Cargando…
Preoperative Ultrasound Evaluation of the Semitendinosus Tendon for Anterior Cruciate Ligament Reconstruction
BACKGROUND: Adequate graft size and length are crucial factors that correlate with improved outcomes after anterior cruciate ligament reconstruction with a semitendinosus (ST) tendon autograft alone. Anthropometric parameters could be used as predictors of graft measurements but they have shown impr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6348512/ https://www.ncbi.nlm.nih.gov/pubmed/30719480 http://dx.doi.org/10.1177/2325967118822318 |
_version_ | 1783390113117503488 |
---|---|
author | Sumanont, Sermsak Mahaweerawat, Chatchada Boonrod, Arunnit Thammaroj, Punthip Boonrod, Artit |
author_facet | Sumanont, Sermsak Mahaweerawat, Chatchada Boonrod, Arunnit Thammaroj, Punthip Boonrod, Artit |
author_sort | Sumanont, Sermsak |
collection | PubMed |
description | BACKGROUND: Adequate graft size and length are crucial factors that correlate with improved outcomes after anterior cruciate ligament reconstruction with a semitendinosus (ST) tendon autograft alone. Anthropometric parameters could be used as predictors of graft measurements but they have shown imprecise correlation in some patients. PURPOSE: To evaluate the accuracy of ultrasound (US) for the preoperative evaluation of ST graft size and length. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 3. METHODS: A total of 40 patients were included in this study. Patient sex, age, anthropometric parameters, and preoperative US measurements were recorded. After the ST tendons were harvested, their lengths as well as the diameters of the 4-strand ST grafts were recorded. Correlations between patient US measurements were analyzed. Inadequate ST graft length was defined at <28 cm, and inadequate 4-strand ST graft diameter was defined at <8 mm. RESULTS: The prevalence of patients with an ST graft length <28 cm was 47.5%, and the prevalence of patients with a 4-strand ST graft diameter <8 mm was 42.5%. US measurements had a strong, significant correlation with the ST graft length (P < .001) and a moderate correlation with the 4-strand ST graft diameter (P < .001). Absolute agreement between the preoperative US measurement of ST graft length and the intraoperative ST graft length showed good reliability (ICC(2,1) = 0.825). The cross-sectional area (CSA) of the ST tendon at the knee joint level by US showed a weak correlation (r = 0.207) with the 4-strand ST graft diameter (P = .200). A CSA of 16 mm(2) measured by US could be used to predict a 4-strand ST graft diameter ≥8 mm, with a sensitivity of 73.9% and specificity of 76.5%. CONCLUSION: Preoperative US measurements of ST tendons had a strong correlation with intraoperative ST graft length and provided good sensitivity to detect a 4-strand ST graft diameter ≥8 mm. All other anthropometric parameters showed a weak to moderate correlation with ST graft length and size. |
format | Online Article Text |
id | pubmed-6348512 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-63485122019-02-04 Preoperative Ultrasound Evaluation of the Semitendinosus Tendon for Anterior Cruciate Ligament Reconstruction Sumanont, Sermsak Mahaweerawat, Chatchada Boonrod, Arunnit Thammaroj, Punthip Boonrod, Artit Orthop J Sports Med Article BACKGROUND: Adequate graft size and length are crucial factors that correlate with improved outcomes after anterior cruciate ligament reconstruction with a semitendinosus (ST) tendon autograft alone. Anthropometric parameters could be used as predictors of graft measurements but they have shown imprecise correlation in some patients. PURPOSE: To evaluate the accuracy of ultrasound (US) for the preoperative evaluation of ST graft size and length. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 3. METHODS: A total of 40 patients were included in this study. Patient sex, age, anthropometric parameters, and preoperative US measurements were recorded. After the ST tendons were harvested, their lengths as well as the diameters of the 4-strand ST grafts were recorded. Correlations between patient US measurements were analyzed. Inadequate ST graft length was defined at <28 cm, and inadequate 4-strand ST graft diameter was defined at <8 mm. RESULTS: The prevalence of patients with an ST graft length <28 cm was 47.5%, and the prevalence of patients with a 4-strand ST graft diameter <8 mm was 42.5%. US measurements had a strong, significant correlation with the ST graft length (P < .001) and a moderate correlation with the 4-strand ST graft diameter (P < .001). Absolute agreement between the preoperative US measurement of ST graft length and the intraoperative ST graft length showed good reliability (ICC(2,1) = 0.825). The cross-sectional area (CSA) of the ST tendon at the knee joint level by US showed a weak correlation (r = 0.207) with the 4-strand ST graft diameter (P = .200). A CSA of 16 mm(2) measured by US could be used to predict a 4-strand ST graft diameter ≥8 mm, with a sensitivity of 73.9% and specificity of 76.5%. CONCLUSION: Preoperative US measurements of ST tendons had a strong correlation with intraoperative ST graft length and provided good sensitivity to detect a 4-strand ST graft diameter ≥8 mm. All other anthropometric parameters showed a weak to moderate correlation with ST graft length and size. SAGE Publications 2019-01-23 /pmc/articles/PMC6348512/ /pubmed/30719480 http://dx.doi.org/10.1177/2325967118822318 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (http://www.creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Article Sumanont, Sermsak Mahaweerawat, Chatchada Boonrod, Arunnit Thammaroj, Punthip Boonrod, Artit Preoperative Ultrasound Evaluation of the Semitendinosus Tendon for Anterior Cruciate Ligament Reconstruction |
title | Preoperative Ultrasound Evaluation of the Semitendinosus Tendon for Anterior Cruciate Ligament Reconstruction |
title_full | Preoperative Ultrasound Evaluation of the Semitendinosus Tendon for Anterior Cruciate Ligament Reconstruction |
title_fullStr | Preoperative Ultrasound Evaluation of the Semitendinosus Tendon for Anterior Cruciate Ligament Reconstruction |
title_full_unstemmed | Preoperative Ultrasound Evaluation of the Semitendinosus Tendon for Anterior Cruciate Ligament Reconstruction |
title_short | Preoperative Ultrasound Evaluation of the Semitendinosus Tendon for Anterior Cruciate Ligament Reconstruction |
title_sort | preoperative ultrasound evaluation of the semitendinosus tendon for anterior cruciate ligament reconstruction |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6348512/ https://www.ncbi.nlm.nih.gov/pubmed/30719480 http://dx.doi.org/10.1177/2325967118822318 |
work_keys_str_mv | AT sumanontsermsak preoperativeultrasoundevaluationofthesemitendinosustendonforanteriorcruciateligamentreconstruction AT mahaweerawatchatchada preoperativeultrasoundevaluationofthesemitendinosustendonforanteriorcruciateligamentreconstruction AT boonrodarunnit preoperativeultrasoundevaluationofthesemitendinosustendonforanteriorcruciateligamentreconstruction AT thammarojpunthip preoperativeultrasoundevaluationofthesemitendinosustendonforanteriorcruciateligamentreconstruction AT boonrodartit preoperativeultrasoundevaluationofthesemitendinosustendonforanteriorcruciateligamentreconstruction |