Cargando…

Compliance with wrist-worn accelerometers in primiparous early postpartum women

BACKGROUND: There are few studies that objectively assess physical activity using accelerometry in postpartum women and none that do so before 3 months postpartum. It is not known whether accelerometry can be successfully used in the early postpartum period and thus benefit studies designed to asses...

Descripción completa

Detalles Bibliográficos
Autores principales: Wolpern, Ali E., Sherwin, Kyle J., Moss, Whitney D., Nygaard, Ingrid E., Egger, Marlene J., Brusseau, Timothy A., Shaw, Janet M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6360339/
https://www.ncbi.nlm.nih.gov/pubmed/30775582
http://dx.doi.org/10.1016/j.heliyon.2019.e01193
_version_ 1783392460320276480
author Wolpern, Ali E.
Sherwin, Kyle J.
Moss, Whitney D.
Nygaard, Ingrid E.
Egger, Marlene J.
Brusseau, Timothy A.
Shaw, Janet M.
author_facet Wolpern, Ali E.
Sherwin, Kyle J.
Moss, Whitney D.
Nygaard, Ingrid E.
Egger, Marlene J.
Brusseau, Timothy A.
Shaw, Janet M.
author_sort Wolpern, Ali E.
collection PubMed
description BACKGROUND: There are few studies that objectively assess physical activity using accelerometry in postpartum women and none that do so before 3 months postpartum. It is not known whether accelerometry can be successfully used in the early postpartum period and thus benefit studies designed to assess the health benefits and risks of early physical activity. Wear compliance may be substantially lower several weeks after childbirth, given the overwhelming nature of the early postpartum period, particularly for first time mothers. The aims of this study were to 1) describe the methods used to facilitate protocol compliance of wrist-worn accelerometry, 2) describe device usage and wear time in early postpartum primiparous women and 3) to place the compliance characteristics of early postpartum primiparous women in our study in context with that of other studies of postpartum women and standards published by large, physical activity surveillance studies. METHODS: Participants were primiparous women who were enrolled at 3(rd) trimester in a larger ongoing prospective cohort study, delivered vaginally, and lived in a 60 mile radius of the research site. The parent study was designed to evaluate the effects of early physical activity on pelvic floor health. Participants wore a wrist accelerometer (ActiGraph™ GT3XLink device) over two 7-day periods, 2–3 weeks and 5–6 weeks postpartum. We developed a protocol based on best practices to enhance compliance in this population. The Choi (2011) algorithm was used to determine wear time. RESULTS: Of all participants, 82.6% (166 of 201 eligible) and 70.1% (141 of 201 eligible) at 2–3 and 5–6 weeks, respectively, received and wore a functional device in the correct study time-frame for at least 7 days. Of participants that received a functional device, 94.3% (166/176) and 86.5% (141/163) wore the device for at least 7 days, with mean wear times of 1348.0 (135.8) minutes/day and 1313.5 (152) minutes/day, respectively. At 2–3 weeks, 96.1% and 90.4% met the NHANES and Whitehall II Study wear standards, respectively, while at 5–6 weeks, 93.9% and 84.1% did so. CONCLUSION: Despite challenges in conducting physical activity research in postpartum women, adherence to wrist-worn accelerometry is high with this protocol.
format Online
Article
Text
id pubmed-6360339
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-63603392019-02-15 Compliance with wrist-worn accelerometers in primiparous early postpartum women Wolpern, Ali E. Sherwin, Kyle J. Moss, Whitney D. Nygaard, Ingrid E. Egger, Marlene J. Brusseau, Timothy A. Shaw, Janet M. Heliyon Article BACKGROUND: There are few studies that objectively assess physical activity using accelerometry in postpartum women and none that do so before 3 months postpartum. It is not known whether accelerometry can be successfully used in the early postpartum period and thus benefit studies designed to assess the health benefits and risks of early physical activity. Wear compliance may be substantially lower several weeks after childbirth, given the overwhelming nature of the early postpartum period, particularly for first time mothers. The aims of this study were to 1) describe the methods used to facilitate protocol compliance of wrist-worn accelerometry, 2) describe device usage and wear time in early postpartum primiparous women and 3) to place the compliance characteristics of early postpartum primiparous women in our study in context with that of other studies of postpartum women and standards published by large, physical activity surveillance studies. METHODS: Participants were primiparous women who were enrolled at 3(rd) trimester in a larger ongoing prospective cohort study, delivered vaginally, and lived in a 60 mile radius of the research site. The parent study was designed to evaluate the effects of early physical activity on pelvic floor health. Participants wore a wrist accelerometer (ActiGraph™ GT3XLink device) over two 7-day periods, 2–3 weeks and 5–6 weeks postpartum. We developed a protocol based on best practices to enhance compliance in this population. The Choi (2011) algorithm was used to determine wear time. RESULTS: Of all participants, 82.6% (166 of 201 eligible) and 70.1% (141 of 201 eligible) at 2–3 and 5–6 weeks, respectively, received and wore a functional device in the correct study time-frame for at least 7 days. Of participants that received a functional device, 94.3% (166/176) and 86.5% (141/163) wore the device for at least 7 days, with mean wear times of 1348.0 (135.8) minutes/day and 1313.5 (152) minutes/day, respectively. At 2–3 weeks, 96.1% and 90.4% met the NHANES and Whitehall II Study wear standards, respectively, while at 5–6 weeks, 93.9% and 84.1% did so. CONCLUSION: Despite challenges in conducting physical activity research in postpartum women, adherence to wrist-worn accelerometry is high with this protocol. Elsevier 2019-01-31 /pmc/articles/PMC6360339/ /pubmed/30775582 http://dx.doi.org/10.1016/j.heliyon.2019.e01193 Text en © 2019 Published by Elsevier Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Wolpern, Ali E.
Sherwin, Kyle J.
Moss, Whitney D.
Nygaard, Ingrid E.
Egger, Marlene J.
Brusseau, Timothy A.
Shaw, Janet M.
Compliance with wrist-worn accelerometers in primiparous early postpartum women
title Compliance with wrist-worn accelerometers in primiparous early postpartum women
title_full Compliance with wrist-worn accelerometers in primiparous early postpartum women
title_fullStr Compliance with wrist-worn accelerometers in primiparous early postpartum women
title_full_unstemmed Compliance with wrist-worn accelerometers in primiparous early postpartum women
title_short Compliance with wrist-worn accelerometers in primiparous early postpartum women
title_sort compliance with wrist-worn accelerometers in primiparous early postpartum women
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6360339/
https://www.ncbi.nlm.nih.gov/pubmed/30775582
http://dx.doi.org/10.1016/j.heliyon.2019.e01193
work_keys_str_mv AT wolpernalie compliancewithwristwornaccelerometersinprimiparousearlypostpartumwomen
AT sherwinkylej compliancewithwristwornaccelerometersinprimiparousearlypostpartumwomen
AT mosswhitneyd compliancewithwristwornaccelerometersinprimiparousearlypostpartumwomen
AT nygaardingride compliancewithwristwornaccelerometersinprimiparousearlypostpartumwomen
AT eggermarlenej compliancewithwristwornaccelerometersinprimiparousearlypostpartumwomen
AT brusseautimothya compliancewithwristwornaccelerometersinprimiparousearlypostpartumwomen
AT shawjanetm compliancewithwristwornaccelerometersinprimiparousearlypostpartumwomen