Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems

Purpose A new dual-layer multi-leaf collimator (MLC) system with several improved characteristics was introduced with the Varian Halcyon™ treatment platform. This study evaluated this new MLC’s impact on head and neck plan quality and delivery efficiency. Methods Nine patients were retrospectively s...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Taoran, Scheuermann, Ryan, Lin, Alexander, Teo, Boon-Keng Kevin, Zou, Wei, Swisher-McClure, Samuel, Alonso-Basanta, Michelle, Lukens, John N, Fotouhi Ghiam, Alireza, Kennedy, Chris, Kim, Michele M, Mihailidis, Dimitris, Metz, James M, Dong, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6351111/
https://www.ncbi.nlm.nih.gov/pubmed/30723647
http://dx.doi.org/10.7759/cureus.3648
_version_ 1783390539234672640
author Li, Taoran
Scheuermann, Ryan
Lin, Alexander
Teo, Boon-Keng Kevin
Zou, Wei
Swisher-McClure, Samuel
Alonso-Basanta, Michelle
Lukens, John N
Fotouhi Ghiam, Alireza
Kennedy, Chris
Kim, Michele M
Mihailidis, Dimitris
Metz, James M
Dong, Lei
author_facet Li, Taoran
Scheuermann, Ryan
Lin, Alexander
Teo, Boon-Keng Kevin
Zou, Wei
Swisher-McClure, Samuel
Alonso-Basanta, Michelle
Lukens, John N
Fotouhi Ghiam, Alireza
Kennedy, Chris
Kim, Michele M
Mihailidis, Dimitris
Metz, James M
Dong, Lei
author_sort Li, Taoran
collection PubMed
description Purpose A new dual-layer multi-leaf collimator (MLC) system with several improved characteristics was introduced with the Varian Halcyon™ treatment platform. This study evaluated this new MLC’s impact on head and neck plan quality and delivery efficiency. Methods Nine patients were retrospectively studied with Institutional Review Board (IRB) approval. To compare plan quality between the Halcyon dual-layer MLC and Truebeam® MLC, all patients were replanned with the same prescription and target coverage following the institutional clinical protocol for both platforms and using both intensity modulated radiation therapy (IMRT) or volumetrically modulated arc therapy (VMAT) techniques. Organs-at-risk (OAR) dose-volume histogram (DVH) statistics were compared along with total plan monitor units (MU). To evaluate delivery efficiency, actual beam-on time for five patients’ plans were recorded and compared. To evaluate the impact of MLC performance parameters on plan quality, virtual MLC models were generated by matching Truebeam MLC’s parameters to those of the Halcyon dual-layer MLC both individually and combined. OAR doses were then compared between these virtual MLCs, the Truebeam MLC, and the actual Halcyon MLC. Results Overall the Halcyon dual-layer MLC provided similar plan quality compared to Truebeam MLC for VMAT plans, and improved sparing for majority of the OARs when using IMRT. Paired comparison showed median dose differences in mean doses to the parotids, cochlea, esophagus, and larynx ranged from -0.83 Gy to 0.37 Gy for VMAT, and from -4.79 Gy to -0.04 Gy for IMRT, with negative values indicating improved performance by Halcyon. Despite a slight increase in plan MU, the Halcyon reduced the total beam-on time by 42.8 ± 8.5%. Virtual MLC simulations demonstrated that matching MLC transmission accounted for nearly half of the total dose difference between Halcyon and Truebeam IMRT plans. Conclusion When compared to the Truebeam, the Halcyon’s dual-layer MLC achieved similar plan quality using VMAT, and improved OAR sparing using IMRT, while providing nearly twice as fast treatment delivery. Reduction in MLC transmission is the dominating factor contributing to dosimetric differences in OAR sparing.
format Online
Article
Text
id pubmed-6351111
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-63511112019-02-05 Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems Li, Taoran Scheuermann, Ryan Lin, Alexander Teo, Boon-Keng Kevin Zou, Wei Swisher-McClure, Samuel Alonso-Basanta, Michelle Lukens, John N Fotouhi Ghiam, Alireza Kennedy, Chris Kim, Michele M Mihailidis, Dimitris Metz, James M Dong, Lei Cureus Medical Physics Purpose A new dual-layer multi-leaf collimator (MLC) system with several improved characteristics was introduced with the Varian Halcyon™ treatment platform. This study evaluated this new MLC’s impact on head and neck plan quality and delivery efficiency. Methods Nine patients were retrospectively studied with Institutional Review Board (IRB) approval. To compare plan quality between the Halcyon dual-layer MLC and Truebeam® MLC, all patients were replanned with the same prescription and target coverage following the institutional clinical protocol for both platforms and using both intensity modulated radiation therapy (IMRT) or volumetrically modulated arc therapy (VMAT) techniques. Organs-at-risk (OAR) dose-volume histogram (DVH) statistics were compared along with total plan monitor units (MU). To evaluate delivery efficiency, actual beam-on time for five patients’ plans were recorded and compared. To evaluate the impact of MLC performance parameters on plan quality, virtual MLC models were generated by matching Truebeam MLC’s parameters to those of the Halcyon dual-layer MLC both individually and combined. OAR doses were then compared between these virtual MLCs, the Truebeam MLC, and the actual Halcyon MLC. Results Overall the Halcyon dual-layer MLC provided similar plan quality compared to Truebeam MLC for VMAT plans, and improved sparing for majority of the OARs when using IMRT. Paired comparison showed median dose differences in mean doses to the parotids, cochlea, esophagus, and larynx ranged from -0.83 Gy to 0.37 Gy for VMAT, and from -4.79 Gy to -0.04 Gy for IMRT, with negative values indicating improved performance by Halcyon. Despite a slight increase in plan MU, the Halcyon reduced the total beam-on time by 42.8 ± 8.5%. Virtual MLC simulations demonstrated that matching MLC transmission accounted for nearly half of the total dose difference between Halcyon and Truebeam IMRT plans. Conclusion When compared to the Truebeam, the Halcyon’s dual-layer MLC achieved similar plan quality using VMAT, and improved OAR sparing using IMRT, while providing nearly twice as fast treatment delivery. Reduction in MLC transmission is the dominating factor contributing to dosimetric differences in OAR sparing. Cureus 2018-11-28 /pmc/articles/PMC6351111/ /pubmed/30723647 http://dx.doi.org/10.7759/cureus.3648 Text en Copyright © 2018, Li et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Physics
Li, Taoran
Scheuermann, Ryan
Lin, Alexander
Teo, Boon-Keng Kevin
Zou, Wei
Swisher-McClure, Samuel
Alonso-Basanta, Michelle
Lukens, John N
Fotouhi Ghiam, Alireza
Kennedy, Chris
Kim, Michele M
Mihailidis, Dimitris
Metz, James M
Dong, Lei
Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems
title Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems
title_full Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems
title_fullStr Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems
title_full_unstemmed Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems
title_short Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems
title_sort impact of multi-leaf collimator parameters on head and neck plan quality and delivery: a comparison between halcyon™ and truebeam® treatment delivery systems
topic Medical Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6351111/
https://www.ncbi.nlm.nih.gov/pubmed/30723647
http://dx.doi.org/10.7759/cureus.3648
work_keys_str_mv AT litaoran impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT scheuermannryan impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT linalexander impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT teoboonkengkevin impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT zouwei impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT swishermccluresamuel impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT alonsobasantamichelle impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT lukensjohnn impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT fotouhighiamalireza impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT kennedychris impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT kimmichelem impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT mihailidisdimitris impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT metzjamesm impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems
AT donglei impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems