Cargando…

Phase analysis single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) detects dyssynchrony in myocardial scar and increases specificity of MPI

BACKGROUND: Myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT) is commonly used to assess patients with cardiovascular disease. However, in certain scenarios, it may have limited specificity in the identification of hemodynamically significant coronary artery...

Descripción completa

Detalles Bibliográficos
Autores principales: Bois, John P., Scott, Chris, Chareonthaitawee, Panithaya, Gibbons, Raymond J., Rodriguez-Porcel, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6355889/
https://www.ncbi.nlm.nih.gov/pubmed/30706258
http://dx.doi.org/10.1186/s13550-019-0476-y
_version_ 1783391411691847680
author Bois, John P.
Scott, Chris
Chareonthaitawee, Panithaya
Gibbons, Raymond J.
Rodriguez-Porcel, Martin
author_facet Bois, John P.
Scott, Chris
Chareonthaitawee, Panithaya
Gibbons, Raymond J.
Rodriguez-Porcel, Martin
author_sort Bois, John P.
collection PubMed
description BACKGROUND: Myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT) is commonly used to assess patients with cardiovascular disease. However, in certain scenarios, it may have limited specificity in the identification of hemodynamically significant coronary artery disease (e.g., false positive), potentially resulting in additional unnecessary testing and treatment. Phase analysis (PA) is an emerging, highly reproducible quantitative technology that can differentiate normal myocardial activation (synchrony) from myocardial scar (dyssynchrony). The objective of this study is to determine if PA can improve the specificity SPECT MPI. METHODS: An initial cohort of 340 patients (derivation cohort), referred for SPECT-MPI, was prospectively enrolled. Resting MPI studies were assessed for resting perfusion defects (scar). These were utilized as the reference standard for scar. Subsequently, we collected a second independent validation cohort of 138 patients and tested the potential of PA to reclassify patients for the diagnosis of “scar” or “no scar.” Patients were assigned to three categories depending upon their pre-test probability of scar based on multiple clinical and imaging parameters: ≤ 10% (no scar), 11–74% (indeterminate), and ≥ 75% (scar). The ability of PA variables to reclassify patients with scar to a higher group and those without scar to a lower group was then determined using the net reclassification index (NRI). RESULTS: Entropy (≥ 59%) was independently associated with scar in both patient cohorts with an odds ratio greater than five. Furthermore, when added to multiple clinical/imaging variables, the use of entropy significantly improved the area under the curve for assessment of scar (0.67 vs. 0.59, p = 0.04). The use of entropy correctly reclassified 24% of patients without scar, by clinical model, to a lower risk category (as determined by pre-test probability) with an overall NRI of 18% in this validation cohort. DISCUSSION: The use of PA entropy can improve the specificity of SPECT MPI and may serve as a useful adjunctive tool to the interpreting physician. The current study determined the optimal PA parameters to detect scar (derivation cohort) and applied these parameters to a second, independent, patient group and noted that entropy (≥ 59%) was independently associated with scar in both patient cohorts. Therefore, PA, which requires no additional imaging time or radiation, enhances the diagnostic capabilities of SPECT MPI. CONCLUSION: The use of PA entropy significantly improved the specificity of SPECT MPI and could influence the labeling of a patient as having or not having myocardial scar and thereby may influence not only diagnostic reporting but also potentially prognostic determination and therapeutic decision-making.
format Online
Article
Text
id pubmed-6355889
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-63558892019-02-24 Phase analysis single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) detects dyssynchrony in myocardial scar and increases specificity of MPI Bois, John P. Scott, Chris Chareonthaitawee, Panithaya Gibbons, Raymond J. Rodriguez-Porcel, Martin EJNMMI Res Original Research BACKGROUND: Myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT) is commonly used to assess patients with cardiovascular disease. However, in certain scenarios, it may have limited specificity in the identification of hemodynamically significant coronary artery disease (e.g., false positive), potentially resulting in additional unnecessary testing and treatment. Phase analysis (PA) is an emerging, highly reproducible quantitative technology that can differentiate normal myocardial activation (synchrony) from myocardial scar (dyssynchrony). The objective of this study is to determine if PA can improve the specificity SPECT MPI. METHODS: An initial cohort of 340 patients (derivation cohort), referred for SPECT-MPI, was prospectively enrolled. Resting MPI studies were assessed for resting perfusion defects (scar). These were utilized as the reference standard for scar. Subsequently, we collected a second independent validation cohort of 138 patients and tested the potential of PA to reclassify patients for the diagnosis of “scar” or “no scar.” Patients were assigned to three categories depending upon their pre-test probability of scar based on multiple clinical and imaging parameters: ≤ 10% (no scar), 11–74% (indeterminate), and ≥ 75% (scar). The ability of PA variables to reclassify patients with scar to a higher group and those without scar to a lower group was then determined using the net reclassification index (NRI). RESULTS: Entropy (≥ 59%) was independently associated with scar in both patient cohorts with an odds ratio greater than five. Furthermore, when added to multiple clinical/imaging variables, the use of entropy significantly improved the area under the curve for assessment of scar (0.67 vs. 0.59, p = 0.04). The use of entropy correctly reclassified 24% of patients without scar, by clinical model, to a lower risk category (as determined by pre-test probability) with an overall NRI of 18% in this validation cohort. DISCUSSION: The use of PA entropy can improve the specificity of SPECT MPI and may serve as a useful adjunctive tool to the interpreting physician. The current study determined the optimal PA parameters to detect scar (derivation cohort) and applied these parameters to a second, independent, patient group and noted that entropy (≥ 59%) was independently associated with scar in both patient cohorts. Therefore, PA, which requires no additional imaging time or radiation, enhances the diagnostic capabilities of SPECT MPI. CONCLUSION: The use of PA entropy significantly improved the specificity of SPECT MPI and could influence the labeling of a patient as having or not having myocardial scar and thereby may influence not only diagnostic reporting but also potentially prognostic determination and therapeutic decision-making. Springer Berlin Heidelberg 2019-01-31 /pmc/articles/PMC6355889/ /pubmed/30706258 http://dx.doi.org/10.1186/s13550-019-0476-y Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Bois, John P.
Scott, Chris
Chareonthaitawee, Panithaya
Gibbons, Raymond J.
Rodriguez-Porcel, Martin
Phase analysis single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) detects dyssynchrony in myocardial scar and increases specificity of MPI
title Phase analysis single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) detects dyssynchrony in myocardial scar and increases specificity of MPI
title_full Phase analysis single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) detects dyssynchrony in myocardial scar and increases specificity of MPI
title_fullStr Phase analysis single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) detects dyssynchrony in myocardial scar and increases specificity of MPI
title_full_unstemmed Phase analysis single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) detects dyssynchrony in myocardial scar and increases specificity of MPI
title_short Phase analysis single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) detects dyssynchrony in myocardial scar and increases specificity of MPI
title_sort phase analysis single-photon emission computed tomography (spect) myocardial perfusion imaging (mpi) detects dyssynchrony in myocardial scar and increases specificity of mpi
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6355889/
https://www.ncbi.nlm.nih.gov/pubmed/30706258
http://dx.doi.org/10.1186/s13550-019-0476-y
work_keys_str_mv AT boisjohnp phaseanalysissinglephotonemissioncomputedtomographyspectmyocardialperfusionimagingmpidetectsdyssynchronyinmyocardialscarandincreasesspecificityofmpi
AT scottchris phaseanalysissinglephotonemissioncomputedtomographyspectmyocardialperfusionimagingmpidetectsdyssynchronyinmyocardialscarandincreasesspecificityofmpi
AT chareonthaitaweepanithaya phaseanalysissinglephotonemissioncomputedtomographyspectmyocardialperfusionimagingmpidetectsdyssynchronyinmyocardialscarandincreasesspecificityofmpi
AT gibbonsraymondj phaseanalysissinglephotonemissioncomputedtomographyspectmyocardialperfusionimagingmpidetectsdyssynchronyinmyocardialscarandincreasesspecificityofmpi
AT rodriguezporcelmartin phaseanalysissinglephotonemissioncomputedtomographyspectmyocardialperfusionimagingmpidetectsdyssynchronyinmyocardialscarandincreasesspecificityofmpi