Cargando…

CT Image Conversion among Different Reconstruction Kernels without a Sinogram by Using a Convolutional Neural Network

OBJECTIVE: The aim of our study was to develop and validate a convolutional neural network (CNN) architecture to convert CT images reconstructed with one kernel to images with different reconstruction kernels without using a sinogram. MATERIALS AND METHODS: This retrospective study was approved by t...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sang Min, Lee, June-Goo, Lee, Gaeun, Choe, Jooae, Do, Kyung-Hyun, Kim, Namkug, Seo, Joon Beom
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6342751/
https://www.ncbi.nlm.nih.gov/pubmed/30672169
http://dx.doi.org/10.3348/kjr.2018.0249
_version_ 1783389157115035648
author Lee, Sang Min
Lee, June-Goo
Lee, Gaeun
Choe, Jooae
Do, Kyung-Hyun
Kim, Namkug
Seo, Joon Beom
author_facet Lee, Sang Min
Lee, June-Goo
Lee, Gaeun
Choe, Jooae
Do, Kyung-Hyun
Kim, Namkug
Seo, Joon Beom
author_sort Lee, Sang Min
collection PubMed
description OBJECTIVE: The aim of our study was to develop and validate a convolutional neural network (CNN) architecture to convert CT images reconstructed with one kernel to images with different reconstruction kernels without using a sinogram. MATERIALS AND METHODS: This retrospective study was approved by the Institutional Review Board. Ten chest CT scans were performed and reconstructed with the B10f, B30f, B50f, and B70f kernels. The dataset was divided into six, two, and two examinations for training, validation, and testing, respectively. We constructed a CNN architecture consisting of six convolutional layers, each with a 3 × 3 kernel with 64 filter banks. Quantitative performance was evaluated using root mean square error (RMSE) values. To validate clinical use, image conversion was conducted on 30 additional chest CT scans reconstructed with the B30f and B50f kernels. The influence of image conversion on emphysema quantification was assessed with Bland–Altman plots. RESULTS: Our scheme rapidly generated conversion results at the rate of 0.065 s/slice. Substantial reduction in RMSE was observed in the converted images in comparison with the original images with different kernels (mean reduction, 65.7%; range, 29.5–82.2%). The mean emphysema indices for B30f, B50f, converted B30f, and converted B50f were 5.4 ± 7.2%, 15.3 ± 7.2%, 5.9 ± 7.3%, and 16.8 ± 7.5%, respectively. The 95% limits of agreement between B30f and other kernels (B50f and converted B30f) ranged from −14.1% to −2.6% (mean, −8.3%) and −2.3% to 0.7% (mean, −0.8%), respectively. CONCLUSION: CNN-based CT kernel conversion shows adequate performance with high accuracy and speed, indicating its potential clinical use.
format Online
Article
Text
id pubmed-6342751
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-63427512019-02-01 CT Image Conversion among Different Reconstruction Kernels without a Sinogram by Using a Convolutional Neural Network Lee, Sang Min Lee, June-Goo Lee, Gaeun Choe, Jooae Do, Kyung-Hyun Kim, Namkug Seo, Joon Beom Korean J Radiol Thoracic Imaging OBJECTIVE: The aim of our study was to develop and validate a convolutional neural network (CNN) architecture to convert CT images reconstructed with one kernel to images with different reconstruction kernels without using a sinogram. MATERIALS AND METHODS: This retrospective study was approved by the Institutional Review Board. Ten chest CT scans were performed and reconstructed with the B10f, B30f, B50f, and B70f kernels. The dataset was divided into six, two, and two examinations for training, validation, and testing, respectively. We constructed a CNN architecture consisting of six convolutional layers, each with a 3 × 3 kernel with 64 filter banks. Quantitative performance was evaluated using root mean square error (RMSE) values. To validate clinical use, image conversion was conducted on 30 additional chest CT scans reconstructed with the B30f and B50f kernels. The influence of image conversion on emphysema quantification was assessed with Bland–Altman plots. RESULTS: Our scheme rapidly generated conversion results at the rate of 0.065 s/slice. Substantial reduction in RMSE was observed in the converted images in comparison with the original images with different kernels (mean reduction, 65.7%; range, 29.5–82.2%). The mean emphysema indices for B30f, B50f, converted B30f, and converted B50f were 5.4 ± 7.2%, 15.3 ± 7.2%, 5.9 ± 7.3%, and 16.8 ± 7.5%, respectively. The 95% limits of agreement between B30f and other kernels (B50f and converted B30f) ranged from −14.1% to −2.6% (mean, −8.3%) and −2.3% to 0.7% (mean, −0.8%), respectively. CONCLUSION: CNN-based CT kernel conversion shows adequate performance with high accuracy and speed, indicating its potential clinical use. The Korean Society of Radiology 2019-02 2018-12-28 /pmc/articles/PMC6342751/ /pubmed/30672169 http://dx.doi.org/10.3348/kjr.2018.0249 Text en Copyright © 2019 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Thoracic Imaging
Lee, Sang Min
Lee, June-Goo
Lee, Gaeun
Choe, Jooae
Do, Kyung-Hyun
Kim, Namkug
Seo, Joon Beom
CT Image Conversion among Different Reconstruction Kernels without a Sinogram by Using a Convolutional Neural Network
title CT Image Conversion among Different Reconstruction Kernels without a Sinogram by Using a Convolutional Neural Network
title_full CT Image Conversion among Different Reconstruction Kernels without a Sinogram by Using a Convolutional Neural Network
title_fullStr CT Image Conversion among Different Reconstruction Kernels without a Sinogram by Using a Convolutional Neural Network
title_full_unstemmed CT Image Conversion among Different Reconstruction Kernels without a Sinogram by Using a Convolutional Neural Network
title_short CT Image Conversion among Different Reconstruction Kernels without a Sinogram by Using a Convolutional Neural Network
title_sort ct image conversion among different reconstruction kernels without a sinogram by using a convolutional neural network
topic Thoracic Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6342751/
https://www.ncbi.nlm.nih.gov/pubmed/30672169
http://dx.doi.org/10.3348/kjr.2018.0249
work_keys_str_mv AT leesangmin ctimageconversionamongdifferentreconstructionkernelswithoutasinogrambyusingaconvolutionalneuralnetwork
AT leejunegoo ctimageconversionamongdifferentreconstructionkernelswithoutasinogrambyusingaconvolutionalneuralnetwork
AT leegaeun ctimageconversionamongdifferentreconstructionkernelswithoutasinogrambyusingaconvolutionalneuralnetwork
AT choejooae ctimageconversionamongdifferentreconstructionkernelswithoutasinogrambyusingaconvolutionalneuralnetwork
AT dokyunghyun ctimageconversionamongdifferentreconstructionkernelswithoutasinogrambyusingaconvolutionalneuralnetwork
AT kimnamkug ctimageconversionamongdifferentreconstructionkernelswithoutasinogrambyusingaconvolutionalneuralnetwork
AT seojoonbeom ctimageconversionamongdifferentreconstructionkernelswithoutasinogrambyusingaconvolutionalneuralnetwork