Neutron visualization of inhomogeneous buried interfaces in thin films

When designing some functions in thin film systems, one of the key concepts is the structure of the constituent layers and interfaces. In an actual system, the layers and interfaces are often inhomogeneous in different scales, from hundreds of microns to several nanometers, causing differences in pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Sakurai, Kenji, Jiang, Jinxing, Mizusawa, Mari, Ito, Takayoshi, Akutsu, Kazuhiro, Miyata, Noboru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6345982/
https://www.ncbi.nlm.nih.gov/pubmed/30679617
http://dx.doi.org/10.1038/s41598-018-37094-5
_version_ 1783389672290910208
author Sakurai, Kenji
Jiang, Jinxing
Mizusawa, Mari
Ito, Takayoshi
Akutsu, Kazuhiro
Miyata, Noboru
author_facet Sakurai, Kenji
Jiang, Jinxing
Mizusawa, Mari
Ito, Takayoshi
Akutsu, Kazuhiro
Miyata, Noboru
author_sort Sakurai, Kenji
collection PubMed
description When designing some functions in thin film systems, one of the key concepts is the structure of the constituent layers and interfaces. In an actual system, the layers and interfaces are often inhomogeneous in different scales, from hundreds of microns to several nanometers, causing differences in properties, despite very similar average structures. In this case, the choice of the observation point is critical to clarify the problem. Another critical aspect is the identification of these points by surveying the entire inhomogeneous thin film system. This article presents a description of a novel promising solution that is suitable for nondestructive visualization of inhomogeneous buried layers and interfaces in thin films. Such observations have been impossible until now. In this investigation, a unique extension of neutron reflectometry is proposed. While conventional neutron reflectivity just gives average depth-profiling of the scattering length density of layered thin films, the present method provides full picture of the inhomogeneity. In general, achieving a high spatial-resolving power for neutron scattering is not straightforward because the neutron counts become fairly limited at the sample or the detector position when the beam size is reduced. As a result, XY scanning of a sample with a small neutron beam is fairly difficult because of the required long measurement time. To address these issues, new concepts have been introduced for neutron reflectivity. The proposed method uses a wide beam instead of reducing the beam size. In addition, it measures the projection reflection profile instead of the total integrated intensity. These profiles are collected at a set of different in-plane angles. Similar to computed tomography, it is possible to obtain the specimen’s two-dimensional (2D) neutron reflectivity distribution as one image. Because the spatial resolution is limited by the detection method, a Hadamard coded mask is employed to measure the reflection projection with only 50% loss of the primary neutron intensity. When the time-of-flight (ToF) mode is used for the neutron experiment, one can obtain many images as a function of ToF, i.e., the wavevector transfer. Such series of images can be displayed as a video. This indicates that the neutron reflectivity profiles of local points can be retrieved from the above video images. This paper presents the first report on the development of neutron reflectivity with imaging capability, and the analysis of local points in inhomogeneous layered thin-films without utilizing a small neutron beam. In the present work, the feasibility of the proposed method with approximately 1 mm spatial resolution was examined. In addition, further improvements of the approach are discussed. It is anticipated that this technique will facilitate new opportunities in the study of buried function interfaces.
format Online
Article
Text
id pubmed-6345982
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-63459822019-01-29 Neutron visualization of inhomogeneous buried interfaces in thin films Sakurai, Kenji Jiang, Jinxing Mizusawa, Mari Ito, Takayoshi Akutsu, Kazuhiro Miyata, Noboru Sci Rep Article When designing some functions in thin film systems, one of the key concepts is the structure of the constituent layers and interfaces. In an actual system, the layers and interfaces are often inhomogeneous in different scales, from hundreds of microns to several nanometers, causing differences in properties, despite very similar average structures. In this case, the choice of the observation point is critical to clarify the problem. Another critical aspect is the identification of these points by surveying the entire inhomogeneous thin film system. This article presents a description of a novel promising solution that is suitable for nondestructive visualization of inhomogeneous buried layers and interfaces in thin films. Such observations have been impossible until now. In this investigation, a unique extension of neutron reflectometry is proposed. While conventional neutron reflectivity just gives average depth-profiling of the scattering length density of layered thin films, the present method provides full picture of the inhomogeneity. In general, achieving a high spatial-resolving power for neutron scattering is not straightforward because the neutron counts become fairly limited at the sample or the detector position when the beam size is reduced. As a result, XY scanning of a sample with a small neutron beam is fairly difficult because of the required long measurement time. To address these issues, new concepts have been introduced for neutron reflectivity. The proposed method uses a wide beam instead of reducing the beam size. In addition, it measures the projection reflection profile instead of the total integrated intensity. These profiles are collected at a set of different in-plane angles. Similar to computed tomography, it is possible to obtain the specimen’s two-dimensional (2D) neutron reflectivity distribution as one image. Because the spatial resolution is limited by the detection method, a Hadamard coded mask is employed to measure the reflection projection with only 50% loss of the primary neutron intensity. When the time-of-flight (ToF) mode is used for the neutron experiment, one can obtain many images as a function of ToF, i.e., the wavevector transfer. Such series of images can be displayed as a video. This indicates that the neutron reflectivity profiles of local points can be retrieved from the above video images. This paper presents the first report on the development of neutron reflectivity with imaging capability, and the analysis of local points in inhomogeneous layered thin-films without utilizing a small neutron beam. In the present work, the feasibility of the proposed method with approximately 1 mm spatial resolution was examined. In addition, further improvements of the approach are discussed. It is anticipated that this technique will facilitate new opportunities in the study of buried function interfaces. Nature Publishing Group UK 2019-01-24 /pmc/articles/PMC6345982/ /pubmed/30679617 http://dx.doi.org/10.1038/s41598-018-37094-5 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Sakurai, Kenji
Jiang, Jinxing
Mizusawa, Mari
Ito, Takayoshi
Akutsu, Kazuhiro
Miyata, Noboru
Neutron visualization of inhomogeneous buried interfaces in thin films
title Neutron visualization of inhomogeneous buried interfaces in thin films
title_full Neutron visualization of inhomogeneous buried interfaces in thin films
title_fullStr Neutron visualization of inhomogeneous buried interfaces in thin films
title_full_unstemmed Neutron visualization of inhomogeneous buried interfaces in thin films
title_short Neutron visualization of inhomogeneous buried interfaces in thin films
title_sort neutron visualization of inhomogeneous buried interfaces in thin films
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6345982/
https://www.ncbi.nlm.nih.gov/pubmed/30679617
http://dx.doi.org/10.1038/s41598-018-37094-5
work_keys_str_mv AT sakuraikenji neutronvisualizationofinhomogeneousburiedinterfacesinthinfilms
AT jiangjinxing neutronvisualizationofinhomogeneousburiedinterfacesinthinfilms
AT mizusawamari neutronvisualizationofinhomogeneousburiedinterfacesinthinfilms
AT itotakayoshi neutronvisualizationofinhomogeneousburiedinterfacesinthinfilms
AT akutsukazuhiro neutronvisualizationofinhomogeneousburiedinterfacesinthinfilms
AT miyatanoboru neutronvisualizationofinhomogeneousburiedinterfacesinthinfilms