Cargando…

Treatment of Periprosthetic Humeral Shaft Fracture after Total Elbow Arthroplasty in an Osteoporotic Patient, using the Ilizarov External Ring Fixator: A Case Report

INTRODUCTION: Periprosthetic humeral shaft fracture after total elbow arthroplasty (TEA) and open reduction and internal fixation at the same side humeral neck fracture in patients with osteoporosis poses a treatment challenge. Herein, we describe our experience with its treatment using the Ilizarov...

Descripción completa

Detalles Bibliográficos
Autores principales: Yanagisawa, Yohei, Hara, Yuki, Nozawa, Daisuke, Yamazaki, Masashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343564/
https://www.ncbi.nlm.nih.gov/pubmed/30687671
http://dx.doi.org/10.13107/jocr.2250-0685.1172
_version_ 1783389307175698432
author Yanagisawa, Yohei
Hara, Yuki
Nozawa, Daisuke
Yamazaki, Masashi
author_facet Yanagisawa, Yohei
Hara, Yuki
Nozawa, Daisuke
Yamazaki, Masashi
author_sort Yanagisawa, Yohei
collection PubMed
description INTRODUCTION: Periprosthetic humeral shaft fracture after total elbow arthroplasty (TEA) and open reduction and internal fixation at the same side humeral neck fracture in patients with osteoporosis poses a treatment challenge. Herein, we describe our experience with its treatment using the Ilizarov external ring fixator. CASE REPORT: A 74-year-old Japanese woman with rheumatoid arthritis and osteoporosis sustained a periprosthetic humeral shaft fracture. The fracture was externally fixated with the Ilizarov external ring fixator, and five wires (Orthofix, Lewisville, Texas) were inserted just beside the components of the TEA (three wires were beside the humeral component and two wires the ulnar component). 4 months postoperatively, the fracture showed bone union and the fixator was removed. There were minor pin tract infections treated with oral antibiotics and transient ulnar nerve palsy with resolution after 6 months of the fixator removal. During the period of wearing the fixator, the left elbow joint was immobilized, and mainly isometric muscle exercises were performed. At 6 months of follow-up after the fixator removal, the patient was pain free, with good functional results (patient-rated elbow evaluation Japanese version 8.6 and quick- disability of the arm, shoulder, and hand Japanese version 20.5), elbow range of motion 10–°, 80° pronation, and 80° supination. The patient returned successfully to her pre-injury occupational activities. CONCLUSION: We believe that the use of the Ilizarov external fixator is a useful option for managing periprosthetic humeral shaft fractures after TEA in patients with osteoporosis.
format Online
Article
Text
id pubmed-6343564
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-63435642019-01-26 Treatment of Periprosthetic Humeral Shaft Fracture after Total Elbow Arthroplasty in an Osteoporotic Patient, using the Ilizarov External Ring Fixator: A Case Report Yanagisawa, Yohei Hara, Yuki Nozawa, Daisuke Yamazaki, Masashi J Orthop Case Rep Case Report INTRODUCTION: Periprosthetic humeral shaft fracture after total elbow arthroplasty (TEA) and open reduction and internal fixation at the same side humeral neck fracture in patients with osteoporosis poses a treatment challenge. Herein, we describe our experience with its treatment using the Ilizarov external ring fixator. CASE REPORT: A 74-year-old Japanese woman with rheumatoid arthritis and osteoporosis sustained a periprosthetic humeral shaft fracture. The fracture was externally fixated with the Ilizarov external ring fixator, and five wires (Orthofix, Lewisville, Texas) were inserted just beside the components of the TEA (three wires were beside the humeral component and two wires the ulnar component). 4 months postoperatively, the fracture showed bone union and the fixator was removed. There were minor pin tract infections treated with oral antibiotics and transient ulnar nerve palsy with resolution after 6 months of the fixator removal. During the period of wearing the fixator, the left elbow joint was immobilized, and mainly isometric muscle exercises were performed. At 6 months of follow-up after the fixator removal, the patient was pain free, with good functional results (patient-rated elbow evaluation Japanese version 8.6 and quick- disability of the arm, shoulder, and hand Japanese version 20.5), elbow range of motion 10–°, 80° pronation, and 80° supination. The patient returned successfully to her pre-injury occupational activities. CONCLUSION: We believe that the use of the Ilizarov external fixator is a useful option for managing periprosthetic humeral shaft fractures after TEA in patients with osteoporosis. Indian Orthopaedic Research Group 2018 /pmc/articles/PMC6343564/ /pubmed/30687671 http://dx.doi.org/10.13107/jocr.2250-0685.1172 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Yanagisawa, Yohei
Hara, Yuki
Nozawa, Daisuke
Yamazaki, Masashi
Treatment of Periprosthetic Humeral Shaft Fracture after Total Elbow Arthroplasty in an Osteoporotic Patient, using the Ilizarov External Ring Fixator: A Case Report
title Treatment of Periprosthetic Humeral Shaft Fracture after Total Elbow Arthroplasty in an Osteoporotic Patient, using the Ilizarov External Ring Fixator: A Case Report
title_full Treatment of Periprosthetic Humeral Shaft Fracture after Total Elbow Arthroplasty in an Osteoporotic Patient, using the Ilizarov External Ring Fixator: A Case Report
title_fullStr Treatment of Periprosthetic Humeral Shaft Fracture after Total Elbow Arthroplasty in an Osteoporotic Patient, using the Ilizarov External Ring Fixator: A Case Report
title_full_unstemmed Treatment of Periprosthetic Humeral Shaft Fracture after Total Elbow Arthroplasty in an Osteoporotic Patient, using the Ilizarov External Ring Fixator: A Case Report
title_short Treatment of Periprosthetic Humeral Shaft Fracture after Total Elbow Arthroplasty in an Osteoporotic Patient, using the Ilizarov External Ring Fixator: A Case Report
title_sort treatment of periprosthetic humeral shaft fracture after total elbow arthroplasty in an osteoporotic patient, using the ilizarov external ring fixator: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343564/
https://www.ncbi.nlm.nih.gov/pubmed/30687671
http://dx.doi.org/10.13107/jocr.2250-0685.1172
work_keys_str_mv AT yanagisawayohei treatmentofperiprosthetichumeralshaftfractureaftertotalelbowarthroplastyinanosteoporoticpatientusingtheilizarovexternalringfixatoracasereport
AT harayuki treatmentofperiprosthetichumeralshaftfractureaftertotalelbowarthroplastyinanosteoporoticpatientusingtheilizarovexternalringfixatoracasereport
AT nozawadaisuke treatmentofperiprosthetichumeralshaftfractureaftertotalelbowarthroplastyinanosteoporoticpatientusingtheilizarovexternalringfixatoracasereport
AT yamazakimasashi treatmentofperiprosthetichumeralshaftfractureaftertotalelbowarthroplastyinanosteoporoticpatientusingtheilizarovexternalringfixatoracasereport