Cargando…
CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics
BACKGROUND: CD4 T-cell counts are still widely used to assess treatment eligibility and follow-up of HIV-infected patients. The World Health Organization (WHO) prequalification of in vitro diagnostics requested a manufacturer independent laboratory evaluation of the analytical performance at the Ins...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343963/ https://www.ncbi.nlm.nih.gov/pubmed/30673713 http://dx.doi.org/10.1371/journal.pone.0209677 |
_version_ | 1783389357798850560 |
---|---|
author | Ceulemans, Ann Bouzahzah, Chaymae Prat, Irena Urassa, Willy Kestens, Luc |
author_facet | Ceulemans, Ann Bouzahzah, Chaymae Prat, Irena Urassa, Willy Kestens, Luc |
author_sort | Ceulemans, Ann |
collection | PubMed |
description | BACKGROUND: CD4 T-cell counts are still widely used to assess treatment eligibility and follow-up of HIV-infected patients. The World Health Organization (WHO) prequalification of in vitro diagnostics requested a manufacturer independent laboratory evaluation of the analytical performance at the Institute of Tropical Medicine (ITM) Antwerp, Belgium, of the Muse Auto CD4/CD4% system (Millipore), a new small capillary-flow cytometer dedicated to count absolute CD4-T cells and percentages in venous blood samples from HIV-infected patients. METHODS: Two hundred and fifty (250) patients were recruited from the HIV outpatient clinic at ITM. Accuracy and precision of CD4 T cell counting on fresh EDTA anticoagulated venous blood samples were assessed in the laboratory on a Muse Auto CD4/CD4% system. Extensive precision analyses were performed both on fresh blood and on normal and low stabilized whole blood controls. Accuracy ((bias) was assessed by comparing results from Muse CD4/CD4% to the reference (single-platform FACSCalibur). Clinical misclassification was measured at 500, 350, 200 and 100 cells/μL thresholds. RESULTS: Intra-assay precision was < 5%, and inter-assay was < 9%. CD4 T cell counts measured on Muse Auto CD4/CD4% System and on the reference instrument resulted in regression slopes of 0.97 for absolute counts and 1.03 for CD4 T cell percentages and a correlation coefficient of 0.99 for both. The average absolute bias as compared to the reference was negligible (4 cells/μL or 0.5%). The absolute average bias on CD4 T cell percentages was < 1%. Clinical misclassification at different CD4 T cell thresholds was small resulting in sensitivities and specificities equal or >90% at all thresholds except at 100 cells/μL (sensitivity = 87%). All samples could be analyzed as there was no repetitive rejection errors recorded. CONCLUSIONS: The Muse Auto CD4/CD4% System performed very well on fresh venous blood samples and met all WHO acceptance criteria for analytical performance of CD4 technologies. |
format | Online Article Text |
id | pubmed-6343963 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-63439632019-02-02 CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics Ceulemans, Ann Bouzahzah, Chaymae Prat, Irena Urassa, Willy Kestens, Luc PLoS One Research Article BACKGROUND: CD4 T-cell counts are still widely used to assess treatment eligibility and follow-up of HIV-infected patients. The World Health Organization (WHO) prequalification of in vitro diagnostics requested a manufacturer independent laboratory evaluation of the analytical performance at the Institute of Tropical Medicine (ITM) Antwerp, Belgium, of the Muse Auto CD4/CD4% system (Millipore), a new small capillary-flow cytometer dedicated to count absolute CD4-T cells and percentages in venous blood samples from HIV-infected patients. METHODS: Two hundred and fifty (250) patients were recruited from the HIV outpatient clinic at ITM. Accuracy and precision of CD4 T cell counting on fresh EDTA anticoagulated venous blood samples were assessed in the laboratory on a Muse Auto CD4/CD4% system. Extensive precision analyses were performed both on fresh blood and on normal and low stabilized whole blood controls. Accuracy ((bias) was assessed by comparing results from Muse CD4/CD4% to the reference (single-platform FACSCalibur). Clinical misclassification was measured at 500, 350, 200 and 100 cells/μL thresholds. RESULTS: Intra-assay precision was < 5%, and inter-assay was < 9%. CD4 T cell counts measured on Muse Auto CD4/CD4% System and on the reference instrument resulted in regression slopes of 0.97 for absolute counts and 1.03 for CD4 T cell percentages and a correlation coefficient of 0.99 for both. The average absolute bias as compared to the reference was negligible (4 cells/μL or 0.5%). The absolute average bias on CD4 T cell percentages was < 1%. Clinical misclassification at different CD4 T cell thresholds was small resulting in sensitivities and specificities equal or >90% at all thresholds except at 100 cells/μL (sensitivity = 87%). All samples could be analyzed as there was no repetitive rejection errors recorded. CONCLUSIONS: The Muse Auto CD4/CD4% System performed very well on fresh venous blood samples and met all WHO acceptance criteria for analytical performance of CD4 technologies. Public Library of Science 2019-01-23 /pmc/articles/PMC6343963/ /pubmed/30673713 http://dx.doi.org/10.1371/journal.pone.0209677 Text en © 2019 Ceulemans et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Ceulemans, Ann Bouzahzah, Chaymae Prat, Irena Urassa, Willy Kestens, Luc CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics |
title | CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics |
title_full | CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics |
title_fullStr | CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics |
title_full_unstemmed | CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics |
title_short | CD4-T cell enumeration in human immunodeficiency virus (HIV)-infected patients: A laboratory performance evaluation of Muse Auto CD4/CD4% system by World Health Organization prequalification of in vitro diagnostics |
title_sort | cd4-t cell enumeration in human immunodeficiency virus (hiv)-infected patients: a laboratory performance evaluation of muse auto cd4/cd4% system by world health organization prequalification of in vitro diagnostics |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343963/ https://www.ncbi.nlm.nih.gov/pubmed/30673713 http://dx.doi.org/10.1371/journal.pone.0209677 |
work_keys_str_mv | AT ceulemansann cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics AT bouzahzahchaymae cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics AT pratirena cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics AT urassawilly cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics AT kestensluc cd4tcellenumerationinhumanimmunodeficiencyvirushivinfectedpatientsalaboratoryperformanceevaluationofmuseautocd4cd4systembyworldhealthorganizationprequalificationofinvitrodiagnostics |