Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

OBJECTIVE(S): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size. METHODS: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologic...

Descripción completa

Detalles Bibliográficos
Autores principales: Yano, Fuzuki, Itoh, Masatoshi, Hirakawa, Hisashi, Yamamoto, Seiichi, Yoshikawa, Akira, Hatazawa, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mashhad University of Medical Sciences 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352056/
https://www.ncbi.nlm.nih.gov/pubmed/30705907
http://dx.doi.org/10.22038/AOJNMB.2018.31101.1213
_version_ 1783390734048559104
author Yano, Fuzuki
Itoh, Masatoshi
Hirakawa, Hisashi
Yamamoto, Seiichi
Yoshikawa, Akira
Hatazawa, Jun
author_facet Yano, Fuzuki
Itoh, Masatoshi
Hirakawa, Hisashi
Yamamoto, Seiichi
Yoshikawa, Akira
Hatazawa, Jun
author_sort Yano, Fuzuki
collection PubMed
description OBJECTIVE(S): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size. METHODS: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors was 54 (mean size: 11±5.1 mm, range: 4-20 mm). The diagnostic accuracy of PEM alone, PET/CT alone, and combined PET/CT and PEM was evaluated by two nuclear medicine physicians based on visual inspection. The two groups (i.e., tumors of ≤ 10 mm and > 10-20 mm) were compared in terms of the diagnostic capability of the three modalities (PEM alone, PET/CT alone, and PET/CT+PEM). RESULTS: The sensitivities of PEM alone, PET/CT alone, and combined PET/CT and PEM were 72%, 60%, and 76%, respectively. The specificities of these tests were 98%, 100%, and 98%, respectively. Furthermore, the accuracies of these diagnostic modalities were 85%, 79%, and 87%, respectively. The combined PET/CT and PEM showed significantly higher sensitivity and accuracy than PET/CT alone (P=0.005 and P=0.02, respectively). In addition, PEM demonstrated a significantly higher sensitivity than PET/CT in the ≤ 10 mm group (P=0.03); however, no difference was observed between the two modalities in the > 10 mm group in terms of sensitivity. CONCLUSION: (18)F-fluorodeoxyglucose PET had limited capability for the detection of small breast cancers of < 10 mm. Combined PET/CT and PEM showed higher sensitivity and accuracy, compared to PET/CT alone.
format Online
Article
Text
id pubmed-6352056
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Mashhad University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-63520562019-01-31 Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size Yano, Fuzuki Itoh, Masatoshi Hirakawa, Hisashi Yamamoto, Seiichi Yoshikawa, Akira Hatazawa, Jun Asia Ocean J Nucl Med Biol Original Article OBJECTIVE(S): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size. METHODS: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors was 54 (mean size: 11±5.1 mm, range: 4-20 mm). The diagnostic accuracy of PEM alone, PET/CT alone, and combined PET/CT and PEM was evaluated by two nuclear medicine physicians based on visual inspection. The two groups (i.e., tumors of ≤ 10 mm and > 10-20 mm) were compared in terms of the diagnostic capability of the three modalities (PEM alone, PET/CT alone, and PET/CT+PEM). RESULTS: The sensitivities of PEM alone, PET/CT alone, and combined PET/CT and PEM were 72%, 60%, and 76%, respectively. The specificities of these tests were 98%, 100%, and 98%, respectively. Furthermore, the accuracies of these diagnostic modalities were 85%, 79%, and 87%, respectively. The combined PET/CT and PEM showed significantly higher sensitivity and accuracy than PET/CT alone (P=0.005 and P=0.02, respectively). In addition, PEM demonstrated a significantly higher sensitivity than PET/CT in the ≤ 10 mm group (P=0.03); however, no difference was observed between the two modalities in the > 10 mm group in terms of sensitivity. CONCLUSION: (18)F-fluorodeoxyglucose PET had limited capability for the detection of small breast cancers of < 10 mm. Combined PET/CT and PEM showed higher sensitivity and accuracy, compared to PET/CT alone. Mashhad University of Medical Sciences 2019 /pmc/articles/PMC6352056/ /pubmed/30705907 http://dx.doi.org/10.22038/AOJNMB.2018.31101.1213 Text en © 2019 mums.ac.ir This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yano, Fuzuki
Itoh, Masatoshi
Hirakawa, Hisashi
Yamamoto, Seiichi
Yoshikawa, Akira
Hatazawa, Jun
Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
title Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
title_full Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
title_fullStr Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
title_full_unstemmed Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
title_short Diagnostic Accuracy of Positron Emission Mammography with (18)F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
title_sort diagnostic accuracy of positron emission mammography with (18)f-fluorodeoxyglucose in breast cancer tumor of less than 20 mm in size
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352056/
https://www.ncbi.nlm.nih.gov/pubmed/30705907
http://dx.doi.org/10.22038/AOJNMB.2018.31101.1213
work_keys_str_mv AT yanofuzuki diagnosticaccuracyofpositronemissionmammographywith18ffluorodeoxyglucoseinbreastcancertumoroflessthan20mminsize
AT itohmasatoshi diagnosticaccuracyofpositronemissionmammographywith18ffluorodeoxyglucoseinbreastcancertumoroflessthan20mminsize
AT hirakawahisashi diagnosticaccuracyofpositronemissionmammographywith18ffluorodeoxyglucoseinbreastcancertumoroflessthan20mminsize
AT yamamotoseiichi diagnosticaccuracyofpositronemissionmammographywith18ffluorodeoxyglucoseinbreastcancertumoroflessthan20mminsize
AT yoshikawaakira diagnosticaccuracyofpositronemissionmammographywith18ffluorodeoxyglucoseinbreastcancertumoroflessthan20mminsize
AT hatazawajun diagnosticaccuracyofpositronemissionmammographywith18ffluorodeoxyglucoseinbreastcancertumoroflessthan20mminsize