Cargando…

A Smartphone-Based Rapid Telemonitoring System for Ebola and Marburg Disease Surveillance

[Image: see text] We have developed a digital and multiplexed platform for the rapid detection and telemonitoring of infections caused by Ebola and Marburg filoviruses. The system includes a flow cell assay cartridge that captures specific antibodies with microarrayed recombinant antigens from all s...

Descripción completa

Detalles Bibliográficos
Autores principales: Natesan, Mohan, Wu, Sz-Wei, Chen, Chieh-I, Jensen, Stig M. R., Karlovac, Neven, Dyas, Beverly K., Mudanyali, Onur, Ulrich, Robert G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6350200/
https://www.ncbi.nlm.nih.gov/pubmed/30525467
http://dx.doi.org/10.1021/acssensors.8b00842
_version_ 1783390406156746752
author Natesan, Mohan
Wu, Sz-Wei
Chen, Chieh-I
Jensen, Stig M. R.
Karlovac, Neven
Dyas, Beverly K.
Mudanyali, Onur
Ulrich, Robert G.
author_facet Natesan, Mohan
Wu, Sz-Wei
Chen, Chieh-I
Jensen, Stig M. R.
Karlovac, Neven
Dyas, Beverly K.
Mudanyali, Onur
Ulrich, Robert G.
author_sort Natesan, Mohan
collection PubMed
description [Image: see text] We have developed a digital and multiplexed platform for the rapid detection and telemonitoring of infections caused by Ebola and Marburg filoviruses. The system includes a flow cell assay cartridge that captures specific antibodies with microarrayed recombinant antigens from all six species of filovirus, and a smartphone fluorescent reader for high-performance interpretation of test results. Multiplexed viral proteins, which are expandable to include greater numbers of probes, were incorporated to obtain highest confidence results by cross-correlation, and a custom smartphone application was developed for data analysis, interpretation, and communication. The smartphone reader utilizes an opto-electro-mechanical hardware attachment that snaps at the back of a Motorola smartphone and provides a user interface to manage the operation, acquire test results, and communicate with cloud service. The application controls the hardware attachment to turn on LEDs and digitally record the optically enhanced images. Assay processing time is approximately 20 min for microliter amounts of blood, and test results are digitally processed and displayed within 15 s. Furthermore, a secure cloud service was developed for the telemonitoring of test results generated by the smartphone readers in the field. Assay system results were tested with sera from nonhuman primates that received a live attenuated EBOV vaccine. This integrated system will provide a rapid, reliable, and digital solution to prevent the rapid overwhelming of medical systems and resources during EVD or MVD outbreaks. Further, this disease-monitoring system will be useful in resource-limited countries where there is a need for dispersed laboratory analysis of recent or active infections.
format Online
Article
Text
id pubmed-6350200
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-63502002019-01-31 A Smartphone-Based Rapid Telemonitoring System for Ebola and Marburg Disease Surveillance Natesan, Mohan Wu, Sz-Wei Chen, Chieh-I Jensen, Stig M. R. Karlovac, Neven Dyas, Beverly K. Mudanyali, Onur Ulrich, Robert G. ACS Sens [Image: see text] We have developed a digital and multiplexed platform for the rapid detection and telemonitoring of infections caused by Ebola and Marburg filoviruses. The system includes a flow cell assay cartridge that captures specific antibodies with microarrayed recombinant antigens from all six species of filovirus, and a smartphone fluorescent reader for high-performance interpretation of test results. Multiplexed viral proteins, which are expandable to include greater numbers of probes, were incorporated to obtain highest confidence results by cross-correlation, and a custom smartphone application was developed for data analysis, interpretation, and communication. The smartphone reader utilizes an opto-electro-mechanical hardware attachment that snaps at the back of a Motorola smartphone and provides a user interface to manage the operation, acquire test results, and communicate with cloud service. The application controls the hardware attachment to turn on LEDs and digitally record the optically enhanced images. Assay processing time is approximately 20 min for microliter amounts of blood, and test results are digitally processed and displayed within 15 s. Furthermore, a secure cloud service was developed for the telemonitoring of test results generated by the smartphone readers in the field. Assay system results were tested with sera from nonhuman primates that received a live attenuated EBOV vaccine. This integrated system will provide a rapid, reliable, and digital solution to prevent the rapid overwhelming of medical systems and resources during EVD or MVD outbreaks. Further, this disease-monitoring system will be useful in resource-limited countries where there is a need for dispersed laboratory analysis of recent or active infections. American Chemical Society 2018-12-07 2019-01-25 /pmc/articles/PMC6350200/ /pubmed/30525467 http://dx.doi.org/10.1021/acssensors.8b00842 Text en Copyright © 2018 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Natesan, Mohan
Wu, Sz-Wei
Chen, Chieh-I
Jensen, Stig M. R.
Karlovac, Neven
Dyas, Beverly K.
Mudanyali, Onur
Ulrich, Robert G.
A Smartphone-Based Rapid Telemonitoring System for Ebola and Marburg Disease Surveillance
title A Smartphone-Based Rapid Telemonitoring System for Ebola and Marburg Disease Surveillance
title_full A Smartphone-Based Rapid Telemonitoring System for Ebola and Marburg Disease Surveillance
title_fullStr A Smartphone-Based Rapid Telemonitoring System for Ebola and Marburg Disease Surveillance
title_full_unstemmed A Smartphone-Based Rapid Telemonitoring System for Ebola and Marburg Disease Surveillance
title_short A Smartphone-Based Rapid Telemonitoring System for Ebola and Marburg Disease Surveillance
title_sort smartphone-based rapid telemonitoring system for ebola and marburg disease surveillance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6350200/
https://www.ncbi.nlm.nih.gov/pubmed/30525467
http://dx.doi.org/10.1021/acssensors.8b00842
work_keys_str_mv AT natesanmohan asmartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT wuszwei asmartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT chenchiehi asmartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT jensenstigmr asmartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT karlovacneven asmartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT dyasbeverlyk asmartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT mudanyalionur asmartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT ulrichrobertg asmartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT natesanmohan smartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT wuszwei smartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT chenchiehi smartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT jensenstigmr smartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT karlovacneven smartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT dyasbeverlyk smartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT mudanyalionur smartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance
AT ulrichrobertg smartphonebasedrapidtelemonitoringsystemforebolaandmarburgdiseasesurveillance