Cargando…

Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test

BACKGROUND: This experimental study assessed reverse torque of indexed and nonindexed (NI) abutments in Morse Taper (MT) implants in a mechanical fatigue test. MATERIALS AND METHODS: In this experimental study It was used 37 implants MT and over them installed Pilar Flex abutments (4.8 mm × 6 mm × 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Martins, Caio Marques, Ramos, Elimário Venturin, Kreve, Simone, de Carvalho, Geraldo Alberto Pinheiro, Franco, Aline Batista Gonçalves, de Macedo, Luís Guilherme Scavone, Silva, Alecsandro de Moura, Dias, Sérgio Candido
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6364348/
https://www.ncbi.nlm.nih.gov/pubmed/30820205
_version_ 1783393250046902272
author Martins, Caio Marques
Ramos, Elimário Venturin
Kreve, Simone
de Carvalho, Geraldo Alberto Pinheiro
Franco, Aline Batista Gonçalves
de Macedo, Luís Guilherme Scavone
Silva, Alecsandro de Moura
Dias, Sérgio Candido
author_facet Martins, Caio Marques
Ramos, Elimário Venturin
Kreve, Simone
de Carvalho, Geraldo Alberto Pinheiro
Franco, Aline Batista Gonçalves
de Macedo, Luís Guilherme Scavone
Silva, Alecsandro de Moura
Dias, Sérgio Candido
author_sort Martins, Caio Marques
collection PubMed
description BACKGROUND: This experimental study assessed reverse torque of indexed and nonindexed (NI) abutments in Morse Taper (MT) implants in a mechanical fatigue test. MATERIALS AND METHODS: In this experimental study It was used 37 implants MT and over them installed Pilar Flex abutments (4.8 mm × 6 mm × 1.5 mm). The groups were as follows: Group A used 19 MT implants with a NI Pilar Flex abutment loaded with 32 N/cm and Group B used 18 MT implants with an indexed (IN) Pilar Flex abutment loaded with 20 N/cm. The abutments were tested according to ISO standard 14801/2007. The specimens were installed at 30° from the axial axis and underwent a 133 N load, 4 Hz frequency, and 1,000,000 cycles. Once the test was completed, the reverse torque was provided by an electronic torque meter. Data were submitted to statistical analysis using the t-test for independent samples and paired t-test. The significance level was considered P < 0.05. RESULTS: Results obtained showed that the indexed Pilar Flex abutment had a percentage of torque loss from the initial torque of 49% and the NI Pilar Flex abutment lost 14%. Paired Student's t-tests revealed that for both NI (P < 0.001) and indexed (P < 0.001) abutments, the counter torque values were significantly lower than those applied at the initial torque. CONCLUSION: According on the methodology used, the NI Pilar Flex abutment was more effective regarding the reverse torque in single-unit implant prostheses versus the indexed Pilar Flex abutment. A greater loosening in the indexed Pilar Flex abutment retaining screw was noted in the reverse torque test, and the Pilar Flex abutment failed to show good outcomes related to the cold welding effect.
format Online
Article
Text
id pubmed-6364348
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-63643482019-03-01 Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test Martins, Caio Marques Ramos, Elimário Venturin Kreve, Simone de Carvalho, Geraldo Alberto Pinheiro Franco, Aline Batista Gonçalves de Macedo, Luís Guilherme Scavone Silva, Alecsandro de Moura Dias, Sérgio Candido Dent Res J (Isfahan) Original Article BACKGROUND: This experimental study assessed reverse torque of indexed and nonindexed (NI) abutments in Morse Taper (MT) implants in a mechanical fatigue test. MATERIALS AND METHODS: In this experimental study It was used 37 implants MT and over them installed Pilar Flex abutments (4.8 mm × 6 mm × 1.5 mm). The groups were as follows: Group A used 19 MT implants with a NI Pilar Flex abutment loaded with 32 N/cm and Group B used 18 MT implants with an indexed (IN) Pilar Flex abutment loaded with 20 N/cm. The abutments were tested according to ISO standard 14801/2007. The specimens were installed at 30° from the axial axis and underwent a 133 N load, 4 Hz frequency, and 1,000,000 cycles. Once the test was completed, the reverse torque was provided by an electronic torque meter. Data were submitted to statistical analysis using the t-test for independent samples and paired t-test. The significance level was considered P < 0.05. RESULTS: Results obtained showed that the indexed Pilar Flex abutment had a percentage of torque loss from the initial torque of 49% and the NI Pilar Flex abutment lost 14%. Paired Student's t-tests revealed that for both NI (P < 0.001) and indexed (P < 0.001) abutments, the counter torque values were significantly lower than those applied at the initial torque. CONCLUSION: According on the methodology used, the NI Pilar Flex abutment was more effective regarding the reverse torque in single-unit implant prostheses versus the indexed Pilar Flex abutment. A greater loosening in the indexed Pilar Flex abutment retaining screw was noted in the reverse torque test, and the Pilar Flex abutment failed to show good outcomes related to the cold welding effect. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6364348/ /pubmed/30820205 Text en Copyright: © 2019 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Martins, Caio Marques
Ramos, Elimário Venturin
Kreve, Simone
de Carvalho, Geraldo Alberto Pinheiro
Franco, Aline Batista Gonçalves
de Macedo, Luís Guilherme Scavone
Silva, Alecsandro de Moura
Dias, Sérgio Candido
Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test
title Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test
title_full Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test
title_fullStr Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test
title_full_unstemmed Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test
title_short Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test
title_sort reverse torque evaluation in indexed and nonindexed abutments of morse taper implants in a mechanical fatigue test
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6364348/
https://www.ncbi.nlm.nih.gov/pubmed/30820205
work_keys_str_mv AT martinscaiomarques reversetorqueevaluationinindexedandnonindexedabutmentsofmorsetaperimplantsinamechanicalfatiguetest
AT ramoselimarioventurin reversetorqueevaluationinindexedandnonindexedabutmentsofmorsetaperimplantsinamechanicalfatiguetest
AT krevesimone reversetorqueevaluationinindexedandnonindexedabutmentsofmorsetaperimplantsinamechanicalfatiguetest
AT decarvalhogeraldoalbertopinheiro reversetorqueevaluationinindexedandnonindexedabutmentsofmorsetaperimplantsinamechanicalfatiguetest
AT francoalinebatistagoncalves reversetorqueevaluationinindexedandnonindexedabutmentsofmorsetaperimplantsinamechanicalfatiguetest
AT demacedoluisguilhermescavone reversetorqueevaluationinindexedandnonindexedabutmentsofmorsetaperimplantsinamechanicalfatiguetest
AT silvaalecsandrodemoura reversetorqueevaluationinindexedandnonindexedabutmentsofmorsetaperimplantsinamechanicalfatiguetest
AT diassergiocandido reversetorqueevaluationinindexedandnonindexedabutmentsofmorsetaperimplantsinamechanicalfatiguetest