Cargando…
Intermittent Use of Portable NIV Increases Exercise Tolerance in COPD: A Randomised, Cross-Over Trial
During exercise, non-invasive ventilation (NIV) prolongs endurance in chronic obstructive pulmonary disease (COPD), but routine use is impractical. The VitaBreath device provides portable NIV (pNIV); however, it can only be used during recovery. We assessed the effect of pNIV compared to pursed lip...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352193/ https://www.ncbi.nlm.nih.gov/pubmed/30650617 http://dx.doi.org/10.3390/jcm8010094 |
_version_ | 1783390774394617856 |
---|---|
author | Vogiatzis, Ioannis Chynkiamis, Nikolaos Armstrong, Matthew Lane, Nicholas D. Hartley, Tom Gray, William K. Bourke, Stephen C. |
author_facet | Vogiatzis, Ioannis Chynkiamis, Nikolaos Armstrong, Matthew Lane, Nicholas D. Hartley, Tom Gray, William K. Bourke, Stephen C. |
author_sort | Vogiatzis, Ioannis |
collection | PubMed |
description | During exercise, non-invasive ventilation (NIV) prolongs endurance in chronic obstructive pulmonary disease (COPD), but routine use is impractical. The VitaBreath device provides portable NIV (pNIV); however, it can only be used during recovery. We assessed the effect of pNIV compared to pursed lip breathing (PLB) on exercise tolerance. Twenty-four COPD patients were randomised to a high-intensity (HI: 2-min at 80% peak work rate (WRpeak) alternated with 2-min recovery; n = 13), or a moderate-intensity (MOD: 6-min at 60% WRpeak alternated with 2-min recovery; n = 11) protocol, and within these groups two tests were performed using pNIV and PLB during recovery in balanced order. Upon completion, patients were provided with pNIV; use over 12 weeks was assessed. Compared to PLB, pNIV increased exercise tolerance (HI: by 5.2 ± 6.0 min; MOD: by 5.8 ± 6.7 min) (p < 0.05). With pNIV, mean inspiratory capacity increased and breathlessness decreased by clinically meaningful margins during recovery compared to the end of exercise (HI: by 140 ± 110 mL and 1.2 ± 1.7; MOD: by 170 ± 80 mL and 1.0 ± 0.7). At 12 weeks, patients reported that pNIV reduced anxiety (median: 7.5/10 versus 4/10, p = 0.001) and recovery time from breathlessness (17/24 patients; p = 0.002); 23/24 used the device at least weekly. pNIV increased exercise tolerance by reducing dynamic hyperinflation and breathlessness in COPD patients. |
format | Online Article Text |
id | pubmed-6352193 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63521932019-02-01 Intermittent Use of Portable NIV Increases Exercise Tolerance in COPD: A Randomised, Cross-Over Trial Vogiatzis, Ioannis Chynkiamis, Nikolaos Armstrong, Matthew Lane, Nicholas D. Hartley, Tom Gray, William K. Bourke, Stephen C. J Clin Med Article During exercise, non-invasive ventilation (NIV) prolongs endurance in chronic obstructive pulmonary disease (COPD), but routine use is impractical. The VitaBreath device provides portable NIV (pNIV); however, it can only be used during recovery. We assessed the effect of pNIV compared to pursed lip breathing (PLB) on exercise tolerance. Twenty-four COPD patients were randomised to a high-intensity (HI: 2-min at 80% peak work rate (WRpeak) alternated with 2-min recovery; n = 13), or a moderate-intensity (MOD: 6-min at 60% WRpeak alternated with 2-min recovery; n = 11) protocol, and within these groups two tests were performed using pNIV and PLB during recovery in balanced order. Upon completion, patients were provided with pNIV; use over 12 weeks was assessed. Compared to PLB, pNIV increased exercise tolerance (HI: by 5.2 ± 6.0 min; MOD: by 5.8 ± 6.7 min) (p < 0.05). With pNIV, mean inspiratory capacity increased and breathlessness decreased by clinically meaningful margins during recovery compared to the end of exercise (HI: by 140 ± 110 mL and 1.2 ± 1.7; MOD: by 170 ± 80 mL and 1.0 ± 0.7). At 12 weeks, patients reported that pNIV reduced anxiety (median: 7.5/10 versus 4/10, p = 0.001) and recovery time from breathlessness (17/24 patients; p = 0.002); 23/24 used the device at least weekly. pNIV increased exercise tolerance by reducing dynamic hyperinflation and breathlessness in COPD patients. MDPI 2019-01-15 /pmc/articles/PMC6352193/ /pubmed/30650617 http://dx.doi.org/10.3390/jcm8010094 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Vogiatzis, Ioannis Chynkiamis, Nikolaos Armstrong, Matthew Lane, Nicholas D. Hartley, Tom Gray, William K. Bourke, Stephen C. Intermittent Use of Portable NIV Increases Exercise Tolerance in COPD: A Randomised, Cross-Over Trial |
title | Intermittent Use of Portable NIV Increases Exercise Tolerance in COPD: A Randomised, Cross-Over Trial |
title_full | Intermittent Use of Portable NIV Increases Exercise Tolerance in COPD: A Randomised, Cross-Over Trial |
title_fullStr | Intermittent Use of Portable NIV Increases Exercise Tolerance in COPD: A Randomised, Cross-Over Trial |
title_full_unstemmed | Intermittent Use of Portable NIV Increases Exercise Tolerance in COPD: A Randomised, Cross-Over Trial |
title_short | Intermittent Use of Portable NIV Increases Exercise Tolerance in COPD: A Randomised, Cross-Over Trial |
title_sort | intermittent use of portable niv increases exercise tolerance in copd: a randomised, cross-over trial |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352193/ https://www.ncbi.nlm.nih.gov/pubmed/30650617 http://dx.doi.org/10.3390/jcm8010094 |
work_keys_str_mv | AT vogiatzisioannis intermittentuseofportablenivincreasesexercisetoleranceincopdarandomisedcrossovertrial AT chynkiamisnikolaos intermittentuseofportablenivincreasesexercisetoleranceincopdarandomisedcrossovertrial AT armstrongmatthew intermittentuseofportablenivincreasesexercisetoleranceincopdarandomisedcrossovertrial AT lanenicholasd intermittentuseofportablenivincreasesexercisetoleranceincopdarandomisedcrossovertrial AT hartleytom intermittentuseofportablenivincreasesexercisetoleranceincopdarandomisedcrossovertrial AT graywilliamk intermittentuseofportablenivincreasesexercisetoleranceincopdarandomisedcrossovertrial AT bourkestephenc intermittentuseofportablenivincreasesexercisetoleranceincopdarandomisedcrossovertrial |