Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report
Pneumothorax as a complication of pleural catheter insertion could be very dangerous in patients under mechanical ventilation. In ICU patients, physical examination and supine chest x-ray (CXR) are poorly sensitive in diagnosis of pneumothorax. Moreover, CT scan has also disadvantages, such as radia...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shiraz University of Medical Sciences
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6360002/ https://www.ncbi.nlm.nih.gov/pubmed/30719473 http://dx.doi.org/10.29252/beat-0701014 |
_version_ | 1783392385875574784 |
---|---|
author | Sabetian, Golnar Aalinezhad, Fatemeh Masjedi, Mansoor Paydar, Shahram |
author_facet | Sabetian, Golnar Aalinezhad, Fatemeh Masjedi, Mansoor Paydar, Shahram |
author_sort | Sabetian, Golnar |
collection | PubMed |
description | Pneumothorax as a complication of pleural catheter insertion could be very dangerous in patients under mechanical ventilation. In ICU patients, physical examination and supine chest x-ray (CXR) are poorly sensitive in diagnosis of pneumothorax. Moreover, CT scan has also disadvantages, such as radiation, high cost, time consuming and need for patient transfer to radiology suit. In comparison to CXR and CT scan, ultrasonography is an available tool for early and rapid detection of this complication. In this study, we reported a 21-year-old woman, a victim of trauma, undergone pleural catheter insertion for drainage of hemothorax. She developed pneumothorax after the procedure. We discuss the usefulness of ultrasonography after pleural catheter insertion and concluded its adequacy and effectiveness in early diagnosis and also follow-up of pneumothorax. |
format | Online Article Text |
id | pubmed-6360002 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Shiraz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-63600022019-02-04 Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report Sabetian, Golnar Aalinezhad, Fatemeh Masjedi, Mansoor Paydar, Shahram Bull Emerg Trauma Case Report Pneumothorax as a complication of pleural catheter insertion could be very dangerous in patients under mechanical ventilation. In ICU patients, physical examination and supine chest x-ray (CXR) are poorly sensitive in diagnosis of pneumothorax. Moreover, CT scan has also disadvantages, such as radiation, high cost, time consuming and need for patient transfer to radiology suit. In comparison to CXR and CT scan, ultrasonography is an available tool for early and rapid detection of this complication. In this study, we reported a 21-year-old woman, a victim of trauma, undergone pleural catheter insertion for drainage of hemothorax. She developed pneumothorax after the procedure. We discuss the usefulness of ultrasonography after pleural catheter insertion and concluded its adequacy and effectiveness in early diagnosis and also follow-up of pneumothorax. Shiraz University of Medical Sciences 2019-01 /pmc/articles/PMC6360002/ /pubmed/30719473 http://dx.doi.org/10.29252/beat-0701014 Text en © 2019 Trauma Research Center, Shiraz University of Medical Sciences Bulletin of Emergency And Trauma articles are published under a Creative Commons license. (http://creativecommons.org/licenses/) Mandated authors will be offered CC-BY; all other authors will choose between CC-BY, CC-BY-NC and CC-BY-NC-ND. |
spellingShingle | Case Report Sabetian, Golnar Aalinezhad, Fatemeh Masjedi, Mansoor Paydar, Shahram Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report |
title | Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report |
title_full | Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report |
title_fullStr | Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report |
title_full_unstemmed | Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report |
title_short | Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report |
title_sort | ultrasonography application for detection and management of pneumothorax following pleural catheter insertion; a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6360002/ https://www.ncbi.nlm.nih.gov/pubmed/30719473 http://dx.doi.org/10.29252/beat-0701014 |
work_keys_str_mv | AT sabetiangolnar ultrasonographyapplicationfordetectionandmanagementofpneumothoraxfollowingpleuralcatheterinsertionacasereport AT aalinezhadfatemeh ultrasonographyapplicationfordetectionandmanagementofpneumothoraxfollowingpleuralcatheterinsertionacasereport AT masjedimansoor ultrasonographyapplicationfordetectionandmanagementofpneumothoraxfollowingpleuralcatheterinsertionacasereport AT paydarshahram ultrasonographyapplicationfordetectionandmanagementofpneumothoraxfollowingpleuralcatheterinsertionacasereport |