Cargando…

Bone mineral density assessment for research purpose using dual energy X-ray absorptiometry

Dual energy X-ray absorptiometry (DXA) has become the most common method for measuring bone mineral density (BMD) of small animals in metabolic bone disease research, and errors should be minimized in all procedures involved in research studies in order to increase the accuracy of the study results....

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Ho Sung, Jeong, Eun Sun, Yang, Myung Hwa, Yang, Seoung-Oh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Osteoporosis 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6362959/
https://www.ncbi.nlm.nih.gov/pubmed/30775548
http://dx.doi.org/10.1016/j.afos.2018.09.003
_version_ 1783393030956384256
author Kim, Ho Sung
Jeong, Eun Sun
Yang, Myung Hwa
Yang, Seoung-Oh
author_facet Kim, Ho Sung
Jeong, Eun Sun
Yang, Myung Hwa
Yang, Seoung-Oh
author_sort Kim, Ho Sung
collection PubMed
description Dual energy X-ray absorptiometry (DXA) has become the most common method for measuring bone mineral density (BMD) of small animals in metabolic bone disease research, and errors should be minimized in all procedures involved in research studies in order to increase the accuracy of the study results. DXA is simpler and rapid compared to micro-computed tomography for quantitative analysis of change in trabecular bone of test subject. In human research, measuring BMD is widely used; postoperative evaluation on orthopedic surgery, evaluation of osteoporosis medication in menopause and many other areas of study. For the study, the inspector should be trained by the equipment manufacturer regarding the utilization and analysis of the equipment and regular phantom testing should be conducted to ensure the stability of the equipment, and precision tests should be conducted to analyze the positioning and data analysis. They should also be familiar with the clinical trials and conduct studies based on the approval of the Institutional Review Board. In the absolute BMD measurement of the human body, it is necessary to apply and compare the position and condition, rotation degree, region of interest, and area of the scan in the follow-up test. In the case of small animals, animal selection, measurement and equipment should be modeled to match the research. Therefore, we would like to provide information for researchers to minimize the errors, effective data management and accurate data presentation. This article reviews the process of DXA measurement for research purpose including plan for DXA examination, BMD measurement in a human body study and small animal studies.
format Online
Article
Text
id pubmed-6362959
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Society of Osteoporosis
record_format MEDLINE/PubMed
spelling pubmed-63629592019-02-15 Bone mineral density assessment for research purpose using dual energy X-ray absorptiometry Kim, Ho Sung Jeong, Eun Sun Yang, Myung Hwa Yang, Seoung-Oh Osteoporos Sarcopenia Review Article Dual energy X-ray absorptiometry (DXA) has become the most common method for measuring bone mineral density (BMD) of small animals in metabolic bone disease research, and errors should be minimized in all procedures involved in research studies in order to increase the accuracy of the study results. DXA is simpler and rapid compared to micro-computed tomography for quantitative analysis of change in trabecular bone of test subject. In human research, measuring BMD is widely used; postoperative evaluation on orthopedic surgery, evaluation of osteoporosis medication in menopause and many other areas of study. For the study, the inspector should be trained by the equipment manufacturer regarding the utilization and analysis of the equipment and regular phantom testing should be conducted to ensure the stability of the equipment, and precision tests should be conducted to analyze the positioning and data analysis. They should also be familiar with the clinical trials and conduct studies based on the approval of the Institutional Review Board. In the absolute BMD measurement of the human body, it is necessary to apply and compare the position and condition, rotation degree, region of interest, and area of the scan in the follow-up test. In the case of small animals, animal selection, measurement and equipment should be modeled to match the research. Therefore, we would like to provide information for researchers to minimize the errors, effective data management and accurate data presentation. This article reviews the process of DXA measurement for research purpose including plan for DXA examination, BMD measurement in a human body study and small animal studies. Korean Society of Osteoporosis 2018-09 2018-09-27 /pmc/articles/PMC6362959/ /pubmed/30775548 http://dx.doi.org/10.1016/j.afos.2018.09.003 Text en © 2018 The Korean Society of Osteoporosis. Publishing services by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Review Article
Kim, Ho Sung
Jeong, Eun Sun
Yang, Myung Hwa
Yang, Seoung-Oh
Bone mineral density assessment for research purpose using dual energy X-ray absorptiometry
title Bone mineral density assessment for research purpose using dual energy X-ray absorptiometry
title_full Bone mineral density assessment for research purpose using dual energy X-ray absorptiometry
title_fullStr Bone mineral density assessment for research purpose using dual energy X-ray absorptiometry
title_full_unstemmed Bone mineral density assessment for research purpose using dual energy X-ray absorptiometry
title_short Bone mineral density assessment for research purpose using dual energy X-ray absorptiometry
title_sort bone mineral density assessment for research purpose using dual energy x-ray absorptiometry
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6362959/
https://www.ncbi.nlm.nih.gov/pubmed/30775548
http://dx.doi.org/10.1016/j.afos.2018.09.003
work_keys_str_mv AT kimhosung bonemineraldensityassessmentforresearchpurposeusingdualenergyxrayabsorptiometry
AT jeongeunsun bonemineraldensityassessmentforresearchpurposeusingdualenergyxrayabsorptiometry
AT yangmyunghwa bonemineraldensityassessmentforresearchpurposeusingdualenergyxrayabsorptiometry
AT yangseoungoh bonemineraldensityassessmentforresearchpurposeusingdualenergyxrayabsorptiometry