Cargando…

Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system

BACKGROUND: Preoperative planning of total knee arthroplasty is usually performed using knee-centred computed tomography (CT) data sets. The disadvantage of these data sets is having no account of the biomechanical axis of the lower extremity, known as Mikulicz line. It aligns the femoral head to th...

Descripción completa

Detalles Bibliográficos
Autores principales: Scherer, Thomas P., Hoechel, Sebastian, Müller-Gerbl, Magdalena, Nowakowski, Andrej M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Chinese Speaking Orthopaedic Society 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6350020/
https://www.ncbi.nlm.nih.gov/pubmed/30723684
http://dx.doi.org/10.1016/j.jot.2018.07.005
_version_ 1783390370737946624
author Scherer, Thomas P.
Hoechel, Sebastian
Müller-Gerbl, Magdalena
Nowakowski, Andrej M.
author_facet Scherer, Thomas P.
Hoechel, Sebastian
Müller-Gerbl, Magdalena
Nowakowski, Andrej M.
author_sort Scherer, Thomas P.
collection PubMed
description BACKGROUND: Preoperative planning of total knee arthroplasty is usually performed using knee-centred computed tomography (CT) data sets. The disadvantage of these data sets is having no account of the biomechanical axis of the lower extremity, known as Mikulicz line. It aligns the femoral head to the middle of the talocrural joint. For optimal prosthesis arrangement, the knee CT data set must therefore be brought in congruency with this line of loading to achieve the best results and eliminate rotational malalignments. This study aims to establish a relation between the knee-centred clinical coordinate system (CCS) and a biomechanical coordinate system (BCS) based on the Mikulicz line. METHODS: CT data sets of 45 lower extremities were evaluated. Using VG Studio Max, a visualisation and measurement software program; each CT data set was aligned according to the CCS and BCS. After superimposing both the aligned data sets, the deviations of both coordinate systems in all three planes were measured with the centre of the knee defined as the origin. RESULTS: For the coronal plane, the CCS was demonstrated to be 2.54° in adduction compared to the BCS [standard deviation (SD) = 1.8°]. In sagittal view, the CCS was demonstrated to be 0.3° retroversed (SD = 3.27°). Finally, the deviation in the axial plane showed an outward rotation of 3.39° (SD = 1.99°). The alignment as well as the measurements demonstrated high intraobserver and interobserver reproducibility. CONCLUSION: Both coordinate systems can be established in knee-centred CT data sets in a reproducible manner. Clearly, the CCS differs significantly from the BCS describing the biomechanical axis, but mathematical-based adaptations and corrections can be performed. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The findings of this study allow a mathematical conversion of a knee CT to the biomechanical axis of the leg.
format Online
Article
Text
id pubmed-6350020
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Chinese Speaking Orthopaedic Society
record_format MEDLINE/PubMed
spelling pubmed-63500202019-02-05 Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system Scherer, Thomas P. Hoechel, Sebastian Müller-Gerbl, Magdalena Nowakowski, Andrej M. J Orthop Translat Original Article BACKGROUND: Preoperative planning of total knee arthroplasty is usually performed using knee-centred computed tomography (CT) data sets. The disadvantage of these data sets is having no account of the biomechanical axis of the lower extremity, known as Mikulicz line. It aligns the femoral head to the middle of the talocrural joint. For optimal prosthesis arrangement, the knee CT data set must therefore be brought in congruency with this line of loading to achieve the best results and eliminate rotational malalignments. This study aims to establish a relation between the knee-centred clinical coordinate system (CCS) and a biomechanical coordinate system (BCS) based on the Mikulicz line. METHODS: CT data sets of 45 lower extremities were evaluated. Using VG Studio Max, a visualisation and measurement software program; each CT data set was aligned according to the CCS and BCS. After superimposing both the aligned data sets, the deviations of both coordinate systems in all three planes were measured with the centre of the knee defined as the origin. RESULTS: For the coronal plane, the CCS was demonstrated to be 2.54° in adduction compared to the BCS [standard deviation (SD) = 1.8°]. In sagittal view, the CCS was demonstrated to be 0.3° retroversed (SD = 3.27°). Finally, the deviation in the axial plane showed an outward rotation of 3.39° (SD = 1.99°). The alignment as well as the measurements demonstrated high intraobserver and interobserver reproducibility. CONCLUSION: Both coordinate systems can be established in knee-centred CT data sets in a reproducible manner. Clearly, the CCS differs significantly from the BCS describing the biomechanical axis, but mathematical-based adaptations and corrections can be performed. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The findings of this study allow a mathematical conversion of a knee CT to the biomechanical axis of the leg. Chinese Speaking Orthopaedic Society 2018-08-09 /pmc/articles/PMC6350020/ /pubmed/30723684 http://dx.doi.org/10.1016/j.jot.2018.07.005 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Scherer, Thomas P.
Hoechel, Sebastian
Müller-Gerbl, Magdalena
Nowakowski, Andrej M.
Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system
title Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system
title_full Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system
title_fullStr Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system
title_full_unstemmed Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system
title_short Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system
title_sort comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6350020/
https://www.ncbi.nlm.nih.gov/pubmed/30723684
http://dx.doi.org/10.1016/j.jot.2018.07.005
work_keys_str_mv AT schererthomasp comparisonofkneejointorientationinclinicallyversusbiomechanicallyalignedcomputedtomographycoordinatesystem
AT hoechelsebastian comparisonofkneejointorientationinclinicallyversusbiomechanicallyalignedcomputedtomographycoordinatesystem
AT mullergerblmagdalena comparisonofkneejointorientationinclinicallyversusbiomechanicallyalignedcomputedtomographycoordinatesystem
AT nowakowskiandrejm comparisonofkneejointorientationinclinicallyversusbiomechanicallyalignedcomputedtomographycoordinatesystem