Cargando…
Automated Generation of Radiologic Descriptions on Brain Volume Changes From T1-Weighted MR Images: Initial Assessment of Feasibility
Purpose: To examine the feasibility and potential difficulties of automatically generating radiologic reports (RRs) to articulate the clinically important features of brain magnetic resonance (MR) images. Materials and Methods: We focused on examining brain atrophy by using magnetization-prepared ra...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6354548/ https://www.ncbi.nlm.nih.gov/pubmed/30733701 http://dx.doi.org/10.3389/fneur.2019.00007 |
_version_ | 1783391193140297728 |
---|---|
author | Akazawa, Kentaro Sakamoto, Ryo Nakajima, Satoshi Wu, Dan Li, Yue Oishi, Kenichi Faria, Andreia V. Yamada, Kei Togashi, Kaori Lyketsos, Constantine G. Miller, Michael I. Mori, Susumu |
author_facet | Akazawa, Kentaro Sakamoto, Ryo Nakajima, Satoshi Wu, Dan Li, Yue Oishi, Kenichi Faria, Andreia V. Yamada, Kei Togashi, Kaori Lyketsos, Constantine G. Miller, Michael I. Mori, Susumu |
author_sort | Akazawa, Kentaro |
collection | PubMed |
description | Purpose: To examine the feasibility and potential difficulties of automatically generating radiologic reports (RRs) to articulate the clinically important features of brain magnetic resonance (MR) images. Materials and Methods: We focused on examining brain atrophy by using magnetization-prepared rapid gradient-echo (MPRAGE) images. The technology was based on multi-atlas whole-brain segmentation that identified 283 structures, from which larger superstructures were created to represent the anatomic units most frequently used in RRs. Through two layers of data-reduction filters, based on anatomic and clinical knowledge, raw images (~10 MB) were converted to a few kilobytes of human-readable sentences. The tool was applied to images from 92 patients with memory problems, and the results were compared to RRs independently produced by three experienced radiologists. The mechanisms of disagreement were investigated to understand where machine–human interface succeeded or failed. Results: The automatically generated sentences had low sensitivity (mean: 24.5%) and precision (mean: 24.9%) values; these were significantly lower than the inter-rater sensitivity (mean: 32.7%) and precision (mean: 32.2%) of the radiologists. The causes of disagreement were divided into six error categories: mismatch of anatomic definitions (7.2 ± 9.3%), data-reduction errors (11.4 ± 3.9%), translator errors (3.1 ± 3.1%), difference in the spatial extent of used anatomic terms (8.3 ± 6.7%), segmentation quality (9.8 ± 2.0%), and threshold for sentence-triggering (60.2 ± 16.3%). Conclusion: These error mechanisms raise interesting questions about the potential of automated report generation and the quality of image reading by humans. The most significant discrepancy between the human and automatically generated RRs was caused by the sentence-triggering threshold (the degree of abnormality), which was fixed to z-score >2.0 for the automated generation, while the thresholds by radiologists varied among different anatomical structures. |
format | Online Article Text |
id | pubmed-6354548 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-63545482019-02-07 Automated Generation of Radiologic Descriptions on Brain Volume Changes From T1-Weighted MR Images: Initial Assessment of Feasibility Akazawa, Kentaro Sakamoto, Ryo Nakajima, Satoshi Wu, Dan Li, Yue Oishi, Kenichi Faria, Andreia V. Yamada, Kei Togashi, Kaori Lyketsos, Constantine G. Miller, Michael I. Mori, Susumu Front Neurol Neurology Purpose: To examine the feasibility and potential difficulties of automatically generating radiologic reports (RRs) to articulate the clinically important features of brain magnetic resonance (MR) images. Materials and Methods: We focused on examining brain atrophy by using magnetization-prepared rapid gradient-echo (MPRAGE) images. The technology was based on multi-atlas whole-brain segmentation that identified 283 structures, from which larger superstructures were created to represent the anatomic units most frequently used in RRs. Through two layers of data-reduction filters, based on anatomic and clinical knowledge, raw images (~10 MB) were converted to a few kilobytes of human-readable sentences. The tool was applied to images from 92 patients with memory problems, and the results were compared to RRs independently produced by three experienced radiologists. The mechanisms of disagreement were investigated to understand where machine–human interface succeeded or failed. Results: The automatically generated sentences had low sensitivity (mean: 24.5%) and precision (mean: 24.9%) values; these were significantly lower than the inter-rater sensitivity (mean: 32.7%) and precision (mean: 32.2%) of the radiologists. The causes of disagreement were divided into six error categories: mismatch of anatomic definitions (7.2 ± 9.3%), data-reduction errors (11.4 ± 3.9%), translator errors (3.1 ± 3.1%), difference in the spatial extent of used anatomic terms (8.3 ± 6.7%), segmentation quality (9.8 ± 2.0%), and threshold for sentence-triggering (60.2 ± 16.3%). Conclusion: These error mechanisms raise interesting questions about the potential of automated report generation and the quality of image reading by humans. The most significant discrepancy between the human and automatically generated RRs was caused by the sentence-triggering threshold (the degree of abnormality), which was fixed to z-score >2.0 for the automated generation, while the thresholds by radiologists varied among different anatomical structures. Frontiers Media S.A. 2019-01-24 /pmc/articles/PMC6354548/ /pubmed/30733701 http://dx.doi.org/10.3389/fneur.2019.00007 Text en Copyright © Akazawa, Sakamoto, Nakajima, Wu, Li, Oishi, Faria, Yamada, Togashi, Lyketsos, Miller and Mori. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Akazawa, Kentaro Sakamoto, Ryo Nakajima, Satoshi Wu, Dan Li, Yue Oishi, Kenichi Faria, Andreia V. Yamada, Kei Togashi, Kaori Lyketsos, Constantine G. Miller, Michael I. Mori, Susumu Automated Generation of Radiologic Descriptions on Brain Volume Changes From T1-Weighted MR Images: Initial Assessment of Feasibility |
title | Automated Generation of Radiologic Descriptions on Brain Volume Changes From T1-Weighted MR Images: Initial Assessment of Feasibility |
title_full | Automated Generation of Radiologic Descriptions on Brain Volume Changes From T1-Weighted MR Images: Initial Assessment of Feasibility |
title_fullStr | Automated Generation of Radiologic Descriptions on Brain Volume Changes From T1-Weighted MR Images: Initial Assessment of Feasibility |
title_full_unstemmed | Automated Generation of Radiologic Descriptions on Brain Volume Changes From T1-Weighted MR Images: Initial Assessment of Feasibility |
title_short | Automated Generation of Radiologic Descriptions on Brain Volume Changes From T1-Weighted MR Images: Initial Assessment of Feasibility |
title_sort | automated generation of radiologic descriptions on brain volume changes from t1-weighted mr images: initial assessment of feasibility |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6354548/ https://www.ncbi.nlm.nih.gov/pubmed/30733701 http://dx.doi.org/10.3389/fneur.2019.00007 |
work_keys_str_mv | AT akazawakentaro automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT sakamotoryo automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT nakajimasatoshi automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT wudan automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT liyue automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT oishikenichi automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT fariaandreiav automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT yamadakei automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT togashikaori automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT lyketsosconstantineg automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT millermichaeli automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility AT morisusumu automatedgenerationofradiologicdescriptionsonbrainvolumechangesfromt1weightedmrimagesinitialassessmentoffeasibility |