Cargando…

RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY

OBJECTIVE: To evaluate the radiation dose received by staff in spine surgeries, including those who are not considered occupationally exposed workers. METHODS: All spinal surgeries performed in the same department during a period of 12 months were evaluated with regard to the exposure of surgeons, s...

Descripción completa

Detalles Bibliográficos
Autores principales: Cristante, Alexandre Fogaça, Barbieri, Fábio, da Silva, Almy Anacleto Rodrigues, Dellamano, José Claudio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: ATHA EDITORA 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6362693/
https://www.ncbi.nlm.nih.gov/pubmed/30774530
http://dx.doi.org/10.1590/1413-785220192701172722
_version_ 1783392977837621248
author Cristante, Alexandre Fogaça
Barbieri, Fábio
da Silva, Almy Anacleto Rodrigues
Dellamano, José Claudio
author_facet Cristante, Alexandre Fogaça
Barbieri, Fábio
da Silva, Almy Anacleto Rodrigues
Dellamano, José Claudio
author_sort Cristante, Alexandre Fogaça
collection PubMed
description OBJECTIVE: To evaluate the radiation dose received by staff in spine surgeries, including those who are not considered occupationally exposed workers. METHODS: All spinal surgeries performed in the same department during a period of 12 months were evaluated with regard to the exposure of surgeons, scrub nurses, and auxiliary personnel working in the operating room to radiation from C-arm fluoroscopy. Radiation was measured by 15 film badge dosimeters placed on the professionals’ lapels, gloves, and room standardized sites. The films were analyzed in the dosimetry laboratory by collections per period. RESULTS: During the 12 months, 81 spinal surgeries were performed by the same team, with surgical times ranging from 1 to 6 hours. The total radiation dose ranged from 0.16 mSv to 2.29 mSv depending on the dosimetry site. The most exposed site was the wrist of the main surgeon. CONCLUSION: The results showed that in the spinal surgeries in our setting, the radiation doses are low and within legal limits. Nevertheless, constant training of professionals is essential for radiation protection of medical staff and patients. Level of evidence I/b, exploratory cohort study.
format Online
Article
Text
id pubmed-6362693
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher ATHA EDITORA
record_format MEDLINE/PubMed
spelling pubmed-63626932019-02-15 RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY Cristante, Alexandre Fogaça Barbieri, Fábio da Silva, Almy Anacleto Rodrigues Dellamano, José Claudio Acta Ortop Bras Original Article OBJECTIVE: To evaluate the radiation dose received by staff in spine surgeries, including those who are not considered occupationally exposed workers. METHODS: All spinal surgeries performed in the same department during a period of 12 months were evaluated with regard to the exposure of surgeons, scrub nurses, and auxiliary personnel working in the operating room to radiation from C-arm fluoroscopy. Radiation was measured by 15 film badge dosimeters placed on the professionals’ lapels, gloves, and room standardized sites. The films were analyzed in the dosimetry laboratory by collections per period. RESULTS: During the 12 months, 81 spinal surgeries were performed by the same team, with surgical times ranging from 1 to 6 hours. The total radiation dose ranged from 0.16 mSv to 2.29 mSv depending on the dosimetry site. The most exposed site was the wrist of the main surgeon. CONCLUSION: The results showed that in the spinal surgeries in our setting, the radiation doses are low and within legal limits. Nevertheless, constant training of professionals is essential for radiation protection of medical staff and patients. Level of evidence I/b, exploratory cohort study. ATHA EDITORA 2019 /pmc/articles/PMC6362693/ /pubmed/30774530 http://dx.doi.org/10.1590/1413-785220192701172722 Text en https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Cristante, Alexandre Fogaça
Barbieri, Fábio
da Silva, Almy Anacleto Rodrigues
Dellamano, José Claudio
RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY
title RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY
title_full RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY
title_fullStr RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY
title_full_unstemmed RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY
title_short RADIATION EXPOSURE DURING SPINE SURGERY USING C-ARM FLUOROSCOPY
title_sort radiation exposure during spine surgery using c-arm fluoroscopy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6362693/
https://www.ncbi.nlm.nih.gov/pubmed/30774530
http://dx.doi.org/10.1590/1413-785220192701172722
work_keys_str_mv AT cristantealexandrefogaca radiationexposureduringspinesurgeryusingcarmfluoroscopy
AT barbierifabio radiationexposureduringspinesurgeryusingcarmfluoroscopy
AT dasilvaalmyanacletorodrigues radiationexposureduringspinesurgeryusingcarmfluoroscopy
AT dellamanojoseclaudio radiationexposureduringspinesurgeryusingcarmfluoroscopy