Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array

An unconstrained monitoring method for a driver’s heartbeat is investigated in this paper. Signal measurement was carried out by using pressure sensors array. Due to the inevitable changes of posture during driving, the monitoring place for heartbeat measurement needs to be adjusted accordingly. An...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Yongxiang, Deng, Sanpeng, Sun, Hongchang, Qi, Yuming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6358939/
https://www.ncbi.nlm.nih.gov/pubmed/30658466
http://dx.doi.org/10.3390/s19020368
_version_ 1783392106995253248
author Jiang, Yongxiang
Deng, Sanpeng
Sun, Hongchang
Qi, Yuming
author_facet Jiang, Yongxiang
Deng, Sanpeng
Sun, Hongchang
Qi, Yuming
author_sort Jiang, Yongxiang
collection PubMed
description An unconstrained monitoring method for a driver’s heartbeat is investigated in this paper. Signal measurement was carried out by using pressure sensors array. Due to the inevitable changes of posture during driving, the monitoring place for heartbeat measurement needs to be adjusted accordingly. An experiment was conducted to attach a pressure sensors array to the backrest of a seat. On the basis of the extreme learning machine classification method, driving posture can be recognized by monitoring the distribution of pressure signals. Then, a band-pass filter in heart rate range is adapted to the pressure signals in the frequency domain. Furthermore, a peak point array of the processed pressure frequency spectrum is derived and has the same distribution as the pressure signals. Thus, the heartbeat signals can be extracted from pressure sensors. Then, the correlation coefficient analysis of heartbeat signals and electrocardio-signals is performed. The results show a high level of correlation. Finally, the effects of driving posture on heartbeat signal extraction are discussed to obtain a theoretical foundation for measuring point real-time adjustment.
format Online
Article
Text
id pubmed-6358939
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63589392019-02-06 Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array Jiang, Yongxiang Deng, Sanpeng Sun, Hongchang Qi, Yuming Sensors (Basel) Article An unconstrained monitoring method for a driver’s heartbeat is investigated in this paper. Signal measurement was carried out by using pressure sensors array. Due to the inevitable changes of posture during driving, the monitoring place for heartbeat measurement needs to be adjusted accordingly. An experiment was conducted to attach a pressure sensors array to the backrest of a seat. On the basis of the extreme learning machine classification method, driving posture can be recognized by monitoring the distribution of pressure signals. Then, a band-pass filter in heart rate range is adapted to the pressure signals in the frequency domain. Furthermore, a peak point array of the processed pressure frequency spectrum is derived and has the same distribution as the pressure signals. Thus, the heartbeat signals can be extracted from pressure sensors. Then, the correlation coefficient analysis of heartbeat signals and electrocardio-signals is performed. The results show a high level of correlation. Finally, the effects of driving posture on heartbeat signal extraction are discussed to obtain a theoretical foundation for measuring point real-time adjustment. MDPI 2019-01-17 /pmc/articles/PMC6358939/ /pubmed/30658466 http://dx.doi.org/10.3390/s19020368 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jiang, Yongxiang
Deng, Sanpeng
Sun, Hongchang
Qi, Yuming
Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array
title Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array
title_full Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array
title_fullStr Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array
title_full_unstemmed Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array
title_short Unconstrained Monitoring Method for Heartbeat Signals Measurement using Pressure Sensors Array
title_sort unconstrained monitoring method for heartbeat signals measurement using pressure sensors array
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6358939/
https://www.ncbi.nlm.nih.gov/pubmed/30658466
http://dx.doi.org/10.3390/s19020368
work_keys_str_mv AT jiangyongxiang unconstrainedmonitoringmethodforheartbeatsignalsmeasurementusingpressuresensorsarray
AT dengsanpeng unconstrainedmonitoringmethodforheartbeatsignalsmeasurementusingpressuresensorsarray
AT sunhongchang unconstrainedmonitoringmethodforheartbeatsignalsmeasurementusingpressuresensorsarray
AT qiyuming unconstrainedmonitoringmethodforheartbeatsignalsmeasurementusingpressuresensorsarray