Cargando…
Predicting ambulatory energy expenditure in lower limb amputees using multi-sensor methods
PURPOSE: To assess the validity of a derived algorithm, combining tri-axial accelerometry and heart rate (HR) data, compared to a research-grade multi-sensor physical activity device, for the estimation of ambulatory physical activity energy expenditure (PAEE) in individuals with traumatic lower-lim...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6354995/ https://www.ncbi.nlm.nih.gov/pubmed/30703115 http://dx.doi.org/10.1371/journal.pone.0209249 |
Sumario: | PURPOSE: To assess the validity of a derived algorithm, combining tri-axial accelerometry and heart rate (HR) data, compared to a research-grade multi-sensor physical activity device, for the estimation of ambulatory physical activity energy expenditure (PAEE) in individuals with traumatic lower-limb amputation. METHODS: Twenty-eight participants [unilateral (n = 9), bilateral (n = 10) with lower-limb amputations, and non-injured controls (n = 9)] completed eight activities; rest, ambulating at 5 progressive treadmill velocities (0.48, 0.67, 0.89, 1.12, 1.34m.s(-1)) and 2 gradients (3 and 5%) at 0.89m.s(-1). During each task, expired gases were collected for the determination of [Image: see text] and subsequent calculation of PAEE. An Actigraph GT3X+ accelerometer was worn on the hip of the shortest residual limb and, a HR monitor and an Actiheart (AHR) device were worn on the chest. Multiple linear regressions were employed to derive population-specific PAEE estimated algorithms using Actigraph GT3X+ outputs and HR signals (GT3X+HR). Mean bias±95% Limits of Agreement (LoA) and error statistics were calculated between criterion PAEE (indirect calorimetry) and PAEE predicted using GT3X+HR and AHR. RESULTS: Both measurement approaches used to predict PAEE were significantly related (P<0.01) with criterion PAEE. GT3X+HR revealed the strongest association, smallest LoA and least error. Predicted PAEE (GT3X+HR; unilateral; r = 0.92, bilateral; r = 0.93, and control; r = 0.91, and AHR; unilateral; r = 0.86, bilateral; r = 0.81, and control; r = 0.67). Mean±SD percent error across all activities were 18±14%, 15±12% and 15±14% for the GT3X+HR and 45±20%, 39±23% and 34±28% in the AHR model, for unilateral, bilateral and control groups, respectively. CONCLUSIONS: Statistically derived algorithms (GT3X+HR) provide a more valid estimate of PAEE in individuals with traumatic lower-limb amputation, compared to a proprietary group calibration algorithm (AHR). Outputs from AHR displayed considerable random error when tested in a laboratory setting in individuals with lower-limb amputation. |
---|