) for the mesial canals,...

Descripción completa

Detalles Bibliográficos
Autores principales: Baratto-Filho, Flares, de Freitas, Jéssica Vavassori, Gabardo, Marilisa Carneiro Leão, Tomazinho, Flávia Sens Fagundes, Mazzi-Chaves, Jardel Francisco, de Sousa-Neto, Manoel Damião
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6341548/
https://www.ncbi.nlm.nih.gov/pubmed/30665455
http://dx.doi.org/10.1186/s13104-019-4080-z
_version_ 1783388961998110720
author Baratto-Filho, Flares
de Freitas, Jéssica Vavassori
Gabardo, Marilisa Carneiro Leão
Tomazinho, Flávia Sens Fagundes
Mazzi-Chaves, Jardel Francisco
de Sousa-Neto, Manoel Damião
author_facet Baratto-Filho, Flares
de Freitas, Jéssica Vavassori
Gabardo, Marilisa Carneiro Leão
Tomazinho, Flávia Sens Fagundes
Mazzi-Chaves, Jardel Francisco
de Sousa-Neto, Manoel Damião
author_sort Baratto-Filho, Flares
collection PubMed
description OBJECTIVE: This study monitored real-time torque variation of the WaveOne Gold (WOG) and Reciproc Blue (RB) during root canal preparation of mandibular molars. Thirty-six mandibular molars were prepared with WOG Primary 25.07 (WOGP, n = 36) and the RB R25 25.08 (RBR25, n = 36) for the mesial canals, whereas WOG Large 45.05 (WOGL, n = 18) and RB R40 40.06 (RBR40, n = 18) for the distal. Canal preparation was divided into thirds and the torque, maximum torque and time, were recorded. RESULTS: The RBR25 instruments exhibited higher maximum torque in the apical third in contrast to the WOGP instruments (p < 0.05). The intragroup analysis found a significant difference in maximum torque between the cervical and apical thirds, and the middle and apical thirds (p < 0.05) for both instruments (RBR25 and WOGP). The WOGP group had the shortest preparation time (p < 0.05). There were no significant differences between the WOGL and RBR40 for any of the parameters evaluated (p > 0.05). The RBR25 had the highest torque when compared to the WOGP. Both instruments exhibited higher torque in the apical third and there were no significant differences between the instruments in the distal canal.
format Online
Article
Text
id pubmed-6341548
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63415482019-01-24 Analysis of reciprocating system real-time torque variation during root canal preparation Baratto-Filho, Flares de Freitas, Jéssica Vavassori Gabardo, Marilisa Carneiro Leão Tomazinho, Flávia Sens Fagundes Mazzi-Chaves, Jardel Francisco de Sousa-Neto, Manoel Damião BMC Res Notes Research Note OBJECTIVE: This study monitored real-time torque variation of the WaveOne Gold (WOG) and Reciproc Blue (RB) during root canal preparation of mandibular molars. Thirty-six mandibular molars were prepared with WOG Primary 25.07 (WOGP, n = 36) and the RB R25 25.08 (RBR25, n = 36) for the mesial canals, whereas WOG Large 45.05 (WOGL, n = 18) and RB R40 40.06 (RBR40, n = 18) for the distal. Canal preparation was divided into thirds and the torque, maximum torque and time, were recorded. RESULTS: The RBR25 instruments exhibited higher maximum torque in the apical third in contrast to the WOGP instruments (p < 0.05). The intragroup analysis found a significant difference in maximum torque between the cervical and apical thirds, and the middle and apical thirds (p < 0.05) for both instruments (RBR25 and WOGP). The WOGP group had the shortest preparation time (p < 0.05). There were no significant differences between the WOGL and RBR40 for any of the parameters evaluated (p > 0.05). The RBR25 had the highest torque when compared to the WOGP. Both instruments exhibited higher torque in the apical third and there were no significant differences between the instruments in the distal canal. BioMed Central 2019-01-21 /pmc/articles/PMC6341548/ /pubmed/30665455 http://dx.doi.org/10.1186/s13104-019-4080-z Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Note
Baratto-Filho, Flares
de Freitas, Jéssica Vavassori
Gabardo, Marilisa Carneiro Leão
Tomazinho, Flávia Sens Fagundes
Mazzi-Chaves, Jardel Francisco
de Sousa-Neto, Manoel Damião
Analysis of reciprocating system real-time torque variation during root canal preparation
title Analysis of reciprocating system real-time torque variation during root canal preparation
title_full Analysis of reciprocating system real-time torque variation during root canal preparation
title_fullStr Analysis of reciprocating system real-time torque variation during root canal preparation
title_full_unstemmed Analysis of reciprocating system real-time torque variation during root canal preparation
title_short Analysis of reciprocating system real-time torque variation during root canal preparation
title_sort analysis of reciprocating system real-time torque variation during root canal preparation
topic Research Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6341548/
https://www.ncbi.nlm.nih.gov/pubmed/30665455
http://dx.doi.org/10.1186/s13104-019-4080-z
work_keys_str_mv AT barattofilhoflares analysisofreciprocatingsystemrealtimetorquevariationduringrootcanalpreparation
AT defreitasjessicavavassori analysisofreciprocatingsystemrealtimetorquevariationduringrootcanalpreparation
AT gabardomarilisacarneiroleao analysisofreciprocatingsystemrealtimetorquevariationduringrootcanalpreparation
AT tomazinhoflaviasensfagundes analysisofreciprocatingsystemrealtimetorquevariationduringrootcanalpreparation
AT mazzichavesjardelfrancisco analysisofreciprocatingsystemrealtimetorquevariationduringrootcanalpreparation
AT desousanetomanoeldamiao analysisofreciprocatingsystemrealtimetorquevariationduringrootcanalpreparation