Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems
Purpose A new dual-layer multi-leaf collimator (MLC) system with several improved characteristics was introduced with the Varian Halcyon™ treatment platform. This study evaluated this new MLC’s impact on head and neck plan quality and delivery efficiency. Methods Nine patients were retrospectively s...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6351111/ https://www.ncbi.nlm.nih.gov/pubmed/30723647 http://dx.doi.org/10.7759/cureus.3648 |
_version_ | 1783390539234672640 |
---|---|
author | Li, Taoran Scheuermann, Ryan Lin, Alexander Teo, Boon-Keng Kevin Zou, Wei Swisher-McClure, Samuel Alonso-Basanta, Michelle Lukens, John N Fotouhi Ghiam, Alireza Kennedy, Chris Kim, Michele M Mihailidis, Dimitris Metz, James M Dong, Lei |
author_facet | Li, Taoran Scheuermann, Ryan Lin, Alexander Teo, Boon-Keng Kevin Zou, Wei Swisher-McClure, Samuel Alonso-Basanta, Michelle Lukens, John N Fotouhi Ghiam, Alireza Kennedy, Chris Kim, Michele M Mihailidis, Dimitris Metz, James M Dong, Lei |
author_sort | Li, Taoran |
collection | PubMed |
description | Purpose A new dual-layer multi-leaf collimator (MLC) system with several improved characteristics was introduced with the Varian Halcyon™ treatment platform. This study evaluated this new MLC’s impact on head and neck plan quality and delivery efficiency. Methods Nine patients were retrospectively studied with Institutional Review Board (IRB) approval. To compare plan quality between the Halcyon dual-layer MLC and Truebeam® MLC, all patients were replanned with the same prescription and target coverage following the institutional clinical protocol for both platforms and using both intensity modulated radiation therapy (IMRT) or volumetrically modulated arc therapy (VMAT) techniques. Organs-at-risk (OAR) dose-volume histogram (DVH) statistics were compared along with total plan monitor units (MU). To evaluate delivery efficiency, actual beam-on time for five patients’ plans were recorded and compared. To evaluate the impact of MLC performance parameters on plan quality, virtual MLC models were generated by matching Truebeam MLC’s parameters to those of the Halcyon dual-layer MLC both individually and combined. OAR doses were then compared between these virtual MLCs, the Truebeam MLC, and the actual Halcyon MLC. Results Overall the Halcyon dual-layer MLC provided similar plan quality compared to Truebeam MLC for VMAT plans, and improved sparing for majority of the OARs when using IMRT. Paired comparison showed median dose differences in mean doses to the parotids, cochlea, esophagus, and larynx ranged from -0.83 Gy to 0.37 Gy for VMAT, and from -4.79 Gy to -0.04 Gy for IMRT, with negative values indicating improved performance by Halcyon. Despite a slight increase in plan MU, the Halcyon reduced the total beam-on time by 42.8 ± 8.5%. Virtual MLC simulations demonstrated that matching MLC transmission accounted for nearly half of the total dose difference between Halcyon and Truebeam IMRT plans. Conclusion When compared to the Truebeam, the Halcyon’s dual-layer MLC achieved similar plan quality using VMAT, and improved OAR sparing using IMRT, while providing nearly twice as fast treatment delivery. Reduction in MLC transmission is the dominating factor contributing to dosimetric differences in OAR sparing. |
format | Online Article Text |
id | pubmed-6351111 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-63511112019-02-05 Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems Li, Taoran Scheuermann, Ryan Lin, Alexander Teo, Boon-Keng Kevin Zou, Wei Swisher-McClure, Samuel Alonso-Basanta, Michelle Lukens, John N Fotouhi Ghiam, Alireza Kennedy, Chris Kim, Michele M Mihailidis, Dimitris Metz, James M Dong, Lei Cureus Medical Physics Purpose A new dual-layer multi-leaf collimator (MLC) system with several improved characteristics was introduced with the Varian Halcyon™ treatment platform. This study evaluated this new MLC’s impact on head and neck plan quality and delivery efficiency. Methods Nine patients were retrospectively studied with Institutional Review Board (IRB) approval. To compare plan quality between the Halcyon dual-layer MLC and Truebeam® MLC, all patients were replanned with the same prescription and target coverage following the institutional clinical protocol for both platforms and using both intensity modulated radiation therapy (IMRT) or volumetrically modulated arc therapy (VMAT) techniques. Organs-at-risk (OAR) dose-volume histogram (DVH) statistics were compared along with total plan monitor units (MU). To evaluate delivery efficiency, actual beam-on time for five patients’ plans were recorded and compared. To evaluate the impact of MLC performance parameters on plan quality, virtual MLC models were generated by matching Truebeam MLC’s parameters to those of the Halcyon dual-layer MLC both individually and combined. OAR doses were then compared between these virtual MLCs, the Truebeam MLC, and the actual Halcyon MLC. Results Overall the Halcyon dual-layer MLC provided similar plan quality compared to Truebeam MLC for VMAT plans, and improved sparing for majority of the OARs when using IMRT. Paired comparison showed median dose differences in mean doses to the parotids, cochlea, esophagus, and larynx ranged from -0.83 Gy to 0.37 Gy for VMAT, and from -4.79 Gy to -0.04 Gy for IMRT, with negative values indicating improved performance by Halcyon. Despite a slight increase in plan MU, the Halcyon reduced the total beam-on time by 42.8 ± 8.5%. Virtual MLC simulations demonstrated that matching MLC transmission accounted for nearly half of the total dose difference between Halcyon and Truebeam IMRT plans. Conclusion When compared to the Truebeam, the Halcyon’s dual-layer MLC achieved similar plan quality using VMAT, and improved OAR sparing using IMRT, while providing nearly twice as fast treatment delivery. Reduction in MLC transmission is the dominating factor contributing to dosimetric differences in OAR sparing. Cureus 2018-11-28 /pmc/articles/PMC6351111/ /pubmed/30723647 http://dx.doi.org/10.7759/cureus.3648 Text en Copyright © 2018, Li et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Medical Physics Li, Taoran Scheuermann, Ryan Lin, Alexander Teo, Boon-Keng Kevin Zou, Wei Swisher-McClure, Samuel Alonso-Basanta, Michelle Lukens, John N Fotouhi Ghiam, Alireza Kennedy, Chris Kim, Michele M Mihailidis, Dimitris Metz, James M Dong, Lei Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems |
title | Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems |
title_full | Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems |
title_fullStr | Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems |
title_full_unstemmed | Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems |
title_short | Impact of Multi-leaf Collimator Parameters on Head and Neck Plan Quality and Delivery: A Comparison between Halcyon™ and Truebeam® Treatment Delivery Systems |
title_sort | impact of multi-leaf collimator parameters on head and neck plan quality and delivery: a comparison between halcyon™ and truebeam® treatment delivery systems |
topic | Medical Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6351111/ https://www.ncbi.nlm.nih.gov/pubmed/30723647 http://dx.doi.org/10.7759/cureus.3648 |
work_keys_str_mv | AT litaoran impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT scheuermannryan impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT linalexander impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT teoboonkengkevin impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT zouwei impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT swishermccluresamuel impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT alonsobasantamichelle impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT lukensjohnn impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT fotouhighiamalireza impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT kennedychris impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT kimmichelem impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT mihailidisdimitris impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT metzjamesm impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems AT donglei impactofmultileafcollimatorparametersonheadandneckplanqualityanddeliveryacomparisonbetweenhalcyonandtruebeamtreatmentdeliverysystems |