Cargando…

Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer

For the elimination of radio-frequency interference (RFI) in a passive microwave radiometer, the threshold level is generally calculated from the mean value and standard deviation. However, a serious problem that can arise is an error in the retrieved brightness temperature from a higher threshold l...

Descripción completa

Detalles Bibliográficos
Autores principales: Oh, Myeonggeun, Kim, Yong-Hoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6359279/
https://www.ncbi.nlm.nih.gov/pubmed/30646536
http://dx.doi.org/10.3390/s19020306
_version_ 1783392204894502912
author Oh, Myeonggeun
Kim, Yong-Hoon
author_facet Oh, Myeonggeun
Kim, Yong-Hoon
author_sort Oh, Myeonggeun
collection PubMed
description For the elimination of radio-frequency interference (RFI) in a passive microwave radiometer, the threshold level is generally calculated from the mean value and standard deviation. However, a serious problem that can arise is an error in the retrieved brightness temperature from a higher threshold level owing to the presence of RFI. In this paper, we propose a method to detect and mitigate RFI contamination using the threshold level from statistical criteria based on a spectrogram technique. Mean and skewness spectrograms are created from a brightness temperature spectrogram by shifting the 2-D window to discriminate the form of the symmetric distribution as a natural thermal emission signal. From the remaining bins of the mean spectrogram eliminated by RFI-flagged bins in the skewness spectrogram for data captured at 0.1-s intervals, two distribution sides are identically created from the left side of the distribution by changing the standard position of the distribution. Simultaneously, kurtosis calculations from these bins for each symmetric distribution are repeatedly performed to determine the retrieved brightness temperature corresponding to the closest kurtosis value of three. The performance is evaluated using experimental data, and the maximum error and root-mean-square error (RMSE) in the retrieved brightness temperature are served to be less than approximately 3 K and 1.7 K, respectively, from a window with a size of 100 × 100 time–frequency bins according to the RFI levels and cases.
format Online
Article
Text
id pubmed-6359279
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63592792019-02-06 Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer Oh, Myeonggeun Kim, Yong-Hoon Sensors (Basel) Article For the elimination of radio-frequency interference (RFI) in a passive microwave radiometer, the threshold level is generally calculated from the mean value and standard deviation. However, a serious problem that can arise is an error in the retrieved brightness temperature from a higher threshold level owing to the presence of RFI. In this paper, we propose a method to detect and mitigate RFI contamination using the threshold level from statistical criteria based on a spectrogram technique. Mean and skewness spectrograms are created from a brightness temperature spectrogram by shifting the 2-D window to discriminate the form of the symmetric distribution as a natural thermal emission signal. From the remaining bins of the mean spectrogram eliminated by RFI-flagged bins in the skewness spectrogram for data captured at 0.1-s intervals, two distribution sides are identically created from the left side of the distribution by changing the standard position of the distribution. Simultaneously, kurtosis calculations from these bins for each symmetric distribution are repeatedly performed to determine the retrieved brightness temperature corresponding to the closest kurtosis value of three. The performance is evaluated using experimental data, and the maximum error and root-mean-square error (RMSE) in the retrieved brightness temperature are served to be less than approximately 3 K and 1.7 K, respectively, from a window with a size of 100 × 100 time–frequency bins according to the RFI levels and cases. MDPI 2019-01-14 /pmc/articles/PMC6359279/ /pubmed/30646536 http://dx.doi.org/10.3390/s19020306 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oh, Myeonggeun
Kim, Yong-Hoon
Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer
title Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer
title_full Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer
title_fullStr Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer
title_full_unstemmed Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer
title_short Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer
title_sort statistical approach to spectrogram analysis for radio-frequency interference detection and mitigation in an l-band microwave radiometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6359279/
https://www.ncbi.nlm.nih.gov/pubmed/30646536
http://dx.doi.org/10.3390/s19020306
work_keys_str_mv AT ohmyeonggeun statisticalapproachtospectrogramanalysisforradiofrequencyinterferencedetectionandmitigationinanlbandmicrowaveradiometer
AT kimyonghoon statisticalapproachtospectrogramanalysisforradiofrequencyinterferencedetectionandmitigationinanlbandmicrowaveradiometer