Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging

Long-term stability of endosseous implants depends on successful bone formation, ingrowth and adaptation to the implant. Specifically, it will define the mechanical properties of the newly formed bone-implant interface. 3D imaging during mechanical loading tests (in situ loading) can improve the und...

Descripción completa

Detalles Bibliográficos
Autores principales: Le Cann, Sophie, Tudisco, Erika, Turunen, Mikael J., Patera, Alessandra, Mokso, Rajmund, Tägil, Magnus, Belfrage, Ola, Hall, Stephen A., Isaksson, Hanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6348316/
https://www.ncbi.nlm.nih.gov/pubmed/30719433
http://dx.doi.org/10.3389/fbioe.2018.00208
_version_ 1783390078661296128
author Le Cann, Sophie
Tudisco, Erika
Turunen, Mikael J.
Patera, Alessandra
Mokso, Rajmund
Tägil, Magnus
Belfrage, Ola
Hall, Stephen A.
Isaksson, Hanna
author_facet Le Cann, Sophie
Tudisco, Erika
Turunen, Mikael J.
Patera, Alessandra
Mokso, Rajmund
Tägil, Magnus
Belfrage, Ola
Hall, Stephen A.
Isaksson, Hanna
author_sort Le Cann, Sophie
collection PubMed
description Long-term stability of endosseous implants depends on successful bone formation, ingrowth and adaptation to the implant. Specifically, it will define the mechanical properties of the newly formed bone-implant interface. 3D imaging during mechanical loading tests (in situ loading) can improve the understanding of the local processes leading to bone damage and failure. In this study, titanium screws were implanted into rat tibiae and were allowed to integrate for 4 weeks with or without the addition of the growth factor Bone Morphogenetic Protein and the bisphosphonate Zoledronic Acid. Samples were subjected to in situ pullout using high-resolution synchrotron x-ray tomography at the Tomcat beamline (SLS, PSI, Switzerland) at 30 keV with 25 ms exposure time, resulting in a total acquisition time of 45 s per scan, with a 3.6 μm isotropic voxel size. Using a custom-made loading device positioned inside the beamline, screws were pulled out with 0.05 mm increment, acquiring multiple scans until rupture of the sample. The in situ loading protocol was adapted to ensure short imaging time, which enabled multiple samples to be tested with short loading steps, while keeping the total testing time low and reducing dose deposition. Higher trabecular bone content was quantified in the surrounding of the screw in the treated groups, which correlated with increased mechanical strength and stiffness. Differences in screw implantation, such as contact between threads and cortex as well as minor tilt of the screw were also correlated to the mechanical parameters. In situ loading enabled the investigation of crack propagation during the pullout, highlighting the mechanical behavior of the interface. Three typical crack types were observed: (1) rupture at the interface of trabecular and cortical bone tissues, close to the screw, (2) large crack inside the cortex connected to the implant, and (3) first failure away from the screw with cracks propagating toward the screw-bone interface. Mechanical properties of in vivo integrated bone-metal screws rely on a combination of multiple parameters that are difficult to identify and separate one from the other.
format Online
Article
Text
id pubmed-6348316
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-63483162019-02-04 Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging Le Cann, Sophie Tudisco, Erika Turunen, Mikael J. Patera, Alessandra Mokso, Rajmund Tägil, Magnus Belfrage, Ola Hall, Stephen A. Isaksson, Hanna Front Bioeng Biotechnol Bioengineering and Biotechnology Long-term stability of endosseous implants depends on successful bone formation, ingrowth and adaptation to the implant. Specifically, it will define the mechanical properties of the newly formed bone-implant interface. 3D imaging during mechanical loading tests (in situ loading) can improve the understanding of the local processes leading to bone damage and failure. In this study, titanium screws were implanted into rat tibiae and were allowed to integrate for 4 weeks with or without the addition of the growth factor Bone Morphogenetic Protein and the bisphosphonate Zoledronic Acid. Samples were subjected to in situ pullout using high-resolution synchrotron x-ray tomography at the Tomcat beamline (SLS, PSI, Switzerland) at 30 keV with 25 ms exposure time, resulting in a total acquisition time of 45 s per scan, with a 3.6 μm isotropic voxel size. Using a custom-made loading device positioned inside the beamline, screws were pulled out with 0.05 mm increment, acquiring multiple scans until rupture of the sample. The in situ loading protocol was adapted to ensure short imaging time, which enabled multiple samples to be tested with short loading steps, while keeping the total testing time low and reducing dose deposition. Higher trabecular bone content was quantified in the surrounding of the screw in the treated groups, which correlated with increased mechanical strength and stiffness. Differences in screw implantation, such as contact between threads and cortex as well as minor tilt of the screw were also correlated to the mechanical parameters. In situ loading enabled the investigation of crack propagation during the pullout, highlighting the mechanical behavior of the interface. Three typical crack types were observed: (1) rupture at the interface of trabecular and cortical bone tissues, close to the screw, (2) large crack inside the cortex connected to the implant, and (3) first failure away from the screw with cracks propagating toward the screw-bone interface. Mechanical properties of in vivo integrated bone-metal screws rely on a combination of multiple parameters that are difficult to identify and separate one from the other. Frontiers Media S.A. 2019-01-21 /pmc/articles/PMC6348316/ /pubmed/30719433 http://dx.doi.org/10.3389/fbioe.2018.00208 Text en Copyright © 2019 Le Cann, Tudisco, Turunen, Patera, Mokso, Tägil, Belfrage, Hall and Isaksson. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Le Cann, Sophie
Tudisco, Erika
Turunen, Mikael J.
Patera, Alessandra
Mokso, Rajmund
Tägil, Magnus
Belfrage, Ola
Hall, Stephen A.
Isaksson, Hanna
Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging
title Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging
title_full Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging
title_fullStr Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging
title_full_unstemmed Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging
title_short Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging
title_sort investigating the mechanical characteristics of bone-metal implant interface using in situ synchrotron tomographic imaging
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6348316/
https://www.ncbi.nlm.nih.gov/pubmed/30719433
http://dx.doi.org/10.3389/fbioe.2018.00208
work_keys_str_mv AT lecannsophie investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging
AT tudiscoerika investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging
AT turunenmikaelj investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging
AT pateraalessandra investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging
AT moksorajmund investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging
AT tagilmagnus investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging
AT belfrageola investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging
AT hallstephena investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging
AT isakssonhanna investigatingthemechanicalcharacteristicsofbonemetalimplantinterfaceusinginsitusynchrotrontomographicimaging