Cargando…
Acoustic Stimulation by Shunt-Diode Pre-Linearizer Using Very High Frequency Piezoelectric Transducer for Cancer Therapeutics
In this paper, we proposed cancer cell acoustic stimulation by shunt-diode pre-linearizer scheme using a very high frequency (≥100 MHz) piezoelectric transducer. To verify the concept of our proposed scheme, we performed pulse-echo detection, and accessed therapeutic effects of human cervical cancer...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6359139/ https://www.ncbi.nlm.nih.gov/pubmed/30654599 http://dx.doi.org/10.3390/s19020357 |
_version_ | 1783392161523302400 |
---|---|
author | Choi, Hojong Choe, Se-woon |
author_facet | Choi, Hojong Choe, Se-woon |
author_sort | Choi, Hojong |
collection | PubMed |
description | In this paper, we proposed cancer cell acoustic stimulation by shunt-diode pre-linearizer scheme using a very high frequency (≥100 MHz) piezoelectric transducer. To verify the concept of our proposed scheme, we performed pulse-echo detection, and accessed therapeutic effects of human cervical cancer cells exposed to acoustic stimulation experiments using 100 MHz focused piezoelectric transducer triggered by PA with and without the proposed shunt-diode pre-linearizer scheme. In the pulse-echo detection responses, the peak-to-peak voltage of the echo signal when using the PA with shunt-diode pre-linearizer (49.79 mV) was higher than that when using the PA alone (29.87 mV). In the experimental results, the cell densities of cancer cells on Day 4 when using no acoustic stimulation (control group), the very high-frequency piezoelectric transducer triggered by PA only and PA combined with proposed pre-linearizer schemes (1 V and 5 V DC bias voltages) showed 100%, 92.8 ± 4.2%, 84.2 ± 4.6%, and 78 ± 2.9%, respectively. Therefore, we confirmed that the shunt-diode pre-linearizer could improve the performances of the pulse signals of the PA, thus, enabling better therapeutic stimulation performances for cancer cell suppression. |
format | Online Article Text |
id | pubmed-6359139 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63591392019-02-06 Acoustic Stimulation by Shunt-Diode Pre-Linearizer Using Very High Frequency Piezoelectric Transducer for Cancer Therapeutics Choi, Hojong Choe, Se-woon Sensors (Basel) Article In this paper, we proposed cancer cell acoustic stimulation by shunt-diode pre-linearizer scheme using a very high frequency (≥100 MHz) piezoelectric transducer. To verify the concept of our proposed scheme, we performed pulse-echo detection, and accessed therapeutic effects of human cervical cancer cells exposed to acoustic stimulation experiments using 100 MHz focused piezoelectric transducer triggered by PA with and without the proposed shunt-diode pre-linearizer scheme. In the pulse-echo detection responses, the peak-to-peak voltage of the echo signal when using the PA with shunt-diode pre-linearizer (49.79 mV) was higher than that when using the PA alone (29.87 mV). In the experimental results, the cell densities of cancer cells on Day 4 when using no acoustic stimulation (control group), the very high-frequency piezoelectric transducer triggered by PA only and PA combined with proposed pre-linearizer schemes (1 V and 5 V DC bias voltages) showed 100%, 92.8 ± 4.2%, 84.2 ± 4.6%, and 78 ± 2.9%, respectively. Therefore, we confirmed that the shunt-diode pre-linearizer could improve the performances of the pulse signals of the PA, thus, enabling better therapeutic stimulation performances for cancer cell suppression. MDPI 2019-01-16 /pmc/articles/PMC6359139/ /pubmed/30654599 http://dx.doi.org/10.3390/s19020357 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Choi, Hojong Choe, Se-woon Acoustic Stimulation by Shunt-Diode Pre-Linearizer Using Very High Frequency Piezoelectric Transducer for Cancer Therapeutics |
title | Acoustic Stimulation by Shunt-Diode Pre-Linearizer Using Very High Frequency Piezoelectric Transducer for Cancer Therapeutics |
title_full | Acoustic Stimulation by Shunt-Diode Pre-Linearizer Using Very High Frequency Piezoelectric Transducer for Cancer Therapeutics |
title_fullStr | Acoustic Stimulation by Shunt-Diode Pre-Linearizer Using Very High Frequency Piezoelectric Transducer for Cancer Therapeutics |
title_full_unstemmed | Acoustic Stimulation by Shunt-Diode Pre-Linearizer Using Very High Frequency Piezoelectric Transducer for Cancer Therapeutics |
title_short | Acoustic Stimulation by Shunt-Diode Pre-Linearizer Using Very High Frequency Piezoelectric Transducer for Cancer Therapeutics |
title_sort | acoustic stimulation by shunt-diode pre-linearizer using very high frequency piezoelectric transducer for cancer therapeutics |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6359139/ https://www.ncbi.nlm.nih.gov/pubmed/30654599 http://dx.doi.org/10.3390/s19020357 |
work_keys_str_mv | AT choihojong acousticstimulationbyshuntdiodeprelinearizerusingveryhighfrequencypiezoelectrictransducerforcancertherapeutics AT choesewoon acousticstimulationbyshuntdiodeprelinearizerusingveryhighfrequencypiezoelectrictransducerforcancertherapeutics |