Cargando…

Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement

The expanded polytetrafluoroethylene (ePTFE) heart valve can serve as a viable option for prosthetic aortic valve. In this study, an ePTFE bi-leaflet valve design for aortic valve replacement (AVR) is presented, and the performance of the proposed valve was assessed numerically and experimentally. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Guangyu, Ismail, Munirah Binte, Nakao, Masakazu, Yuan, Qi, Yeo, Joon Hock
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6353165/
https://www.ncbi.nlm.nih.gov/pubmed/30699210
http://dx.doi.org/10.1371/journal.pone.0210780
_version_ 1783390972937240576
author Zhu, Guangyu
Ismail, Munirah Binte
Nakao, Masakazu
Yuan, Qi
Yeo, Joon Hock
author_facet Zhu, Guangyu
Ismail, Munirah Binte
Nakao, Masakazu
Yuan, Qi
Yeo, Joon Hock
author_sort Zhu, Guangyu
collection PubMed
description The expanded polytetrafluoroethylene (ePTFE) heart valve can serve as a viable option for prosthetic aortic valve. In this study, an ePTFE bi-leaflet valve design for aortic valve replacement (AVR) is presented, and the performance of the proposed valve was assessed numerically and experimentally. The valve was designed using CAE software. The dynamic behavior of the newly designed bi-leaflet valve under time-varying physiological pressure loading was first investigated by using commercial finite element code. Then, in-vitro tests were performed to validate the simulation and to assess the hemodynamic performance of the proposed design. A tri-leaflet ePTFE valve was tested in-vitro under the same conditions as a reference. The maximum leaflet coaptation area of the bi-leaflet valve during diastole was 216.3 mm(2). When fully closed, no leakage gap was observed and the free edges of the molded valve formed S-shaped lines. The maximum Von Mises stress during a full cardiac cycle was 4.20 MPa. The dynamic performance of the bi-leaflet valve was validated by the in-vitro test under physiological aortic pressure pulse. The effective orifice area (EOA), mean pressure gradient, regurgitant volume, leakage volume and energy loss of the proposed valve were 3.14 cm(2), 8.74 mmHg, 5.93 ml/beat, 1.55 ml/beat and 98.99 mJ, respectively. This study reports a novel bi-leaflet valve design for AVR. The performance of the proposed valve was numerically and experimentally assessed. Compared with the reference valve, the proposed design exhibited better structural and hemodynamic performances, which improved valve competency. Moreover, the performance of the bi-leaflet design is comparable to commercialized valves available on the market. The results of the present study provide a viable option for the future clinical applications.
format Online
Article
Text
id pubmed-6353165
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-63531652019-02-15 Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement Zhu, Guangyu Ismail, Munirah Binte Nakao, Masakazu Yuan, Qi Yeo, Joon Hock PLoS One Research Article The expanded polytetrafluoroethylene (ePTFE) heart valve can serve as a viable option for prosthetic aortic valve. In this study, an ePTFE bi-leaflet valve design for aortic valve replacement (AVR) is presented, and the performance of the proposed valve was assessed numerically and experimentally. The valve was designed using CAE software. The dynamic behavior of the newly designed bi-leaflet valve under time-varying physiological pressure loading was first investigated by using commercial finite element code. Then, in-vitro tests were performed to validate the simulation and to assess the hemodynamic performance of the proposed design. A tri-leaflet ePTFE valve was tested in-vitro under the same conditions as a reference. The maximum leaflet coaptation area of the bi-leaflet valve during diastole was 216.3 mm(2). When fully closed, no leakage gap was observed and the free edges of the molded valve formed S-shaped lines. The maximum Von Mises stress during a full cardiac cycle was 4.20 MPa. The dynamic performance of the bi-leaflet valve was validated by the in-vitro test under physiological aortic pressure pulse. The effective orifice area (EOA), mean pressure gradient, regurgitant volume, leakage volume and energy loss of the proposed valve were 3.14 cm(2), 8.74 mmHg, 5.93 ml/beat, 1.55 ml/beat and 98.99 mJ, respectively. This study reports a novel bi-leaflet valve design for AVR. The performance of the proposed valve was numerically and experimentally assessed. Compared with the reference valve, the proposed design exhibited better structural and hemodynamic performances, which improved valve competency. Moreover, the performance of the bi-leaflet design is comparable to commercialized valves available on the market. The results of the present study provide a viable option for the future clinical applications. Public Library of Science 2019-01-30 /pmc/articles/PMC6353165/ /pubmed/30699210 http://dx.doi.org/10.1371/journal.pone.0210780 Text en © 2019 Zhu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Zhu, Guangyu
Ismail, Munirah Binte
Nakao, Masakazu
Yuan, Qi
Yeo, Joon Hock
Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement
title Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement
title_full Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement
title_fullStr Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement
title_full_unstemmed Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement
title_short Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement
title_sort numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6353165/
https://www.ncbi.nlm.nih.gov/pubmed/30699210
http://dx.doi.org/10.1371/journal.pone.0210780
work_keys_str_mv AT zhuguangyu numericalandinvitroexperimentalassessmentoftheperformanceofanoveldesignedexpandedpolytetrafluoroethylenestentlessbileafletvalveforaorticvalvereplacement
AT ismailmunirahbinte numericalandinvitroexperimentalassessmentoftheperformanceofanoveldesignedexpandedpolytetrafluoroethylenestentlessbileafletvalveforaorticvalvereplacement
AT nakaomasakazu numericalandinvitroexperimentalassessmentoftheperformanceofanoveldesignedexpandedpolytetrafluoroethylenestentlessbileafletvalveforaorticvalvereplacement
AT yuanqi numericalandinvitroexperimentalassessmentoftheperformanceofanoveldesignedexpandedpolytetrafluoroethylenestentlessbileafletvalveforaorticvalvereplacement
AT yeojoonhock numericalandinvitroexperimentalassessmentoftheperformanceofanoveldesignedexpandedpolytetrafluoroethylenestentlessbileafletvalveforaorticvalvereplacement