PURPOSE: We hypothesized that the interfraction motions of the superior and inferior prostate beds differ and therefore require different margins. In this study, we used daily cone beam computed tomography (CBCT) to evaluate the motion of postprostatectomy surgical clips (separated to superior and i...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Haijun, Salama, Joseph K., Lee, William Robert, Wu, Qiuwen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6349621/
https://www.ncbi.nlm.nih.gov/pubmed/30706027
http://dx.doi.org/10.1016/j.adro.2018.09.014
_version_ 1783390288963698688
author Song, Haijun
Salama, Joseph K.
Lee, William Robert
Wu, Qiuwen
author_facet Song, Haijun
Salama, Joseph K.
Lee, William Robert
Wu, Qiuwen
author_sort Song, Haijun
collection PubMed
description PURPOSE: We hypothesized that the interfraction motions of the superior and inferior prostate beds differ and therefore require different margins. In this study, we used daily cone beam computed tomography (CBCT) to evaluate the motion of postprostatectomy surgical clips (separated to superior and inferior portions) within the planning target volume (PTV) to derive data-driven PTV margins. METHODS AND MATERIALS: Our study cohort included consecutive patients with identifiable surgical clips undergoing prostate bed irradiation with daily CBCT image guidance. We identified and contoured the clips within the PTV on the planning computed tomography and CBCT scans. All CBCT scans were registered to the planning computed tomography scan on the basis of pelvic bony structures. The superior border of the pubic symphysis was used to mark the division between the superior and inferior portions. RESULTS: Eleven patients with 263 CBCT scans were included in the cohort. In the left–right direction, the global mean M, systematic error Σ, and residue error σ were 0.02, 0.03, and 0.16 cm, respectively, for superior clips, and 0.00, 0.03, and 0.03 cm, respectively, for inferior clips. In the anterior–posterior direction, the corresponding values were M = 0.01, Σ = 0.25, and σ= 0.37, respectively, for superior, and M = 0.08, Σ= 0.13, σ= 0.15, respectively, for inferior. In the superior–inferior direction, the values were M =-0.06, Σ= 0.23, and σ= 0.27, respectively, for superior, and M =-0.01, Σ= 0.21, σ= 0.20, respectively, for inferior. The results of the 2-tailed F tests showed that the anterior–posterior motion is statistically different between the superior and inferior portions in the anterior–posterior direction. There is no statistical difference in the superior–inferior and lateral directions. Therefore, we propose a set of nonuniform PTV margins (based on the formula 2.5 Σ+ 0.7σ) as 0.2 cm for all prostate beds in the left–right direction, 0.7 cm for all in superior–inferior, and 0.9 to 0.4 for superior–inferior in the anterior–posterior direction. CONCLUSIONS: The difference in motion between the superior and inferior portions of the prostate bed is statistically insignificant in the left–right and superior–inferior directions, but statistically significant in the anterior–posterior direction, which warrants a nonuniform PTV margin scheme.
format Online
Article
Text
id pubmed-6349621
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-63496212019-01-31 Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography Song, Haijun Salama, Joseph K. Lee, William Robert Wu, Qiuwen Adv Radiat Oncol Physics Contribution PURPOSE: We hypothesized that the interfraction motions of the superior and inferior prostate beds differ and therefore require different margins. In this study, we used daily cone beam computed tomography (CBCT) to evaluate the motion of postprostatectomy surgical clips (separated to superior and inferior portions) within the planning target volume (PTV) to derive data-driven PTV margins. METHODS AND MATERIALS: Our study cohort included consecutive patients with identifiable surgical clips undergoing prostate bed irradiation with daily CBCT image guidance. We identified and contoured the clips within the PTV on the planning computed tomography and CBCT scans. All CBCT scans were registered to the planning computed tomography scan on the basis of pelvic bony structures. The superior border of the pubic symphysis was used to mark the division between the superior and inferior portions. RESULTS: Eleven patients with 263 CBCT scans were included in the cohort. In the left–right direction, the global mean M, systematic error Σ, and residue error σ were 0.02, 0.03, and 0.16 cm, respectively, for superior clips, and 0.00, 0.03, and 0.03 cm, respectively, for inferior clips. In the anterior–posterior direction, the corresponding values were M = 0.01, Σ = 0.25, and σ= 0.37, respectively, for superior, and M = 0.08, Σ= 0.13, σ= 0.15, respectively, for inferior. In the superior–inferior direction, the values were M =-0.06, Σ= 0.23, and σ= 0.27, respectively, for superior, and M =-0.01, Σ= 0.21, σ= 0.20, respectively, for inferior. The results of the 2-tailed F tests showed that the anterior–posterior motion is statistically different between the superior and inferior portions in the anterior–posterior direction. There is no statistical difference in the superior–inferior and lateral directions. Therefore, we propose a set of nonuniform PTV margins (based on the formula 2.5 Σ+ 0.7σ) as 0.2 cm for all prostate beds in the left–right direction, 0.7 cm for all in superior–inferior, and 0.9 to 0.4 for superior–inferior in the anterior–posterior direction. CONCLUSIONS: The difference in motion between the superior and inferior portions of the prostate bed is statistically insignificant in the left–right and superior–inferior directions, but statistically significant in the anterior–posterior direction, which warrants a nonuniform PTV margin scheme. Elsevier 2018-10-12 /pmc/articles/PMC6349621/ /pubmed/30706027 http://dx.doi.org/10.1016/j.adro.2018.09.014 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Physics Contribution
Song, Haijun
Salama, Joseph K.
Lee, William Robert
Wu, Qiuwen
Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography
title Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography
title_full Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography
title_fullStr Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography
title_full_unstemmed Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography
title_short Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography
title_sort nonuniform planning target volume margins for prostate bed on the basis of surgical clips on daily cone beam computed tomography
topic Physics Contribution
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6349621/
https://www.ncbi.nlm.nih.gov/pubmed/30706027
http://dx.doi.org/10.1016/j.adro.2018.09.014
work_keys_str_mv AT songhaijun nonuniformplanningtargetvolumemarginsforprostatebedonthebasisofsurgicalclipsondailyconebeamcomputedtomography
AT salamajosephk nonuniformplanningtargetvolumemarginsforprostatebedonthebasisofsurgicalclipsondailyconebeamcomputedtomography
AT leewilliamrobert nonuniformplanningtargetvolumemarginsforprostatebedonthebasisofsurgicalclipsondailyconebeamcomputedtomography
AT wuqiuwen nonuniformplanningtargetvolumemarginsforprostatebedonthebasisofsurgicalclipsondailyconebeamcomputedtomography