Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report

Pneumothorax as a complication of pleural catheter insertion could be very dangerous in patients under mechanical ventilation. In ICU patients, physical examination and supine chest x-ray (CXR) are poorly sensitive in diagnosis of pneumothorax. Moreover, CT scan has also disadvantages, such as radia...

Descripción completa

Detalles Bibliográficos
Autores principales: Sabetian, Golnar, Aalinezhad, Fatemeh, Masjedi, Mansoor, Paydar, Shahram
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6360002/
https://www.ncbi.nlm.nih.gov/pubmed/30719473
http://dx.doi.org/10.29252/beat-0701014
_version_ 1783392385875574784
author Sabetian, Golnar
Aalinezhad, Fatemeh
Masjedi, Mansoor
Paydar, Shahram
author_facet Sabetian, Golnar
Aalinezhad, Fatemeh
Masjedi, Mansoor
Paydar, Shahram
author_sort Sabetian, Golnar
collection PubMed
description Pneumothorax as a complication of pleural catheter insertion could be very dangerous in patients under mechanical ventilation. In ICU patients, physical examination and supine chest x-ray (CXR) are poorly sensitive in diagnosis of pneumothorax. Moreover, CT scan has also disadvantages, such as radiation, high cost, time consuming and need for patient transfer to radiology suit. In comparison to CXR and CT scan, ultrasonography is an available tool for early and rapid detection of this complication. In this study, we reported a 21-year-old woman, a victim of trauma, undergone pleural catheter insertion for drainage of hemothorax. She developed pneumothorax after the procedure. We discuss the usefulness of ultrasonography after pleural catheter insertion and concluded its adequacy and effectiveness in early diagnosis and also follow-up of pneumothorax.
format Online
Article
Text
id pubmed-6360002
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-63600022019-02-04 Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report Sabetian, Golnar Aalinezhad, Fatemeh Masjedi, Mansoor Paydar, Shahram Bull Emerg Trauma Case Report Pneumothorax as a complication of pleural catheter insertion could be very dangerous in patients under mechanical ventilation. In ICU patients, physical examination and supine chest x-ray (CXR) are poorly sensitive in diagnosis of pneumothorax. Moreover, CT scan has also disadvantages, such as radiation, high cost, time consuming and need for patient transfer to radiology suit. In comparison to CXR and CT scan, ultrasonography is an available tool for early and rapid detection of this complication. In this study, we reported a 21-year-old woman, a victim of trauma, undergone pleural catheter insertion for drainage of hemothorax. She developed pneumothorax after the procedure. We discuss the usefulness of ultrasonography after pleural catheter insertion and concluded its adequacy and effectiveness in early diagnosis and also follow-up of pneumothorax. Shiraz University of Medical Sciences 2019-01 /pmc/articles/PMC6360002/ /pubmed/30719473 http://dx.doi.org/10.29252/beat-0701014 Text en © 2019 Trauma Research Center, Shiraz University of Medical Sciences Bulletin of Emergency And Trauma articles are published under a Creative Commons license. (http://creativecommons.org/licenses/) Mandated authors will be offered CC-BY; all other authors will choose between CC-BY, CC-BY-NC and CC-BY-NC-ND.
spellingShingle Case Report
Sabetian, Golnar
Aalinezhad, Fatemeh
Masjedi, Mansoor
Paydar, Shahram
Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report
title Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report
title_full Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report
title_fullStr Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report
title_full_unstemmed Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report
title_short Ultrasonography Application for Detection and Management of Pneumothorax following Pleural Catheter Insertion; A Case Report
title_sort ultrasonography application for detection and management of pneumothorax following pleural catheter insertion; a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6360002/
https://www.ncbi.nlm.nih.gov/pubmed/30719473
http://dx.doi.org/10.29252/beat-0701014
work_keys_str_mv AT sabetiangolnar ultrasonographyapplicationfordetectionandmanagementofpneumothoraxfollowingpleuralcatheterinsertionacasereport
AT aalinezhadfatemeh ultrasonographyapplicationfordetectionandmanagementofpneumothoraxfollowingpleuralcatheterinsertionacasereport
AT masjedimansoor ultrasonographyapplicationfordetectionandmanagementofpneumothoraxfollowingpleuralcatheterinsertionacasereport
AT paydarshahram ultrasonographyapplicationfordetectionandmanagementofpneumothoraxfollowingpleuralcatheterinsertionacasereport