Cargando…
Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in Sheffield
Traditional real-time air quality monitoring instruments are expensive to install and maintain; therefore, such existing air quality monitoring networks are sparsely deployed and lack the measurement density to develop high-resolution spatiotemporal air pollutant maps. More recently, low-cost sensor...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343017/ https://www.ncbi.nlm.nih.gov/pubmed/30671683 http://dx.doi.org/10.1007/s10661-019-7231-8 |
_version_ | 1783389202710265856 |
---|---|
author | Munir, Said Mayfield, Martin Coca, Daniel Jubb, Stephen A. Osammor, Ogo |
author_facet | Munir, Said Mayfield, Martin Coca, Daniel Jubb, Stephen A. Osammor, Ogo |
author_sort | Munir, Said |
collection | PubMed |
description | Traditional real-time air quality monitoring instruments are expensive to install and maintain; therefore, such existing air quality monitoring networks are sparsely deployed and lack the measurement density to develop high-resolution spatiotemporal air pollutant maps. More recently, low-cost sensors have been used to collect high-resolution spatial and temporal air pollution data in real-time. In this paper, for the first time, Envirowatch E-MOTEs are employed for air quality monitoring as a case study in Sheffield. Ten E-MOTEs were deployed for a year (October 2016 to September 2017) monitoring several air pollutants (NO, NO(2), CO) and meteorological parameters. Their performance was compared to each other and to a reference instrument installed nearby. E-MOTEs were able to successfully capture the temporal variability such as diurnal, weekly and annual cycles in air pollutant concentrations and demonstrated significant similarity with reference instruments. NO(2) concentrations showed very strong positive correlation between various sensors. Mostly, correlation coefficients (r values) were greater than 0.92. CO from different sensors also had r values mostly greater than 0.92; however, NO showed r value less than 0.5. Furthermore, several multiple linear regression models (MLRM) and generalised additive models (GAM) were developed to calibrate the E-MOTE data and reproduce NO and NO(2) concentrations measured by the reference instruments. GAMs demonstrated significantly better performance than linear models by capturing the non-linear association between the response and explanatory variables. The best GAM developed for reproducing NO(2) concentrations returned values of 0.95, 3.91, 0.81, 0.005 and 0.61 for factor of two (FAC2), root mean square error (RMSE), coefficient of determination (R(2)), normalised mean biased (NMB) and coefficient of efficiency (COE), respectively. The low-cost sensors offer a more affordable alternative for providing real-time high-resolution spatiotemporal air quality and meteorological parameter data with acceptable performance. |
format | Online Article Text |
id | pubmed-6343017 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-63430172019-02-08 Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in Sheffield Munir, Said Mayfield, Martin Coca, Daniel Jubb, Stephen A. Osammor, Ogo Environ Monit Assess Article Traditional real-time air quality monitoring instruments are expensive to install and maintain; therefore, such existing air quality monitoring networks are sparsely deployed and lack the measurement density to develop high-resolution spatiotemporal air pollutant maps. More recently, low-cost sensors have been used to collect high-resolution spatial and temporal air pollution data in real-time. In this paper, for the first time, Envirowatch E-MOTEs are employed for air quality monitoring as a case study in Sheffield. Ten E-MOTEs were deployed for a year (October 2016 to September 2017) monitoring several air pollutants (NO, NO(2), CO) and meteorological parameters. Their performance was compared to each other and to a reference instrument installed nearby. E-MOTEs were able to successfully capture the temporal variability such as diurnal, weekly and annual cycles in air pollutant concentrations and demonstrated significant similarity with reference instruments. NO(2) concentrations showed very strong positive correlation between various sensors. Mostly, correlation coefficients (r values) were greater than 0.92. CO from different sensors also had r values mostly greater than 0.92; however, NO showed r value less than 0.5. Furthermore, several multiple linear regression models (MLRM) and generalised additive models (GAM) were developed to calibrate the E-MOTE data and reproduce NO and NO(2) concentrations measured by the reference instruments. GAMs demonstrated significantly better performance than linear models by capturing the non-linear association between the response and explanatory variables. The best GAM developed for reproducing NO(2) concentrations returned values of 0.95, 3.91, 0.81, 0.005 and 0.61 for factor of two (FAC2), root mean square error (RMSE), coefficient of determination (R(2)), normalised mean biased (NMB) and coefficient of efficiency (COE), respectively. The low-cost sensors offer a more affordable alternative for providing real-time high-resolution spatiotemporal air quality and meteorological parameter data with acceptable performance. Springer International Publishing 2019-01-22 2019 /pmc/articles/PMC6343017/ /pubmed/30671683 http://dx.doi.org/10.1007/s10661-019-7231-8 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Article Munir, Said Mayfield, Martin Coca, Daniel Jubb, Stephen A. Osammor, Ogo Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in Sheffield |
title | Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in Sheffield |
title_full | Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in Sheffield |
title_fullStr | Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in Sheffield |
title_full_unstemmed | Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in Sheffield |
title_short | Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in Sheffield |
title_sort | analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in sheffield |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343017/ https://www.ncbi.nlm.nih.gov/pubmed/30671683 http://dx.doi.org/10.1007/s10661-019-7231-8 |
work_keys_str_mv | AT munirsaid analysingtheperformanceoflowcostairqualitysensorstheirdriversrelativebenefitsandcalibrationincitiesacasestudyinsheffield AT mayfieldmartin analysingtheperformanceoflowcostairqualitysensorstheirdriversrelativebenefitsandcalibrationincitiesacasestudyinsheffield AT cocadaniel analysingtheperformanceoflowcostairqualitysensorstheirdriversrelativebenefitsandcalibrationincitiesacasestudyinsheffield AT jubbstephena analysingtheperformanceoflowcostairqualitysensorstheirdriversrelativebenefitsandcalibrationincitiesacasestudyinsheffield AT osammorogo analysingtheperformanceoflowcostairqualitysensorstheirdriversrelativebenefitsandcalibrationincitiesacasestudyinsheffield |