OBJECTIVE: To compare the image quality of three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) with sparse undersampling and iterative reconstruction (sparse TOF) with that of conventional TOF MRA. MATERIALS AND METHODS: This study included 56 patients who had undergone spars...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Hehan, Hu, Na, Yuan, Yuan, Xia, Chunchao, Liu, Xiumin, Zuo, Panli, Stalder, Aurelien F., Schmidt, Michaela, Zhou, Xiaoyue, Song, Bin, Sun, Jiayu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6342758/
https://www.ncbi.nlm.nih.gov/pubmed/30672166
http://dx.doi.org/10.3348/kjr.2017.0634
_version_ 1783389158753959936
author Tang, Hehan
Hu, Na
Yuan, Yuan
Xia, Chunchao
Liu, Xiumin
Zuo, Panli
Stalder, Aurelien F.
Schmidt, Michaela
Zhou, Xiaoyue
Song, Bin
Sun, Jiayu
author_facet Tang, Hehan
Hu, Na
Yuan, Yuan
Xia, Chunchao
Liu, Xiumin
Zuo, Panli
Stalder, Aurelien F.
Schmidt, Michaela
Zhou, Xiaoyue
Song, Bin
Sun, Jiayu
author_sort Tang, Hehan
collection PubMed
description OBJECTIVE: To compare the image quality of three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) with sparse undersampling and iterative reconstruction (sparse TOF) with that of conventional TOF MRA. MATERIALS AND METHODS: This study included 56 patients who had undergone sparse TOF MRA for intracranial artery evaluation on a 3T MR scanner. Conventional TOF MRA scans were also acquired from 29 patients with matched acquisition times and another 27 patients with matched scanning parameters. The image quality was scored using a five-point scale based on the delineation of arterial vessel segments, artifacts, overall vessel visualization, and overall image quality by two radiologists independently, and the data were analyzed using the non-parametric Wilcoxon signed-rank test. Contrast ratios (CRs) of vessels were compared using the paired t test. Interobserver agreement was calculated using the kappa test. RESULTS: Compared with conventional TOF at the same spatial resolution, sparse TOF with an acceleration factor of 3.5 could reduce acquisition time by 40% and showed comparable image quality. In addition, when compared with conventional TOF with the same acquisition time, sparse TOF with an acceleration factor of 5 could also achieve higher spatial resolution, better delineation of vessel segments, fewer artifacts, higher image quality, and a higher CR (p < 0.05). Good-to-excellent interobserver agreement (κ: 0.65–1.00) was obtained between the two radiologists. CONCLUSION: Compared with conventional TOF, sparse TOF can achieve equivalent image quality in a reduced duration. Furthermore, using the same acquisition time, sparse TOF could improve the delineation of vessels and decrease image artifacts.
format Online
Article
Text
id pubmed-6342758
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-63427582019-02-01 Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries Tang, Hehan Hu, Na Yuan, Yuan Xia, Chunchao Liu, Xiumin Zuo, Panli Stalder, Aurelien F. Schmidt, Michaela Zhou, Xiaoyue Song, Bin Sun, Jiayu Korean J Radiol Neuroimaging and Head & Neck OBJECTIVE: To compare the image quality of three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) with sparse undersampling and iterative reconstruction (sparse TOF) with that of conventional TOF MRA. MATERIALS AND METHODS: This study included 56 patients who had undergone sparse TOF MRA for intracranial artery evaluation on a 3T MR scanner. Conventional TOF MRA scans were also acquired from 29 patients with matched acquisition times and another 27 patients with matched scanning parameters. The image quality was scored using a five-point scale based on the delineation of arterial vessel segments, artifacts, overall vessel visualization, and overall image quality by two radiologists independently, and the data were analyzed using the non-parametric Wilcoxon signed-rank test. Contrast ratios (CRs) of vessels were compared using the paired t test. Interobserver agreement was calculated using the kappa test. RESULTS: Compared with conventional TOF at the same spatial resolution, sparse TOF with an acceleration factor of 3.5 could reduce acquisition time by 40% and showed comparable image quality. In addition, when compared with conventional TOF with the same acquisition time, sparse TOF with an acceleration factor of 5 could also achieve higher spatial resolution, better delineation of vessel segments, fewer artifacts, higher image quality, and a higher CR (p < 0.05). Good-to-excellent interobserver agreement (κ: 0.65–1.00) was obtained between the two radiologists. CONCLUSION: Compared with conventional TOF, sparse TOF can achieve equivalent image quality in a reduced duration. Furthermore, using the same acquisition time, sparse TOF could improve the delineation of vessels and decrease image artifacts. The Korean Society of Radiology 2019-02 2018-12-28 /pmc/articles/PMC6342758/ /pubmed/30672166 http://dx.doi.org/10.3348/kjr.2017.0634 Text en Copyright © 2019 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Neuroimaging and Head & Neck
Tang, Hehan
Hu, Na
Yuan, Yuan
Xia, Chunchao
Liu, Xiumin
Zuo, Panli
Stalder, Aurelien F.
Schmidt, Michaela
Zhou, Xiaoyue
Song, Bin
Sun, Jiayu
Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries
title Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries
title_full Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries
title_fullStr Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries
title_full_unstemmed Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries
title_short Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries
title_sort accelerated time-of-flight magnetic resonance angiography with sparse undersampling and iterative reconstruction for the evaluation of intracranial arteries
topic Neuroimaging and Head & Neck
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6342758/
https://www.ncbi.nlm.nih.gov/pubmed/30672166
http://dx.doi.org/10.3348/kjr.2017.0634
work_keys_str_mv AT tanghehan acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT huna acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT yuanyuan acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT xiachunchao acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT liuxiumin acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT zuopanli acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT stalderaurelienf acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT schmidtmichaela acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT zhouxiaoyue acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT songbin acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries
AT sunjiayu acceleratedtimeofflightmagneticresonanceangiographywithsparseundersamplinganditerativereconstructionfortheevaluationofintracranialarteries