Cargando…
Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system
We evaluated the potential differences of a digital positron-emission tomography (PET) prototype equipped with photon-counting detectors (D-PET, Philips Healthcare, Cleveland, Ohio, USA) in tumor volume delineation compared with the analog Gemini TF PET system (A-PET, Philips). Eleven oncologic pati...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6357708/ https://www.ncbi.nlm.nih.gov/pubmed/30774546 http://dx.doi.org/10.4103/wjnm.WJNM_22_18 |
_version_ | 1783391866094354432 |
---|---|
author | Nguyen, Nghi C. Vercher-Conejero, Jose Faulhaber, Peter |
author_facet | Nguyen, Nghi C. Vercher-Conejero, Jose Faulhaber, Peter |
author_sort | Nguyen, Nghi C. |
collection | PubMed |
description | We evaluated the potential differences of a digital positron-emission tomography (PET) prototype equipped with photon-counting detectors (D-PET, Philips Healthcare, Cleveland, Ohio, USA) in tumor volume delineation compared with the analog Gemini TF PET system (A-PET, Philips). Eleven oncologic patients first underwent clinical fluorodeoxyglucose (FDG) PET/computed tomography (CT) on A-PET. The D-PET ring was then inserted between the PET and CT scanner of A-PET and the patient was scanned for the second time. Two interpreters reviewed the two sets of PET/CT images for image quality and diagnostic confidence. FDG avid lesions were evaluated for volume measured at 35% and 50% of maximum standard uptake value (SUV) thresholds (35% SUV, 50% SUV), and for SUV gradient as a measure of lesion sharpness. Bland–Altman plots were used to assess the agreement between the two PET scans. Qualitative lesion conspicuity, sharpness, and diagnostic confidence were greater at D-PET than that of A-PET with favorable inter-rater agreements. Median lesion size of the 24 measured lesions was 1.6 cm. The lesion volume at D-PET was smaller at both 35% SUV and 50% SUV thresholds compared with that of A-PET, with a mean difference of − 3680.0 mm(3) at 35% SUV and − 835.3 mm(3) at 50% SUV. SUV gradient was greater at D-PET than at A-PET by 49.2% (95% confidence interval: 34.1%–60.8%). Given the smaller volume definition, coupled with improved conspicuity and sharpness, digital PET may be more robust and accurate in tumor rendering compared with analog PET not only for radiotherapy planning but also in prognostication and systemic treatment monitoring. |
format | Online Article Text |
id | pubmed-6357708 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-63577082019-02-17 Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system Nguyen, Nghi C. Vercher-Conejero, Jose Faulhaber, Peter World J Nucl Med Original Article We evaluated the potential differences of a digital positron-emission tomography (PET) prototype equipped with photon-counting detectors (D-PET, Philips Healthcare, Cleveland, Ohio, USA) in tumor volume delineation compared with the analog Gemini TF PET system (A-PET, Philips). Eleven oncologic patients first underwent clinical fluorodeoxyglucose (FDG) PET/computed tomography (CT) on A-PET. The D-PET ring was then inserted between the PET and CT scanner of A-PET and the patient was scanned for the second time. Two interpreters reviewed the two sets of PET/CT images for image quality and diagnostic confidence. FDG avid lesions were evaluated for volume measured at 35% and 50% of maximum standard uptake value (SUV) thresholds (35% SUV, 50% SUV), and for SUV gradient as a measure of lesion sharpness. Bland–Altman plots were used to assess the agreement between the two PET scans. Qualitative lesion conspicuity, sharpness, and diagnostic confidence were greater at D-PET than that of A-PET with favorable inter-rater agreements. Median lesion size of the 24 measured lesions was 1.6 cm. The lesion volume at D-PET was smaller at both 35% SUV and 50% SUV thresholds compared with that of A-PET, with a mean difference of − 3680.0 mm(3) at 35% SUV and − 835.3 mm(3) at 50% SUV. SUV gradient was greater at D-PET than at A-PET by 49.2% (95% confidence interval: 34.1%–60.8%). Given the smaller volume definition, coupled with improved conspicuity and sharpness, digital PET may be more robust and accurate in tumor rendering compared with analog PET not only for radiotherapy planning but also in prognostication and systemic treatment monitoring. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6357708/ /pubmed/30774546 http://dx.doi.org/10.4103/wjnm.WJNM_22_18 Text en Copyright: © 2019 World Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Nguyen, Nghi C. Vercher-Conejero, Jose Faulhaber, Peter Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system |
title | Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system |
title_full | Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system |
title_fullStr | Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system |
title_full_unstemmed | Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system |
title_short | Tumor volume delineation: A pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system |
title_sort | tumor volume delineation: a pilot study comparing a digital positron-emission tomography prototype with an analog positron-emission tomography system |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6357708/ https://www.ncbi.nlm.nih.gov/pubmed/30774546 http://dx.doi.org/10.4103/wjnm.WJNM_22_18 |
work_keys_str_mv | AT nguyennghic tumorvolumedelineationapilotstudycomparingadigitalpositronemissiontomographyprototypewithananalogpositronemissiontomographysystem AT vercherconejerojose tumorvolumedelineationapilotstudycomparingadigitalpositronemissiontomographyprototypewithananalogpositronemissiontomographysystem AT faulhaberpeter tumorvolumedelineationapilotstudycomparingadigitalpositronemissiontomographyprototypewithananalogpositronemissiontomographysystem |