Recurrent (99m)Tc Sestamibi Emboli in the Lungs Revealed on Consecutive Rest and Stress Single-Photon Emission Computed Tomography/Computed Tomography Myocardial Perfusion Images
Many causes of incidental focal uptake on raw data images using myocardial perfusion imaging, including malignant diseases, metastatic processes, benign pathologies, and physiological conditions, have been reported in the literature. However, iatrogenic (99m)Tc sestamibi emboli have not yet been rep...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352637/ https://www.ncbi.nlm.nih.gov/pubmed/30713388 http://dx.doi.org/10.4103/ijnm.IJNM_108_18 |
_version_ | 1783390883175989248 |
---|---|
author | Ozguven, Salih Engur, Ceren Ozge Oksuzoglu, Kevser Ones, Tunc Erdil, Tanju Yusuf |
author_facet | Ozguven, Salih Engur, Ceren Ozge Oksuzoglu, Kevser Ones, Tunc Erdil, Tanju Yusuf |
author_sort | Ozguven, Salih |
collection | PubMed |
description | Many causes of incidental focal uptake on raw data images using myocardial perfusion imaging, including malignant diseases, metastatic processes, benign pathologies, and physiological conditions, have been reported in the literature. However, iatrogenic (99m)Tc sestamibi emboli have not yet been reported. Herein, we demonstrated iatrogenic (99m)Tc sestamibi embolization on consecutive rest and stressed myocardial perfusion images at different locations. |
format | Online Article Text |
id | pubmed-6352637 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-63526372019-02-01 Recurrent (99m)Tc Sestamibi Emboli in the Lungs Revealed on Consecutive Rest and Stress Single-Photon Emission Computed Tomography/Computed Tomography Myocardial Perfusion Images Ozguven, Salih Engur, Ceren Ozge Oksuzoglu, Kevser Ones, Tunc Erdil, Tanju Yusuf Indian J Nucl Med Interesting Image Many causes of incidental focal uptake on raw data images using myocardial perfusion imaging, including malignant diseases, metastatic processes, benign pathologies, and physiological conditions, have been reported in the literature. However, iatrogenic (99m)Tc sestamibi emboli have not yet been reported. Herein, we demonstrated iatrogenic (99m)Tc sestamibi embolization on consecutive rest and stressed myocardial perfusion images at different locations. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6352637/ /pubmed/30713388 http://dx.doi.org/10.4103/ijnm.IJNM_108_18 Text en Copyright: © 2019 Indian Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Interesting Image Ozguven, Salih Engur, Ceren Ozge Oksuzoglu, Kevser Ones, Tunc Erdil, Tanju Yusuf Recurrent (99m)Tc Sestamibi Emboli in the Lungs Revealed on Consecutive Rest and Stress Single-Photon Emission Computed Tomography/Computed Tomography Myocardial Perfusion Images |
title | Recurrent (99m)Tc Sestamibi Emboli in the Lungs Revealed on Consecutive Rest and Stress Single-Photon Emission Computed Tomography/Computed Tomography Myocardial Perfusion Images |
title_full | Recurrent (99m)Tc Sestamibi Emboli in the Lungs Revealed on Consecutive Rest and Stress Single-Photon Emission Computed Tomography/Computed Tomography Myocardial Perfusion Images |
title_fullStr | Recurrent (99m)Tc Sestamibi Emboli in the Lungs Revealed on Consecutive Rest and Stress Single-Photon Emission Computed Tomography/Computed Tomography Myocardial Perfusion Images |
title_full_unstemmed | Recurrent (99m)Tc Sestamibi Emboli in the Lungs Revealed on Consecutive Rest and Stress Single-Photon Emission Computed Tomography/Computed Tomography Myocardial Perfusion Images |
title_short | Recurrent (99m)Tc Sestamibi Emboli in the Lungs Revealed on Consecutive Rest and Stress Single-Photon Emission Computed Tomography/Computed Tomography Myocardial Perfusion Images |
title_sort | recurrent (99m)tc sestamibi emboli in the lungs revealed on consecutive rest and stress single-photon emission computed tomography/computed tomography myocardial perfusion images |
topic | Interesting Image |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6352637/ https://www.ncbi.nlm.nih.gov/pubmed/30713388 http://dx.doi.org/10.4103/ijnm.IJNM_108_18 |
work_keys_str_mv | AT ozguvensalih recurrent99mtcsestamibiemboliinthelungsrevealedonconsecutiverestandstresssinglephotonemissioncomputedtomographycomputedtomographymyocardialperfusionimages AT engurcerenozge recurrent99mtcsestamibiemboliinthelungsrevealedonconsecutiverestandstresssinglephotonemissioncomputedtomographycomputedtomographymyocardialperfusionimages AT oksuzoglukevser recurrent99mtcsestamibiemboliinthelungsrevealedonconsecutiverestandstresssinglephotonemissioncomputedtomographycomputedtomographymyocardialperfusionimages AT onestunc recurrent99mtcsestamibiemboliinthelungsrevealedonconsecutiverestandstresssinglephotonemissioncomputedtomographycomputedtomographymyocardialperfusionimages AT erdiltanjuyusuf recurrent99mtcsestamibiemboliinthelungsrevealedonconsecutiverestandstresssinglephotonemissioncomputedtomographycomputedtomographymyocardialperfusionimages |