Cargando…
Safety of Permanent Pacemaker Implantation: A Prospective Study
Although pacemaker implantation is considered to be low risk, it is not exempt from complications and technical failures during the procedure, both in the short and long term, and the complications that such patients may present remain unknown. The aim has been to analyze the complication rates asso...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352172/ https://www.ncbi.nlm.nih.gov/pubmed/30609668 http://dx.doi.org/10.3390/jcm8010035 |
_version_ | 1783390768772153344 |
---|---|
author | Carrión-Camacho, Mª Reyes Marín-León, Ignacio Molina-Doñoro, José Manuel González-López, José Rafael |
author_facet | Carrión-Camacho, Mª Reyes Marín-León, Ignacio Molina-Doñoro, José Manuel González-López, José Rafael |
author_sort | Carrión-Camacho, Mª Reyes |
collection | PubMed |
description | Although pacemaker implantation is considered to be low risk, it is not exempt from complications and technical failures during the procedure, both in the short and long term, and the complications that such patients may present remain unknown. The aim has been to analyze the complication rates associated with permanent pacing and to identify if these differ between patients with or without previous antithrombotic therapy. We used a prospective, single center, observational study of 310 adult patients with indications of permanent pacing. They were hospitalized from 1 January to 31 December 2014 and followed up for 6 months after the pacemaker implant. The participants were distributed into two groups according to the antithrombotic therapy prior to the implant. The most frequent major complications were pneumothorax (3.87%) and lead dislodgement (8.39%), while superficial phlebitis (12.90%) and uncomplicated hematomas (22.58%) were presented as the most recurrent minor complications. Hematomas were the most frequent minor complication in the antithrombotic therapy cohort, and shoulder pain was reported as the most recurrent minor complication in the non-exposed group. Finding out about complications in pacemaker implants enables a complete view of the process, and hence the prioritization of actions aimed at improving safety and reducing associated risks. |
format | Online Article Text |
id | pubmed-6352172 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63521722019-02-01 Safety of Permanent Pacemaker Implantation: A Prospective Study Carrión-Camacho, Mª Reyes Marín-León, Ignacio Molina-Doñoro, José Manuel González-López, José Rafael J Clin Med Article Although pacemaker implantation is considered to be low risk, it is not exempt from complications and technical failures during the procedure, both in the short and long term, and the complications that such patients may present remain unknown. The aim has been to analyze the complication rates associated with permanent pacing and to identify if these differ between patients with or without previous antithrombotic therapy. We used a prospective, single center, observational study of 310 adult patients with indications of permanent pacing. They were hospitalized from 1 January to 31 December 2014 and followed up for 6 months after the pacemaker implant. The participants were distributed into two groups according to the antithrombotic therapy prior to the implant. The most frequent major complications were pneumothorax (3.87%) and lead dislodgement (8.39%), while superficial phlebitis (12.90%) and uncomplicated hematomas (22.58%) were presented as the most recurrent minor complications. Hematomas were the most frequent minor complication in the antithrombotic therapy cohort, and shoulder pain was reported as the most recurrent minor complication in the non-exposed group. Finding out about complications in pacemaker implants enables a complete view of the process, and hence the prioritization of actions aimed at improving safety and reducing associated risks. MDPI 2019-01-01 /pmc/articles/PMC6352172/ /pubmed/30609668 http://dx.doi.org/10.3390/jcm8010035 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Carrión-Camacho, Mª Reyes Marín-León, Ignacio Molina-Doñoro, José Manuel González-López, José Rafael Safety of Permanent Pacemaker Implantation: A Prospective Study |
title | Safety of Permanent Pacemaker Implantation: A Prospective Study |
title_full | Safety of Permanent Pacemaker Implantation: A Prospective Study |
title_fullStr | Safety of Permanent Pacemaker Implantation: A Prospective Study |
title_full_unstemmed | Safety of Permanent Pacemaker Implantation: A Prospective Study |
title_short | Safety of Permanent Pacemaker Implantation: A Prospective Study |
title_sort | safety of permanent pacemaker implantation: a prospective study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352172/ https://www.ncbi.nlm.nih.gov/pubmed/30609668 http://dx.doi.org/10.3390/jcm8010035 |
work_keys_str_mv | AT carrioncamachomareyes safetyofpermanentpacemakerimplantationaprospectivestudy AT marinleonignacio safetyofpermanentpacemakerimplantationaprospectivestudy AT molinadonorojosemanuel safetyofpermanentpacemakerimplantationaprospectivestudy AT gonzalezlopezjoserafael safetyofpermanentpacemakerimplantationaprospectivestudy |