Cargando…

Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure

The objective of this study is to investigate the sensitivity of contrast-enhanced transthoracic echocardiography (c-TTE) versus transesophageal echocardiography (TEE) to detect a residual right-to-left shunt (RLS) following a transcatheter patent foramen ovale (PFO) closure. A self-controlled study...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Hongling, Yue, Qingxiong, Wang, Tao, Wang, Lin, Pang, Zhanqi, Dong, He, Yang, Jian, Li, Yawen, Li, Shijun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6358410/
https://www.ncbi.nlm.nih.gov/pubmed/30681631
http://dx.doi.org/10.1097/MD.0000000000014276
_version_ 1783391999228903424
author Zhao, Hongling
Yue, Qingxiong
Wang, Tao
Wang, Lin
Pang, Zhanqi
Dong, He
Yang, Jian
Li, Yawen
Li, Shijun
author_facet Zhao, Hongling
Yue, Qingxiong
Wang, Tao
Wang, Lin
Pang, Zhanqi
Dong, He
Yang, Jian
Li, Yawen
Li, Shijun
author_sort Zhao, Hongling
collection PubMed
description The objective of this study is to investigate the sensitivity of contrast-enhanced transthoracic echocardiography (c-TTE) versus transesophageal echocardiography (TEE) to detect a residual right-to-left shunt (RLS) following a transcatheter patent foramen ovale (PFO) closure. A self-controlled study was conducted in a tertiary referral hospital. 57 patients with PFO who had experienced migraines underwent percutaneous PFO closure. c-TTE, TEE, and contrast-enhanced transcranial Doppler (c-TCD) at resting and Valsalva maneuver were performed during the 3-month follow-up after the closure. The closure devices were successfully implanted in all patients without complications. Three months after closure, TEE did not detect residual Valsalva shunts in any of the 57 patients; residual valsalva shunts were found via c-TTE in 15 of the 57 patients and were also observed via c-TCD. When c-TTE and/or c-TCD were used, the rate of residual RLSs detected in patients who underwent PFO closure was 26.32%, which was significantly different than the rate detected using TEE (P < .05) c-TTE and c-TCD showed equivalent sensitivity in evaluating transcatheter closure of a PFO. c-TTE could be a more cost-effective and reliable method to detect the residual shunt after PFO closure.
format Online
Article
Text
id pubmed-6358410
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-63584102019-02-15 Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure Zhao, Hongling Yue, Qingxiong Wang, Tao Wang, Lin Pang, Zhanqi Dong, He Yang, Jian Li, Yawen Li, Shijun Medicine (Baltimore) Research Article The objective of this study is to investigate the sensitivity of contrast-enhanced transthoracic echocardiography (c-TTE) versus transesophageal echocardiography (TEE) to detect a residual right-to-left shunt (RLS) following a transcatheter patent foramen ovale (PFO) closure. A self-controlled study was conducted in a tertiary referral hospital. 57 patients with PFO who had experienced migraines underwent percutaneous PFO closure. c-TTE, TEE, and contrast-enhanced transcranial Doppler (c-TCD) at resting and Valsalva maneuver were performed during the 3-month follow-up after the closure. The closure devices were successfully implanted in all patients without complications. Three months after closure, TEE did not detect residual Valsalva shunts in any of the 57 patients; residual valsalva shunts were found via c-TTE in 15 of the 57 patients and were also observed via c-TCD. When c-TTE and/or c-TCD were used, the rate of residual RLSs detected in patients who underwent PFO closure was 26.32%, which was significantly different than the rate detected using TEE (P < .05) c-TTE and c-TCD showed equivalent sensitivity in evaluating transcatheter closure of a PFO. c-TTE could be a more cost-effective and reliable method to detect the residual shunt after PFO closure. Wolters Kluwer Health 2019-01-25 /pmc/articles/PMC6358410/ /pubmed/30681631 http://dx.doi.org/10.1097/MD.0000000000014276 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle Research Article
Zhao, Hongling
Yue, Qingxiong
Wang, Tao
Wang, Lin
Pang, Zhanqi
Dong, He
Yang, Jian
Li, Yawen
Li, Shijun
Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure
title Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure
title_full Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure
title_fullStr Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure
title_full_unstemmed Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure
title_short Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure
title_sort sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6358410/
https://www.ncbi.nlm.nih.gov/pubmed/30681631
http://dx.doi.org/10.1097/MD.0000000000014276
work_keys_str_mv AT zhaohongling sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure
AT yueqingxiong sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure
AT wangtao sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure
AT wanglin sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure
AT pangzhanqi sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure
AT donghe sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure
AT yangjian sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure
AT liyawen sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure
AT lishijun sensitivityofcontrastenhancedtransthoracicechocardiographyforthedetectionofresidualshuntsafterpercutaneouspatentforamenovaleclosure