Comparison of Stress-Impedance Effect in Amorphous Ribbons with Positive and Negative Magnetostriction

The SI (stress-impedance) effect in amorphous ribbons with varying magnetostriction was investigated. Iron- and cobalt-based ribbons with different magnetostriction coefficients were put under tensile stress in a dead weight tester and the impedance change was investigated in function of applied str...

Descripción completa

Detalles Bibliográficos
Autores principales: Gazda, Piotr, Nowicki, Michał, Szewczyk, Roman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6357023/
https://www.ncbi.nlm.nih.gov/pubmed/30654466
http://dx.doi.org/10.3390/ma12020275
Descripción
Sumario:The SI (stress-impedance) effect in amorphous ribbons with varying magnetostriction was investigated. Iron- and cobalt-based ribbons with different magnetostriction coefficients were put under tensile stress in a dead weight tester and the impedance change was investigated in function of applied stresses. Significant differences of characteristics are presented. Stress-impedance analog of Villari reversal point was observed. The reversal point showed driving current frequency dependence, in which this point manifests for different stress values. Based on the obtained SI characteristics and magnetoelastic hysteresis, the most appropriate stress-sensing material was selected for development of precise small forces sensor.