Cargando…
Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials
BACKGROUND: Microaspiration of secretions around the tracheal cuff is a multifactorial process. Tracheal cuff shape might take a major part in its occurrence. The rationale for producing a taper-shaped cuff is established on the assumption that compared to a conventional cuff with a single fixed dia...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6362499/ https://www.ncbi.nlm.nih.gov/pubmed/30805066 http://dx.doi.org/10.1155/2019/7876417 |
_version_ | 1783392931186475008 |
---|---|
author | Huang, Wei Min Huang, Xu An Du, Yan Ping Li, Liu Xia Wu, Fang Fang Hong, Shao Qing Tang, Fang Xuan Ye, Zhang Qiang |
author_facet | Huang, Wei Min Huang, Xu An Du, Yan Ping Li, Liu Xia Wu, Fang Fang Hong, Shao Qing Tang, Fang Xuan Ye, Zhang Qiang |
author_sort | Huang, Wei Min |
collection | PubMed |
description | BACKGROUND: Microaspiration of secretions around the tracheal cuff is a multifactorial process. Tracheal cuff shape might take a major part in its occurrence. The rationale for producing a taper-shaped cuff is established on the assumption that compared to a conventional cuff with a single fixed diameter, a continuum of minimum-to-maximum diameter sections might better fit the tracheal walls. OBJECTIVES: The primary objective of this meta-analysis was to compare ventilator-associated pneumonia (VAP) between tapered-cuff intubation and conventional-cuff intubation. The secondary objective was to compare intensive care unit (ICU) mortality between tapered-cuff intubation and conventional-cuff intubation. METHODS: We searched the Cochrane Library, Embase, MEDLINE database through the PubMed search engine, and CINAHL from inception to April 2018. Randomized trials comparing VAP and ICU mortality between tapered-cuff intubation and conventional-cuff intubation in intubated adults were included. Two review authors assessed study quality and abstracted databasing on prespecified criteria independently. RESULTS: We pooled summary estimates from 5 trials evaluating tapered-cuff involving 774 participants. Compared to VAP, no statistically significant difference was observed between the tapered-cuff and conventional-cuff groups (OR 0.82, CI 0.61–1.12, z = 1.24, and p=0.21). No statistically significant difference was observed between the tapered-cuff and conventional-cuff groups with ICU mortality (OR 0.77, CI 0.55–1.08, z = 1.49, and p=0.14). CONCLUSIONS: In this meta-analysis, the tapered-cuff tracheal tube may not be superior to the standard-cuff tracheal tube in reducing VAP and ICU mortality. |
format | Online Article Text |
id | pubmed-6362499 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-63624992019-02-25 Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials Huang, Wei Min Huang, Xu An Du, Yan Ping Li, Liu Xia Wu, Fang Fang Hong, Shao Qing Tang, Fang Xuan Ye, Zhang Qiang Can Respir J Review Article BACKGROUND: Microaspiration of secretions around the tracheal cuff is a multifactorial process. Tracheal cuff shape might take a major part in its occurrence. The rationale for producing a taper-shaped cuff is established on the assumption that compared to a conventional cuff with a single fixed diameter, a continuum of minimum-to-maximum diameter sections might better fit the tracheal walls. OBJECTIVES: The primary objective of this meta-analysis was to compare ventilator-associated pneumonia (VAP) between tapered-cuff intubation and conventional-cuff intubation. The secondary objective was to compare intensive care unit (ICU) mortality between tapered-cuff intubation and conventional-cuff intubation. METHODS: We searched the Cochrane Library, Embase, MEDLINE database through the PubMed search engine, and CINAHL from inception to April 2018. Randomized trials comparing VAP and ICU mortality between tapered-cuff intubation and conventional-cuff intubation in intubated adults were included. Two review authors assessed study quality and abstracted databasing on prespecified criteria independently. RESULTS: We pooled summary estimates from 5 trials evaluating tapered-cuff involving 774 participants. Compared to VAP, no statistically significant difference was observed between the tapered-cuff and conventional-cuff groups (OR 0.82, CI 0.61–1.12, z = 1.24, and p=0.21). No statistically significant difference was observed between the tapered-cuff and conventional-cuff groups with ICU mortality (OR 0.77, CI 0.55–1.08, z = 1.49, and p=0.14). CONCLUSIONS: In this meta-analysis, the tapered-cuff tracheal tube may not be superior to the standard-cuff tracheal tube in reducing VAP and ICU mortality. Hindawi 2019-01-22 /pmc/articles/PMC6362499/ /pubmed/30805066 http://dx.doi.org/10.1155/2019/7876417 Text en Copyright © 2019 Wei Min Huang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Huang, Wei Min Huang, Xu An Du, Yan Ping Li, Liu Xia Wu, Fang Fang Hong, Shao Qing Tang, Fang Xuan Ye, Zhang Qiang Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials |
title | Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials |
title_full | Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials |
title_fullStr | Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials |
title_full_unstemmed | Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials |
title_short | Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials |
title_sort | tapered cuff versus conventional cuff for ventilator-associated pneumonia in ventilated patients: a meta-analysis of randomized controlled trials |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6362499/ https://www.ncbi.nlm.nih.gov/pubmed/30805066 http://dx.doi.org/10.1155/2019/7876417 |
work_keys_str_mv | AT huangweimin taperedcuffversusconventionalcuffforventilatorassociatedpneumoniainventilatedpatientsametaanalysisofrandomizedcontrolledtrials AT huangxuan taperedcuffversusconventionalcuffforventilatorassociatedpneumoniainventilatedpatientsametaanalysisofrandomizedcontrolledtrials AT duyanping taperedcuffversusconventionalcuffforventilatorassociatedpneumoniainventilatedpatientsametaanalysisofrandomizedcontrolledtrials AT liliuxia taperedcuffversusconventionalcuffforventilatorassociatedpneumoniainventilatedpatientsametaanalysisofrandomizedcontrolledtrials AT wufangfang taperedcuffversusconventionalcuffforventilatorassociatedpneumoniainventilatedpatientsametaanalysisofrandomizedcontrolledtrials AT hongshaoqing taperedcuffversusconventionalcuffforventilatorassociatedpneumoniainventilatedpatientsametaanalysisofrandomizedcontrolledtrials AT tangfangxuan taperedcuffversusconventionalcuffforventilatorassociatedpneumoniainventilatedpatientsametaanalysisofrandomizedcontrolledtrials AT yezhangqiang taperedcuffversusconventionalcuffforventilatorassociatedpneumoniainventilatedpatientsametaanalysisofrandomizedcontrolledtrials |