Cargando…
Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures
BACKGROUND: This study was aimed to evaluate the influence of inter-implant distance on the wear characteristics of low-profile stud attachments used in mandibular implant retained overdentures. MATERIAL AND METHODS: Forty Completely edentulous participants aged between 50 – 70 years were enrolled i...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343987/ https://www.ncbi.nlm.nih.gov/pubmed/30697392 http://dx.doi.org/10.4317/jced.55433 |
_version_ | 1783389363465355264 |
---|---|
author | El Mekawy, Nesreen Elhawary, Mohamed-Yosry |
author_facet | El Mekawy, Nesreen Elhawary, Mohamed-Yosry |
author_sort | El Mekawy, Nesreen |
collection | PubMed |
description | BACKGROUND: This study was aimed to evaluate the influence of inter-implant distance on the wear characteristics of low-profile stud attachments used in mandibular implant retained overdentures. MATERIAL AND METHODS: Forty Completely edentulous participants aged between 50 – 70 years were enrolled in this study. Each patient received 2-implants by 2-stage submerged surgical protocol. Participants categorized into 4-groups. Group I: 19 mm inter-implant distance with Locator retained overdentures; Group II: 19 mm inter-implant distance with OT Equator retained overdentures; Group III: 25 mm inter-implant distance with Locator retained overdentures; Group IV: 25 mm inter-implant distance with OT Equator retained overdentures. The female housings of each attachment were picked up to the mandibular overdenture. 12 month later the male inserts were replaced by new one. The used retentive male inserts were examined by Stereomicroscopic. RESULTS: Stereomicroscopic examination revealed wear were detected on both inner surface and, the core of male inserts. Comparison between the unused and the used Locator and OT equator retentive male inserts at various inter-implant distance revealed highly significant wear changes between them at either 19 mm, or 25 mm inter-implant distance P1= .000, P2=.000 respectively. CONCLUSIONS: After one year of implant overdenture clinical use; both locator and OT equator retentive male inserts revealed significant surface deformities and wear. Wear were more notable on both locator and OT equator retentive male inserts with 25 mm interimplant distance than with 19 mm interimplant distance. Key words:Inter-implant distance, attachments wear, locator retentive male inserts, OT equator retentive male inserts. |
format | Online Article Text |
id | pubmed-6343987 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-63439872019-01-29 Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures El Mekawy, Nesreen Elhawary, Mohamed-Yosry J Clin Exp Dent Research BACKGROUND: This study was aimed to evaluate the influence of inter-implant distance on the wear characteristics of low-profile stud attachments used in mandibular implant retained overdentures. MATERIAL AND METHODS: Forty Completely edentulous participants aged between 50 – 70 years were enrolled in this study. Each patient received 2-implants by 2-stage submerged surgical protocol. Participants categorized into 4-groups. Group I: 19 mm inter-implant distance with Locator retained overdentures; Group II: 19 mm inter-implant distance with OT Equator retained overdentures; Group III: 25 mm inter-implant distance with Locator retained overdentures; Group IV: 25 mm inter-implant distance with OT Equator retained overdentures. The female housings of each attachment were picked up to the mandibular overdenture. 12 month later the male inserts were replaced by new one. The used retentive male inserts were examined by Stereomicroscopic. RESULTS: Stereomicroscopic examination revealed wear were detected on both inner surface and, the core of male inserts. Comparison between the unused and the used Locator and OT equator retentive male inserts at various inter-implant distance revealed highly significant wear changes between them at either 19 mm, or 25 mm inter-implant distance P1= .000, P2=.000 respectively. CONCLUSIONS: After one year of implant overdenture clinical use; both locator and OT equator retentive male inserts revealed significant surface deformities and wear. Wear were more notable on both locator and OT equator retentive male inserts with 25 mm interimplant distance than with 19 mm interimplant distance. Key words:Inter-implant distance, attachments wear, locator retentive male inserts, OT equator retentive male inserts. Medicina Oral S.L. 2019-01-01 /pmc/articles/PMC6343987/ /pubmed/30697392 http://dx.doi.org/10.4317/jced.55433 Text en Copyright: © 2019 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research El Mekawy, Nesreen Elhawary, Mohamed-Yosry Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures |
title | Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures |
title_full | Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures |
title_fullStr | Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures |
title_full_unstemmed | Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures |
title_short | Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures |
title_sort | clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343987/ https://www.ncbi.nlm.nih.gov/pubmed/30697392 http://dx.doi.org/10.4317/jced.55433 |
work_keys_str_mv | AT elmekawynesreen clinicalevaluationofinterimplantdistanceinfluenceonthewearcharacteristicsoflowprofilestudattachmentsusedinmandibularimplantretainedoverdentures AT elhawarymohamedyosry clinicalevaluationofinterimplantdistanceinfluenceonthewearcharacteristicsoflowprofilestudattachmentsusedinmandibularimplantretainedoverdentures |