Cargando…

CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics

BACKGROUND: CD4 T-cell counts are still widely used to assess treatment eligibility and follow-up of HIV-infected patients. The World Health Organization (WHO) prequalification of in vitro diagnostics requested a manufacturer independent laboratory evaluation of the analytical performance at the Ins...

Descripción completa

Detalles Bibliográficos
Autores principales: Ceulemans, Ann, Bouzahzah, Chaymae, Prat, Irena, Urassa, Willy, Kestens, Luc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343963/
https://www.ncbi.nlm.nih.gov/pubmed/30673713
http://dx.doi.org/10.1371/journal.pone.0209677
_version_ 1783389357798850560
author Ceulemans, Ann
Bouzahzah, Chaymae
Prat, Irena
Urassa, Willy
Kestens, Luc
author_facet Ceulemans, Ann
Bouzahzah, Chaymae
Prat, Irena
Urassa, Willy
Kestens, Luc
author_sort Ceulemans, Ann
collection PubMed
description BACKGROUND: CD4 T-cell counts are still widely used to assess treatment eligibility and follow-up of HIV-infected patients. The World Health Organization (WHO) prequalification of in vitro diagnostics requested a manufacturer independent laboratory evaluation of the analytical performance at the Institute of Tropical Medicine (ITM) Antwerp, Belgium, of the Muse Auto CD4/CD4% system (Millipore), a new small capillary-flow cytometer dedicated to count absolute CD4-T cells and percentages in venous blood samples from HIV-infected patients. METHODS: Two hundred and fifty (250) patients were recruited from the HIV outpatient clinic at ITM. Accuracy and precision of CD4 T cell counting on fresh EDTA anticoagulated venous blood samples were assessed in the laboratory on a Muse Auto CD4/CD4% system. Extensive precision analyses were performed both on fresh blood and on normal and low stabilized whole blood controls. Accuracy ((bias) was assessed by comparing results from Muse CD4/CD4% to the reference (single-platform FACSCalibur). Clinical misclassification was measured at 500, 350, 200 and 100 cells/μL thresholds. RESULTS: Intra-assay precision was < 5%, and inter-assay was < 9%. CD4 T cell counts measured on Muse Auto CD4/CD4% System and on the reference instrument resulted in regression slopes of 0.97 for absolute counts and 1.03 for CD4 T cell percentages and a correlation coefficient of 0.99 for both. The average absolute bias as compared to the reference was negligible (4 cells/μL or 0.5%). The absolute average bias on CD4 T cell percentages was < 1%. Clinical misclassification at different CD4 T cell thresholds was small resulting in sensitivities and specificities equal or >90% at all thresholds except at 100 cells/μL (sensitivity = 87%). All samples could be analyzed as there was no repetitive rejection errors recorded. CONCLUSIONS: The Muse Auto CD4/CD4% System performed very well on fresh venous blood samples and met all WHO acceptance criteria for analytical performance of CD4 technologies.
format Online
Article
Text
id pubmed-6343963
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-63439632019-02-02 CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics Ceulemans, Ann Bouzahzah, Chaymae Prat, Irena Urassa, Willy Kestens, Luc PLoS One Research Article BACKGROUND: CD4 T-cell counts are still widely used to assess treatment eligibility and follow-up of HIV-infected patients. The World Health Organization (WHO) prequalification of in vitro diagnostics requested a manufacturer independent laboratory evaluation of the analytical performance at the Institute of Tropical Medicine (ITM) Antwerp, Belgium, of the Muse Auto CD4/CD4% system (Millipore), a new small capillary-flow cytometer dedicated to count absolute CD4-T cells and percentages in venous blood samples from HIV-infected patients. METHODS: Two hundred and fifty (250) patients were recruited from the HIV outpatient clinic at ITM. Accuracy and precision of CD4 T cell counting on fresh EDTA anticoagulated venous blood samples were assessed in the laboratory on a Muse Auto CD4/CD4% system. Extensive precision analyses were performed both on fresh blood and on normal and low stabilized whole blood controls. Accuracy ((bias) was assessed by comparing results from Muse CD4/CD4% to the reference (single-platform FACSCalibur). Clinical misclassification was measured at 500, 350, 200 and 100 cells/μL thresholds. RESULTS: Intra-assay precision was < 5%, and inter-assay was < 9%. CD4 T cell counts measured on Muse Auto CD4/CD4% System and on the reference instrument resulted in regression slopes of 0.97 for absolute counts and 1.03 for CD4 T cell percentages and a correlation coefficient of 0.99 for both. The average absolute bias as compared to the reference was negligible (4 cells/μL or 0.5%). The absolute average bias on CD4 T cell percentages was < 1%. Clinical misclassification at different CD4 T cell thresholds was small resulting in sensitivities and specificities equal or >90% at all thresholds except at 100 cells/μL (sensitivity = 87%). All samples could be analyzed as there was no repetitive rejection errors recorded. CONCLUSIONS: The Muse Auto CD4/CD4% System performed very well on fresh venous blood samples and met all WHO acceptance criteria for analytical performance of CD4 technologies. Public Library of Science 2019-01-23 /pmc/articles/PMC6343963/ /pubmed/30673713 http://dx.doi.org/10.1371/journal.pone.0209677 Text en © 2019 Ceulemans et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ceulemans, Ann
Bouzahzah, Chaymae
Prat, Irena
Urassa, Willy
Kestens, Luc
CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics
title CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics
title_full CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics
title_fullStr CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics
title_full_unstemmed CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics
title_short CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics
title_sort cd4-t cell enumeration in human immunodeficiency virus (hiv)-infected patients: a laboratory performance evaluation of muse auto cd4/cd4% system by world health organization prequalification of in vitro diagnostics
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343963/
https://www.ncbi.nlm.nih.gov/pubmed/30673713
http://dx.doi.org/10.1371/journal.pone.0209677
work_keys_str_mv AT ceulemansann cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics
AT bouzahzahchaymae cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics
AT pratirena cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics
AT urassawilly cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics
AT kestensluc cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics