Cargando…

Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools

BACKGROUND: Poor indoor air quality is a great problem in schools due to a high number of students per classroom, insufficient outside air supply, poor construction and maintenance of school buildings. Bacteria in the indoor air environment pose a serious health problem. Determination of bacterial l...

Descripción completa

Detalles Bibliográficos
Autores principales: Andualem, Zewudu, Gizaw, Zemichael, Bogale, Laekemariam, Dagne, Henok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343310/
https://www.ncbi.nlm.nih.gov/pubmed/30680192
http://dx.doi.org/10.1186/s40248-018-0167-y
_version_ 1783389260480512000
author Andualem, Zewudu
Gizaw, Zemichael
Bogale, Laekemariam
Dagne, Henok
author_facet Andualem, Zewudu
Gizaw, Zemichael
Bogale, Laekemariam
Dagne, Henok
author_sort Andualem, Zewudu
collection PubMed
description BACKGROUND: Poor indoor air quality is a great problem in schools due to a high number of students per classroom, insufficient outside air supply, poor construction and maintenance of school buildings. Bacteria in the indoor air environment pose a serious health problem. Determination of bacterial load in the indoor environment is necessary to estimate the health hazard and to create standards for indoor air quality control. This is especially important in such densely populated facilities like schools. METHODS: Institutional based cross-sectional study was conducted among 51 randomly selected classrooms of eight public primary schools from March 29–April 26, 2018. To determine the bacterial load passive air sampling settle plate method was used by exposing a Petri dish of blood agar media for an hour. The Pearson correlation matrix was employed to assess the correlation between bacterial load and physical parameters. RESULTS: The grand total mean bacterial load was 2826.35 CFU/m(3) in the morning and 4514.63 CFU/m(3) in the afternoon. The lowest and highest mean bacterial load was recorded at school 3 (450.67 CFU/m(3)) and school 5 (7740.57 CFU/m(3)) in the morning and afternoon, respectively. In the morning relative humidity (r = − 0.7034), PM2.5 (r = 0.5723) and PM10 (r = 0.6856); in the afternoon temperature (r = 0.3838), relative humidity (r = − 0.4014) were correlated with indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus species and Bacillus species were among isolated bacteria. CONCLUSIONS: High bacterial load was found in public primary schools in the Gondar city as compared to different indoor air biological standards. Temperature, relative humidity and particulate matter concentration (PM2.5 and PM10) were associated with the indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus species and Bacillus species were among isolated bacterial species. Attention should be given to control those physical factors which favour the growth and multiplication of bacteria in the indoor environment of classrooms to safeguard the health of students and teachers in school.
format Online
Article
Text
id pubmed-6343310
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63433102019-01-24 Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools Andualem, Zewudu Gizaw, Zemichael Bogale, Laekemariam Dagne, Henok Multidiscip Respir Med Original Research Article BACKGROUND: Poor indoor air quality is a great problem in schools due to a high number of students per classroom, insufficient outside air supply, poor construction and maintenance of school buildings. Bacteria in the indoor air environment pose a serious health problem. Determination of bacterial load in the indoor environment is necessary to estimate the health hazard and to create standards for indoor air quality control. This is especially important in such densely populated facilities like schools. METHODS: Institutional based cross-sectional study was conducted among 51 randomly selected classrooms of eight public primary schools from March 29–April 26, 2018. To determine the bacterial load passive air sampling settle plate method was used by exposing a Petri dish of blood agar media for an hour. The Pearson correlation matrix was employed to assess the correlation between bacterial load and physical parameters. RESULTS: The grand total mean bacterial load was 2826.35 CFU/m(3) in the morning and 4514.63 CFU/m(3) in the afternoon. The lowest and highest mean bacterial load was recorded at school 3 (450.67 CFU/m(3)) and school 5 (7740.57 CFU/m(3)) in the morning and afternoon, respectively. In the morning relative humidity (r = − 0.7034), PM2.5 (r = 0.5723) and PM10 (r = 0.6856); in the afternoon temperature (r = 0.3838), relative humidity (r = − 0.4014) were correlated with indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus species and Bacillus species were among isolated bacteria. CONCLUSIONS: High bacterial load was found in public primary schools in the Gondar city as compared to different indoor air biological standards. Temperature, relative humidity and particulate matter concentration (PM2.5 and PM10) were associated with the indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus species and Bacillus species were among isolated bacterial species. Attention should be given to control those physical factors which favour the growth and multiplication of bacteria in the indoor environment of classrooms to safeguard the health of students and teachers in school. BioMed Central 2019-01-22 /pmc/articles/PMC6343310/ /pubmed/30680192 http://dx.doi.org/10.1186/s40248-018-0167-y Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Research Article
Andualem, Zewudu
Gizaw, Zemichael
Bogale, Laekemariam
Dagne, Henok
Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
title Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
title_full Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
title_fullStr Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
title_full_unstemmed Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
title_short Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
title_sort indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343310/
https://www.ncbi.nlm.nih.gov/pubmed/30680192
http://dx.doi.org/10.1186/s40248-018-0167-y
work_keys_str_mv AT andualemzewudu indoorbacterialloadanditscorrelationtophysicalindoorairqualityparametersinpublicprimaryschools
AT gizawzemichael indoorbacterialloadanditscorrelationtophysicalindoorairqualityparametersinpublicprimaryschools
AT bogalelaekemariam indoorbacterialloadanditscorrelationtophysicalindoorairqualityparametersinpublicprimaryschools
AT dagnehenok indoorbacterialloadanditscorrelationtophysicalindoorairqualityparametersinpublicprimaryschools