Cargando…

Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system

We evaluated the potential differences of a digital positron-emission tomography (PET) prototype equipped with photon-counting detectors (D-PET, Philips Healthcare, Cleveland, Ohio, USA) in tumor volume delineation compared with the analog Gemini TF PET system (A-PET, Philips). Eleven oncologic pati...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, Nghi C., Vercher-Conejero, Jose, Faulhaber, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6357708/
https://www.ncbi.nlm.nih.gov/pubmed/30774546
http://dx.doi.org/10.4103/wjnm.WJNM_22_18
_version_ 1783391866094354432
author Nguyen, Nghi C.
Vercher-Conejero, Jose
Faulhaber, Peter
author_facet Nguyen, Nghi C.
Vercher-Conejero, Jose
Faulhaber, Peter
author_sort Nguyen, Nghi C.
collection PubMed
description We evaluated the potential differences of a digital positron-emission tomography (PET) prototype equipped with photon-counting detectors (D-PET, Philips Healthcare, Cleveland, Ohio, USA) in tumor volume delineation compared with the analog Gemini TF PET system (A-PET, Philips). Eleven oncologic patients first underwent clinical fluorodeoxyglucose (FDG) PET/computed tomography (CT) on A-PET. The D-PET ring was then inserted between the PET and CT scanner of A-PET and the patient was scanned for the second time. Two interpreters reviewed the two sets of PET/CT images for image quality and diagnostic confidence. FDG avid lesions were evaluated for volume measured at 35% and 50% of maximum standard uptake value (SUV) thresholds (35% SUV, 50% SUV), and for SUV gradient as a measure of lesion sharpness. Bland–Altman plots were used to assess the agreement between the two PET scans. Qualitative lesion conspicuity, sharpness, and diagnostic confidence were greater at D-PET than that of A-PET with favorable inter-rater agreements. Median lesion size of the 24 measured lesions was 1.6 cm. The lesion volume at D-PET was smaller at both 35% SUV and 50% SUV thresholds compared with that of A-PET, with a mean difference of − 3680.0 mm(3) at 35% SUV and − 835.3 mm(3) at 50% SUV. SUV gradient was greater at D-PET than at A-PET by 49.2% (95% confidence interval: 34.1%–60.8%). Given the smaller volume definition, coupled with improved conspicuity and sharpness, digital PET may be more robust and accurate in tumor rendering compared with analog PET not only for radiotherapy planning but also in prognostication and systemic treatment monitoring.
format Online
Article
Text
id pubmed-6357708
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-63577082019-02-17 Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system Nguyen, Nghi C. Vercher-Conejero, Jose Faulhaber, Peter World J Nucl Med Original Article We evaluated the potential differences of a digital positron-emission tomography (PET) prototype equipped with photon-counting detectors (D-PET, Philips Healthcare, Cleveland, Ohio, USA) in tumor volume delineation compared with the analog Gemini TF PET system (A-PET, Philips). Eleven oncologic patients first underwent clinical fluorodeoxyglucose (FDG) PET/computed tomography (CT) on A-PET. The D-PET ring was then inserted between the PET and CT scanner of A-PET and the patient was scanned for the second time. Two interpreters reviewed the two sets of PET/CT images for image quality and diagnostic confidence. FDG avid lesions were evaluated for volume measured at 35% and 50% of maximum standard uptake value (SUV) thresholds (35% SUV, 50% SUV), and for SUV gradient as a measure of lesion sharpness. Bland–Altman plots were used to assess the agreement between the two PET scans. Qualitative lesion conspicuity, sharpness, and diagnostic confidence were greater at D-PET than that of A-PET with favorable inter-rater agreements. Median lesion size of the 24 measured lesions was 1.6 cm. The lesion volume at D-PET was smaller at both 35% SUV and 50% SUV thresholds compared with that of A-PET, with a mean difference of − 3680.0 mm(3) at 35% SUV and − 835.3 mm(3) at 50% SUV. SUV gradient was greater at D-PET than at A-PET by 49.2% (95% confidence interval: 34.1%–60.8%). Given the smaller volume definition, coupled with improved conspicuity and sharpness, digital PET may be more robust and accurate in tumor rendering compared with analog PET not only for radiotherapy planning but also in prognostication and systemic treatment monitoring. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6357708/ /pubmed/30774546 http://dx.doi.org/10.4103/wjnm.WJNM_22_18 Text en Copyright: © 2019 World Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Nguyen, Nghi C.
Vercher-Conejero, Jose
Faulhaber, Peter
Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system
title Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system
title_full Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system
title_fullStr Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system
title_full_unstemmed Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system
title_short Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system
title_sort tumor volume delineation: a pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6357708/
https://www.ncbi.nlm.nih.gov/pubmed/30774546
http://dx.doi.org/10.4103/wjnm.WJNM_22_18
work_keys_str_mv AT nguyennghic tumorvolumedelineationapilotstudycomparingadigitalpositronemissiontomographyprototypewithananalogpositronemissiontomographysystem
AT vercherconejerojose tumorvolumedelineationapilotstudycomparingadigitalpositronemissiontomographyprototypewithananalogpositronemissiontomographysystem
AT faulhaberpeter tumorvolumedelineationapilotstudycomparingadigitalpositronemissiontomographyprototypewithananalogpositronemissiontomographysystem