Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

OBJECTIVE(S): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size. METHODS: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologic...

Descripción completa

Detalles Bibliográficos
Autores principales: Yano, Fuzuki, Itoh, Masatoshi, Hirakawa, Hisashi, Yamamoto, Seiichi, Yoshikawa, Akira, Hatazawa, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mashhad University of Medical Sciences 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352056/
https://www.ncbi.nlm.nih.gov/pubmed/30705907
http://dx.doi.org/10.22038/AOJNMB.2018.31101.1213
Descripción
Sumario:OBJECTIVE(S): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size. METHODS: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors was 54 (mean size: 11±5.1 mm, range: 4-20 mm). The diagnostic accuracy of PEM alone, PET/CT alone, and combined PET/CT and PEM was evaluated by two nuclear medicine physicians based on visual inspection. The two groups (i.e., tumors of ≤ 10 mm and > 10-20 mm) were compared in terms of the diagnostic capability of the three modalities (PEM alone, PET/CT alone, and PET/CT+PEM). RESULTS: The sensitivities of PEM alone, PET/CT alone, and combined PET/CT and PEM were 72%, 60%, and 76%, respectively. The specificities of these tests were 98%, 100%, and 98%, respectively. Furthermore, the accuracies of these diagnostic modalities were 85%, 79%, and 87%, respectively. The combined PET/CT and PEM showed significantly higher sensitivity and accuracy than PET/CT alone (P=0.005 and P=0.02, respectively). In addition, PEM demonstrated a significantly higher sensitivity than PET/CT in the ≤ 10 mm group (P=0.03); however, no difference was observed between the two modalities in the > 10 mm group in terms of sensitivity. CONCLUSION: (18)F-fluorodeoxyglucose PET had limited capability for the detection of small breast cancers of < 10 mm. Combined PET/CT and PEM showed higher sensitivity and accuracy, compared to PET/CT alone.