Cargando…
Efficacy of swm appliance in the expression of first-, second- and third-order information in Class I and Class II
BACKGROUND: To assess the efficacy of a multibracket appliance—Straight-wire Mirabella (SWM) prescription—in terms of achieving the ideal first-, second- and third-order values proposed by Andrews. MATERIAL AND METHODS: A total sample of 46 Caucasian subjects was divided into two groups: 23 with cla...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343997/ https://www.ncbi.nlm.nih.gov/pubmed/30697401 http://dx.doi.org/10.4317/jced.55399 |
_version_ | 1783389365848768512 |
---|---|
author | Lombardo, Luca Calabrò, Michele Squarci, Virginia Colonna, Anna Siciliani, Giuseppe |
author_facet | Lombardo, Luca Calabrò, Michele Squarci, Virginia Colonna, Anna Siciliani, Giuseppe |
author_sort | Lombardo, Luca |
collection | PubMed |
description | BACKGROUND: To assess the efficacy of a multibracket appliance—Straight-wire Mirabella (SWM) prescription—in terms of achieving the ideal first-, second- and third-order values proposed by Andrews. MATERIAL AND METHODS: A total sample of 46 Caucasian subjects was divided into two groups: 23 with class I malocclusion (Group 1), and 23 with class II malocclusion (Group 2). The treatment protocol involved fixed multibracket appliances—SWM prescription—for both groups, with the addition of class II elastics for Group 2. Values for ΔU1-PP, ΔIMPA, in-out, tip and torque were measured on digital scans, and the results obtained were compared with the ideal values proposed by Andrews. RESULTS: Statistically significant differences were revealed between the entire sample and Andrews’ values for: in-out on upper lateral incisors and upper canines; tip on the upper first premolars, upper second premolars, upper first molars and upper canines; and torque on the lower central incisors, lower lateral incisors, lower canines and lower first premolars. However, comparison of Groups 1 and 2 revealed statistically significant differences only at the lower lateral incisors. The use of class II elastics influenced ΔIMPA values, but not ΔU1-PP. CONCLUSIONS: The efficacy of the multibracket appliance—SWM prescription—in expressing first- second- and, to a lesser extent, third-order information was demonstrated in both class I and class II malocclusions. Class II elastics only influenced the third-order expression on the lower lateral incisors and the ΔIMPA. Key words:Straight wire fixed appliances, prescription efficacy, Class I malocclusions, Class II malocclusions. |
format | Online Article Text |
id | pubmed-6343997 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-63439972019-01-29 Efficacy of swm appliance in the expression of first-, second- and third-order information in Class I and Class II Lombardo, Luca Calabrò, Michele Squarci, Virginia Colonna, Anna Siciliani, Giuseppe J Clin Exp Dent Case Report BACKGROUND: To assess the efficacy of a multibracket appliance—Straight-wire Mirabella (SWM) prescription—in terms of achieving the ideal first-, second- and third-order values proposed by Andrews. MATERIAL AND METHODS: A total sample of 46 Caucasian subjects was divided into two groups: 23 with class I malocclusion (Group 1), and 23 with class II malocclusion (Group 2). The treatment protocol involved fixed multibracket appliances—SWM prescription—for both groups, with the addition of class II elastics for Group 2. Values for ΔU1-PP, ΔIMPA, in-out, tip and torque were measured on digital scans, and the results obtained were compared with the ideal values proposed by Andrews. RESULTS: Statistically significant differences were revealed between the entire sample and Andrews’ values for: in-out on upper lateral incisors and upper canines; tip on the upper first premolars, upper second premolars, upper first molars and upper canines; and torque on the lower central incisors, lower lateral incisors, lower canines and lower first premolars. However, comparison of Groups 1 and 2 revealed statistically significant differences only at the lower lateral incisors. The use of class II elastics influenced ΔIMPA values, but not ΔU1-PP. CONCLUSIONS: The efficacy of the multibracket appliance—SWM prescription—in expressing first- second- and, to a lesser extent, third-order information was demonstrated in both class I and class II malocclusions. Class II elastics only influenced the third-order expression on the lower lateral incisors and the ΔIMPA. Key words:Straight wire fixed appliances, prescription efficacy, Class I malocclusions, Class II malocclusions. Medicina Oral S.L. 2019-01-01 /pmc/articles/PMC6343997/ /pubmed/30697401 http://dx.doi.org/10.4317/jced.55399 Text en Copyright: © 2019 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Lombardo, Luca Calabrò, Michele Squarci, Virginia Colonna, Anna Siciliani, Giuseppe Efficacy of swm appliance in the expression of first-, second- and third-order information in Class I and Class II |
title | Efficacy of swm appliance in the expression of first-, second-
and third-order information in Class I and Class II |
title_full | Efficacy of swm appliance in the expression of first-, second-
and third-order information in Class I and Class II |
title_fullStr | Efficacy of swm appliance in the expression of first-, second-
and third-order information in Class I and Class II |
title_full_unstemmed | Efficacy of swm appliance in the expression of first-, second-
and third-order information in Class I and Class II |
title_short | Efficacy of swm appliance in the expression of first-, second-
and third-order information in Class I and Class II |
title_sort | efficacy of swm appliance in the expression of first-, second-
and third-order information in class i and class ii |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6343997/ https://www.ncbi.nlm.nih.gov/pubmed/30697401 http://dx.doi.org/10.4317/jced.55399 |
work_keys_str_mv | AT lombardoluca efficacyofswmapplianceintheexpressionoffirstsecondandthirdorderinformationinclassiandclassii AT calabromichele efficacyofswmapplianceintheexpressionoffirstsecondandthirdorderinformationinclassiandclassii AT squarcivirginia efficacyofswmapplianceintheexpressionoffirstsecondandthirdorderinformationinclassiandclassii AT colonnaanna efficacyofswmapplianceintheexpressionoffirstsecondandthirdorderinformationinclassiandclassii AT sicilianigiuseppe efficacyofswmapplianceintheexpressionoffirstsecondandthirdorderinformationinclassiandclassii |