Cargando…

Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases

Purpose: To evaluate the dosimetric performance and planning/delivery efficiency of a dual-layer MLC system for treating multiple brain metastases with a single isocenter. Materials and Methods: 10 patients each with 6–10 targets with volumes from 0.11 to 8.57 cc, and prescription doses from 15 to 2...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Taoran, Irmen, Peyton, Liu, Haisong, Shi, Wenyin, Alonso-Basanta, Michelle, Zou, Wei, Teo, Boon-Keng Kevin, Metz, James M., Dong, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6349708/
https://www.ncbi.nlm.nih.gov/pubmed/30723702
http://dx.doi.org/10.3389/fonc.2019.00007
_version_ 1783390297620742144
author Li, Taoran
Irmen, Peyton
Liu, Haisong
Shi, Wenyin
Alonso-Basanta, Michelle
Zou, Wei
Teo, Boon-Keng Kevin
Metz, James M.
Dong, Lei
author_facet Li, Taoran
Irmen, Peyton
Liu, Haisong
Shi, Wenyin
Alonso-Basanta, Michelle
Zou, Wei
Teo, Boon-Keng Kevin
Metz, James M.
Dong, Lei
author_sort Li, Taoran
collection PubMed
description Purpose: To evaluate the dosimetric performance and planning/delivery efficiency of a dual-layer MLC system for treating multiple brain metastases with a single isocenter. Materials and Methods: 10 patients each with 6–10 targets with volumes from 0.11 to 8.57 cc, and prescription doses from 15 to 24 Gy, were retrospectively studied. Halcyon has only coplanar delivery mode. Halcyon V1 MLC modulates only with the lower layer at 1 cm resolution, whereas V2 MLC modulates with both layers at an effective resolution of 0.5 cm. For each patient five plans were compared varying MLC and beam arrangements: the clinical plan using multi-aperture dynamic conformal arc (DCA) and non-coplanar arcs, Halcyon-V1 using coplanar-VMAT, Halcyon-V2 using coplanar-VMAT, HDMLC-0.25 cm using coplanar-VMAT, and HDMLC-0.25 cm using non-coplanar-VMAT. All same-case plans were generated following the same planning protocol and normalization. Conformity index (CI), gradient index (GI), V12Gy, V6Gy, V3Gy, and brain mean dose were compared. Results: All VMAT plans met clinical constraints for critical structures. For targets with diameter < 1 cm, Halcyon plans showed inferior CI among all techniques. For targets with diameter >1 cm, Halcyon VMAT plans had CI similar to non-coplanar VMAT plans, and better than non-coplanar clinical DCA plans. For GI, Halcyon MLC plans performed similarly to coplanar HDMLC plans and inferiorly compared to non-coplanar HDMLC plans. All coplanar VMAT plans (Halcyon MLC and HDMLC) and clinical DCA plans had similar V12Gy, but were inferior compared to non-coplanar VMAT plans. Halcyon plans had slightly reduced V3Gy and mean brain dose compared to HDMLC plans. The difference between Halcyon V1 and V2 is only significant in CI of tumors less than 1cm in diameter. Halcyon plans required longer optimization than Truebeam VMAT plans, but had similar delivery efficiency. Conclusion: For targets with diameter >1 cm, Halcyon's dual-layer stacked and staggered MLC is capable of producing similar dose conformity compared to HDMLC while reducing low dose spill to normal brain tissue. GI and V12Gy of Halcyon MLC plans were, in general, inferior to non-coplanar DCA or VMAT plans using HDMLC, likely due to coplanar geometry and wider MLC leaves. HDMLC maintained its advantage in CI for smaller targets with diameter <1 cm.
format Online
Article
Text
id pubmed-6349708
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-63497082019-02-05 Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases Li, Taoran Irmen, Peyton Liu, Haisong Shi, Wenyin Alonso-Basanta, Michelle Zou, Wei Teo, Boon-Keng Kevin Metz, James M. Dong, Lei Front Oncol Oncology Purpose: To evaluate the dosimetric performance and planning/delivery efficiency of a dual-layer MLC system for treating multiple brain metastases with a single isocenter. Materials and Methods: 10 patients each with 6–10 targets with volumes from 0.11 to 8.57 cc, and prescription doses from 15 to 24 Gy, were retrospectively studied. Halcyon has only coplanar delivery mode. Halcyon V1 MLC modulates only with the lower layer at 1 cm resolution, whereas V2 MLC modulates with both layers at an effective resolution of 0.5 cm. For each patient five plans were compared varying MLC and beam arrangements: the clinical plan using multi-aperture dynamic conformal arc (DCA) and non-coplanar arcs, Halcyon-V1 using coplanar-VMAT, Halcyon-V2 using coplanar-VMAT, HDMLC-0.25 cm using coplanar-VMAT, and HDMLC-0.25 cm using non-coplanar-VMAT. All same-case plans were generated following the same planning protocol and normalization. Conformity index (CI), gradient index (GI), V12Gy, V6Gy, V3Gy, and brain mean dose were compared. Results: All VMAT plans met clinical constraints for critical structures. For targets with diameter < 1 cm, Halcyon plans showed inferior CI among all techniques. For targets with diameter >1 cm, Halcyon VMAT plans had CI similar to non-coplanar VMAT plans, and better than non-coplanar clinical DCA plans. For GI, Halcyon MLC plans performed similarly to coplanar HDMLC plans and inferiorly compared to non-coplanar HDMLC plans. All coplanar VMAT plans (Halcyon MLC and HDMLC) and clinical DCA plans had similar V12Gy, but were inferior compared to non-coplanar VMAT plans. Halcyon plans had slightly reduced V3Gy and mean brain dose compared to HDMLC plans. The difference between Halcyon V1 and V2 is only significant in CI of tumors less than 1cm in diameter. Halcyon plans required longer optimization than Truebeam VMAT plans, but had similar delivery efficiency. Conclusion: For targets with diameter >1 cm, Halcyon's dual-layer stacked and staggered MLC is capable of producing similar dose conformity compared to HDMLC while reducing low dose spill to normal brain tissue. GI and V12Gy of Halcyon MLC plans were, in general, inferior to non-coplanar DCA or VMAT plans using HDMLC, likely due to coplanar geometry and wider MLC leaves. HDMLC maintained its advantage in CI for smaller targets with diameter <1 cm. Frontiers Media S.A. 2019-01-22 /pmc/articles/PMC6349708/ /pubmed/30723702 http://dx.doi.org/10.3389/fonc.2019.00007 Text en Copyright © 2019 Li, Irmen, Liu, Shi, Alonso-Basanta, Zou, Teo, Metz and Dong. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Li, Taoran
Irmen, Peyton
Liu, Haisong
Shi, Wenyin
Alonso-Basanta, Michelle
Zou, Wei
Teo, Boon-Keng Kevin
Metz, James M.
Dong, Lei
Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases
title Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases
title_full Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases
title_fullStr Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases
title_full_unstemmed Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases
title_short Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases
title_sort dosimetric performance and planning/delivery efficiency of a dual-layer stacked and staggered mlc on treating multiple small targets: a planning study based on single-isocenter multi-target stereotactic radiosurgery (srs) to brain metastases
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6349708/
https://www.ncbi.nlm.nih.gov/pubmed/30723702
http://dx.doi.org/10.3389/fonc.2019.00007
work_keys_str_mv AT litaoran dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases
AT irmenpeyton dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases
AT liuhaisong dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases
AT shiwenyin dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases
AT alonsobasantamichelle dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases
AT zouwei dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases
AT teoboonkengkevin dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases
AT metzjamesm dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases
AT donglei dosimetricperformanceandplanningdeliveryefficiencyofaduallayerstackedandstaggeredmlcontreatingmultiplesmalltargetsaplanningstudybasedonsingleisocentermultitargetstereotacticradiosurgerysrstobrainmetastases