Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot
BACKGROUND: Application of transannular patch (TAP) during the repair of tetralogy of Fallot (TOF) leads to the development of pulmonary regurgitation (PR). This PR is known to cause right ventricular (RV) volume overload and dysfunction which in turn leads to increase in both morbidity and mortalit...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343384/ https://www.ncbi.nlm.nih.gov/pubmed/30745766 http://dx.doi.org/10.4103/apc.APC_51_18 |
_version_ | 1783389277401382912 |
---|---|
author | Wankhade, Prashant Ramdas Aggarwal, Neeraj Joshi, Reena Khantwal Agarwal, Mridul Joshi, Raja Mehta, Ashwani Kar, Sibashankar |
author_facet | Wankhade, Prashant Ramdas Aggarwal, Neeraj Joshi, Reena Khantwal Agarwal, Mridul Joshi, Raja Mehta, Ashwani Kar, Sibashankar |
author_sort | Wankhade, Prashant Ramdas |
collection | PubMed |
description | BACKGROUND: Application of transannular patch (TAP) during the repair of tetralogy of Fallot (TOF) leads to the development of pulmonary regurgitation (PR). This PR is known to cause right ventricular (RV) volume overload and dysfunction which in turn leads to increase in both morbidity and mortality both in immediate and long-term periods. Here, we sought to analyze the effects of polytetrafluoroethylene (PTFE) pulmonary bicuspid valve on the early outcome of patients with TOF repair where TAP is needed. SUBJECTS AND METHODS: This is a retroprospective, observational study where PTFE bicuspid pulmonary valve was incorporated in all consecutive patients undergoing repair of TOF involving the application of TAP. Postoperative inhospital course was assessed, and patients were followed till 6 months for the status of PR and peak RV outflow tract (RVOT) gradient. RESULTS: 38 patients were enrolled in the study. The mean age of participants was 53.66 ± 78.67 months. Extubation in operating room was done in 31 (81.58%) patients. Duration of ventilator support was 10.48 ± 24.22 h, and duration of hospital stay was 7.95 ± 3.08 days. These data were compared with three recent studies where only TAP was applied. Extubation in operating room, mechanical ventilation time, and hospital stay were significantly improved in the present study. Out of 37 live patients, four (10.81%) patients had no PR, 28 (75%) had mild, 1 (2.7) had moderate, and 4 (10.81%) had severe PR. Average RVOT peak gradient was 18.8 ± 8.1 mmHg. CONCLUSION: Incorporation of PTFE bicuspid pulmonary valve during the repair of TOF appears to facilitate early extubation and thus reduces ventilator-associated comorbidities. Study needs further long-term follow-up to look for behavior of PTFE bicuspid valve. |
format | Online Article Text |
id | pubmed-6343384 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-63433842019-02-11 Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot Wankhade, Prashant Ramdas Aggarwal, Neeraj Joshi, Reena Khantwal Agarwal, Mridul Joshi, Raja Mehta, Ashwani Kar, Sibashankar Ann Pediatr Cardiol Original Article BACKGROUND: Application of transannular patch (TAP) during the repair of tetralogy of Fallot (TOF) leads to the development of pulmonary regurgitation (PR). This PR is known to cause right ventricular (RV) volume overload and dysfunction which in turn leads to increase in both morbidity and mortality both in immediate and long-term periods. Here, we sought to analyze the effects of polytetrafluoroethylene (PTFE) pulmonary bicuspid valve on the early outcome of patients with TOF repair where TAP is needed. SUBJECTS AND METHODS: This is a retroprospective, observational study where PTFE bicuspid pulmonary valve was incorporated in all consecutive patients undergoing repair of TOF involving the application of TAP. Postoperative inhospital course was assessed, and patients were followed till 6 months for the status of PR and peak RV outflow tract (RVOT) gradient. RESULTS: 38 patients were enrolled in the study. The mean age of participants was 53.66 ± 78.67 months. Extubation in operating room was done in 31 (81.58%) patients. Duration of ventilator support was 10.48 ± 24.22 h, and duration of hospital stay was 7.95 ± 3.08 days. These data were compared with three recent studies where only TAP was applied. Extubation in operating room, mechanical ventilation time, and hospital stay were significantly improved in the present study. Out of 37 live patients, four (10.81%) patients had no PR, 28 (75%) had mild, 1 (2.7) had moderate, and 4 (10.81%) had severe PR. Average RVOT peak gradient was 18.8 ± 8.1 mmHg. CONCLUSION: Incorporation of PTFE bicuspid pulmonary valve during the repair of TOF appears to facilitate early extubation and thus reduces ventilator-associated comorbidities. Study needs further long-term follow-up to look for behavior of PTFE bicuspid valve. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6343384/ /pubmed/30745766 http://dx.doi.org/10.4103/apc.APC_51_18 Text en Copyright: © 2019 Annals of Pediatric Cardiology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Wankhade, Prashant Ramdas Aggarwal, Neeraj Joshi, Reena Khantwal Agarwal, Mridul Joshi, Raja Mehta, Ashwani Kar, Sibashankar Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot |
title | Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot |
title_full | Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot |
title_fullStr | Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot |
title_full_unstemmed | Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot |
title_short | Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot |
title_sort | short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of fallot |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343384/ https://www.ncbi.nlm.nih.gov/pubmed/30745766 http://dx.doi.org/10.4103/apc.APC_51_18 |
work_keys_str_mv | AT wankhadeprashantramdas shorttermclinicalandechocardiographicoutcomesafteruseofpolytetrafluoroethylenebicuspidpulmonaryvalveduringtherepairoftetralogyoffallot AT aggarwalneeraj shorttermclinicalandechocardiographicoutcomesafteruseofpolytetrafluoroethylenebicuspidpulmonaryvalveduringtherepairoftetralogyoffallot AT joshireenakhantwal shorttermclinicalandechocardiographicoutcomesafteruseofpolytetrafluoroethylenebicuspidpulmonaryvalveduringtherepairoftetralogyoffallot AT agarwalmridul shorttermclinicalandechocardiographicoutcomesafteruseofpolytetrafluoroethylenebicuspidpulmonaryvalveduringtherepairoftetralogyoffallot AT joshiraja shorttermclinicalandechocardiographicoutcomesafteruseofpolytetrafluoroethylenebicuspidpulmonaryvalveduringtherepairoftetralogyoffallot AT mehtaashwani shorttermclinicalandechocardiographicoutcomesafteruseofpolytetrafluoroethylenebicuspidpulmonaryvalveduringtherepairoftetralogyoffallot AT karsibashankar shorttermclinicalandechocardiographicoutcomesafteruseofpolytetrafluoroethylenebicuspidpulmonaryvalveduringtherepairoftetralogyoffallot |