Cargando…

Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography

BACKGROUND: In this study, we explored how various preprocessing approaches can be employed to enhance the capability of dental CBCT to accurately estimate trabecular bone microarchitectural parameters. METHODS: In total, 30 bovine vertebrae cancellous bone specimens were used for in study. Voxel re...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Rong-Ting, Tu, Ming-Gene, Huang, Heng-Li, Tsai, Ming-Tzu, Wu, Jay, Hsu, Jui-Ting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343305/
https://www.ncbi.nlm.nih.gov/pubmed/30674282
http://dx.doi.org/10.1186/s12880-019-0313-9
_version_ 1783389259269406720
author He, Rong-Ting
Tu, Ming-Gene
Huang, Heng-Li
Tsai, Ming-Tzu
Wu, Jay
Hsu, Jui-Ting
author_facet He, Rong-Ting
Tu, Ming-Gene
Huang, Heng-Li
Tsai, Ming-Tzu
Wu, Jay
Hsu, Jui-Ting
author_sort He, Rong-Ting
collection PubMed
description BACKGROUND: In this study, we explored how various preprocessing approaches can be employed to enhance the capability of dental CBCT to accurately estimate trabecular bone microarchitectural parameters. METHODS: In total, 30 bovine vertebrae cancellous bone specimens were used for in study. Voxel resolution 18-μm micro-computed tomography (micro-CT) and 100-μm dental CBCT were used to scan each specimen. Micro-CT images were used to calculate trabecular bone microarchitectural parameters; the results were set as the gold standard. Subsequently, before the dental CBCT images were converted into binary images to calculate trabecular bone microarchitectural parameters, three preprocessing approaches were used to process the dental CBCT images. For Group 1, no preprocessing approach was applied. For Group 2, images were sharpened and despeckable noises were removed. For Group 3, the function of local thresholding was added to Group 2 to form Group 3. For Group 4, the air pixels was removed from Group 3 to form Group 4. Subsequently, all images were imported into a software package to estimate trabecular bone microarchitectural parameters (bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular number (TbN), and trabecular separation (TbSp)). Finally, a paired t-test and a Pearson correlation test were performed to compare the capability of micro-CT with the capability of dental CBCT for estimating trabecular bone microarchitectural parameters. RESULTS: Regardless of whether dental CBCT images underwent image preprocessing (Groups 1 to 4), the four trabecular bone microarchitectural parameters measured using dental CBCT images were significantly different from those measured using micro-CT images. However, after three image preprocessing approaches were applied to the dental CBCT images (Group 4), the BV/TV obtained using dental CBCT was highly positively correlated with that obtained using micro-CT (r = 0.87, p < 0.001); the correlation coefficient was greater than that of Group 1 (r = −0.15, p = 0.412), Group 2 (r = 0.16, p = 0.386), and Group 3 (r = 0.47, p = 0.006). After dental CBCT images underwent image preprocessing, the efficacy of using dental CBCT for estimating TbN and TbSp was enhanced. CONCLUSIONS: Image preprocessing approaches can be used to enhance the efficacy of using dental CBCT for predicting trabecular bone microarchitectural parameters.
format Online
Article
Text
id pubmed-6343305
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63433052019-01-24 Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography He, Rong-Ting Tu, Ming-Gene Huang, Heng-Li Tsai, Ming-Tzu Wu, Jay Hsu, Jui-Ting BMC Med Imaging Research Article BACKGROUND: In this study, we explored how various preprocessing approaches can be employed to enhance the capability of dental CBCT to accurately estimate trabecular bone microarchitectural parameters. METHODS: In total, 30 bovine vertebrae cancellous bone specimens were used for in study. Voxel resolution 18-μm micro-computed tomography (micro-CT) and 100-μm dental CBCT were used to scan each specimen. Micro-CT images were used to calculate trabecular bone microarchitectural parameters; the results were set as the gold standard. Subsequently, before the dental CBCT images were converted into binary images to calculate trabecular bone microarchitectural parameters, three preprocessing approaches were used to process the dental CBCT images. For Group 1, no preprocessing approach was applied. For Group 2, images were sharpened and despeckable noises were removed. For Group 3, the function of local thresholding was added to Group 2 to form Group 3. For Group 4, the air pixels was removed from Group 3 to form Group 4. Subsequently, all images were imported into a software package to estimate trabecular bone microarchitectural parameters (bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular number (TbN), and trabecular separation (TbSp)). Finally, a paired t-test and a Pearson correlation test were performed to compare the capability of micro-CT with the capability of dental CBCT for estimating trabecular bone microarchitectural parameters. RESULTS: Regardless of whether dental CBCT images underwent image preprocessing (Groups 1 to 4), the four trabecular bone microarchitectural parameters measured using dental CBCT images were significantly different from those measured using micro-CT images. However, after three image preprocessing approaches were applied to the dental CBCT images (Group 4), the BV/TV obtained using dental CBCT was highly positively correlated with that obtained using micro-CT (r = 0.87, p < 0.001); the correlation coefficient was greater than that of Group 1 (r = −0.15, p = 0.412), Group 2 (r = 0.16, p = 0.386), and Group 3 (r = 0.47, p = 0.006). After dental CBCT images underwent image preprocessing, the efficacy of using dental CBCT for estimating TbN and TbSp was enhanced. CONCLUSIONS: Image preprocessing approaches can be used to enhance the efficacy of using dental CBCT for predicting trabecular bone microarchitectural parameters. BioMed Central 2019-01-23 /pmc/articles/PMC6343305/ /pubmed/30674282 http://dx.doi.org/10.1186/s12880-019-0313-9 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
He, Rong-Ting
Tu, Ming-Gene
Huang, Heng-Li
Tsai, Ming-Tzu
Wu, Jay
Hsu, Jui-Ting
Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
title Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
title_full Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
title_fullStr Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
title_full_unstemmed Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
title_short Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
title_sort improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343305/
https://www.ncbi.nlm.nih.gov/pubmed/30674282
http://dx.doi.org/10.1186/s12880-019-0313-9
work_keys_str_mv AT herongting improvingthepredictionofthetrabecularbonemicroarchitecturalparametersusingdentalconebeamcomputedtomography
AT tuminggene improvingthepredictionofthetrabecularbonemicroarchitecturalparametersusingdentalconebeamcomputedtomography
AT huanghengli improvingthepredictionofthetrabecularbonemicroarchitecturalparametersusingdentalconebeamcomputedtomography
AT tsaimingtzu improvingthepredictionofthetrabecularbonemicroarchitecturalparametersusingdentalconebeamcomputedtomography
AT wujay improvingthepredictionofthetrabecularbonemicroarchitecturalparametersusingdentalconebeamcomputedtomography
AT hsujuiting improvingthepredictionofthetrabecularbonemicroarchitecturalparametersusingdentalconebeamcomputedtomography