The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system

In elite football, measurement of running kinetics with inertial measurement units (IMUs) may be useful as a component of periodic health examination (PHE). This study determined the reliability of, and agreement between a research orientated IMU and clinically orientated IMU system for initial peak...

Descripción completa

Detalles Bibliográficos
Autores principales: Hughes, Tom, Jones, Richard K., Starbuck, Chelsea, Sergeant, Jamie C., Callaghan, Michael J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6350007/
https://www.ncbi.nlm.nih.gov/pubmed/30658231
http://dx.doi.org/10.1016/j.jelekin.2019.01.001
_version_ 1783390368629260288
author Hughes, Tom
Jones, Richard K.
Starbuck, Chelsea
Sergeant, Jamie C.
Callaghan, Michael J.
author_facet Hughes, Tom
Jones, Richard K.
Starbuck, Chelsea
Sergeant, Jamie C.
Callaghan, Michael J.
author_sort Hughes, Tom
collection PubMed
description In elite football, measurement of running kinetics with inertial measurement units (IMUs) may be useful as a component of periodic health examination (PHE). This study determined the reliability of, and agreement between a research orientated IMU and clinically orientated IMU system for initial peak acceleration (IPA) and IPA symmetry index (SI) measurement during running in elite footballers. On consecutive days, 16 participants performed treadmill running at 14kmph and 18kmph. Both IMUs measured IPA and IPA SI concurrently. All measurements had good or excellent within-session reliability (intraclass correlation coefficient (ICC(2,1)) range = 0.79–0.96, IPA standard error of measurement (SEM) range = 0.19–0.62 g, IPA SI SEM range = 2.50–8.05%). Only the research orientated IMU demonstrated acceptable minimal detectable changes (MDCs) for IPA at 14kmph (range = 7.46–9.80%) and IPA SI at both speeds (range = 6.92–9.21%). Considering both systems, between-session IPA reliability ranged from fair to good (ICC(2,1) range = 0.63–0.87, SEM range = 0.51–1.10 g) and poor to fair for IPA SI (ICC(2,1) range = 0.32–0.65, SEM range = 8.07–11.18%). All MDCs were >10%. For IPA and SI, the 95% levels of agreement indicated poor between system agreement. Therefore, the use of IMUs to evaluate treadmill running kinetics cannot be recommended in this population as a PHE test to identify prognostic factors for injuries or for rehabilitation purposes.
format Online
Article
Text
id pubmed-6350007
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-63500072019-02-01 The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system Hughes, Tom Jones, Richard K. Starbuck, Chelsea Sergeant, Jamie C. Callaghan, Michael J. J Electromyogr Kinesiol Article In elite football, measurement of running kinetics with inertial measurement units (IMUs) may be useful as a component of periodic health examination (PHE). This study determined the reliability of, and agreement between a research orientated IMU and clinically orientated IMU system for initial peak acceleration (IPA) and IPA symmetry index (SI) measurement during running in elite footballers. On consecutive days, 16 participants performed treadmill running at 14kmph and 18kmph. Both IMUs measured IPA and IPA SI concurrently. All measurements had good or excellent within-session reliability (intraclass correlation coefficient (ICC(2,1)) range = 0.79–0.96, IPA standard error of measurement (SEM) range = 0.19–0.62 g, IPA SI SEM range = 2.50–8.05%). Only the research orientated IMU demonstrated acceptable minimal detectable changes (MDCs) for IPA at 14kmph (range = 7.46–9.80%) and IPA SI at both speeds (range = 6.92–9.21%). Considering both systems, between-session IPA reliability ranged from fair to good (ICC(2,1) range = 0.63–0.87, SEM range = 0.51–1.10 g) and poor to fair for IPA SI (ICC(2,1) range = 0.32–0.65, SEM range = 8.07–11.18%). All MDCs were >10%. For IPA and SI, the 95% levels of agreement indicated poor between system agreement. Therefore, the use of IMUs to evaluate treadmill running kinetics cannot be recommended in this population as a PHE test to identify prognostic factors for injuries or for rehabilitation purposes. Elsevier 2019-02 /pmc/articles/PMC6350007/ /pubmed/30658231 http://dx.doi.org/10.1016/j.jelekin.2019.01.001 Text en © 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hughes, Tom
Jones, Richard K.
Starbuck, Chelsea
Sergeant, Jamie C.
Callaghan, Michael J.
The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system
title The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system
title_full The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system
title_fullStr The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system
title_full_unstemmed The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system
title_short The value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. A reliability and agreement study using a research orientated and a clinically orientated system
title_sort value of tibial mounted inertial measurement units to quantify running kinetics in elite football (soccer) players. a reliability and agreement study using a research orientated and a clinically orientated system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6350007/
https://www.ncbi.nlm.nih.gov/pubmed/30658231
http://dx.doi.org/10.1016/j.jelekin.2019.01.001
work_keys_str_mv AT hughestom thevalueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT jonesrichardk thevalueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT starbuckchelsea thevalueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT sergeantjamiec thevalueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT callaghanmichaelj thevalueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT hughestom valueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT jonesrichardk valueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT starbuckchelsea valueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT sergeantjamiec valueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem
AT callaghanmichaelj valueoftibialmountedinertialmeasurementunitstoquantifyrunningkineticsinelitefootballsoccerplayersareliabilityandagreementstudyusingaresearchorientatedandaclinicallyorientatedsystem